<?xml version="1.0" encoding="utf-8"?>
<?xml-stylesheet href="ipcentry.xsl" type="text/xsl"?>
<ipcEntries displayMode="e20080401;a20080401;c20060101" ipcLevel="a" split="subclass" languages=",en,fr," size="65460">
	<ipcEntry kind="s" symbol="H" ipcLevel="C" entryType="K" lang="EN" nocore="yes">
		<textBody>
			<title>
				<titlePart>
					<text>SECTION H <emdash/> ELECTRICITY</text>
				</titlePart>
			</title>
		</textBody>
		<ipcEntry kind="n" symbol="H" ipcLevel="C" entryType="K" lang="EN" nocore="yes">
			<textBody>
				<note type="none">
					<noteParagraph>
						<text>These Notes cover the basic principles and general instructions for use of section H.</text>
						<subnote type="Roman" indent="1">
							<noteParagraph>
								<text>Section H <u>covers</u>:</text>
								<subnote type="alpha" indent="2">
									<noteParagraph>
										<text>basic electric elements, which cover all electric units and the general mechanical structure of apparatus and circuits, including the assembly of various basic elements into what are called printed circuits and also cover to a certain extent the manufacture of these elements (when not covered elsewhere);</text>
									</noteParagraph>
									<noteParagraph>
										<text>generation of electricity, which covers the generation, conversion and distribution of electricity together with the controlling of the corresponding gear;</text>
									</noteParagraph>
									<noteParagraph>
										<text>applied electricity, which <u>covers</u>:</text>
										<subnote type="roman" indent="3">
											<noteParagraph>
												<text>general utilisation techniques, viz. those of electric heating and electric lighting circuits;</text>
											</noteParagraph>
											<noteParagraph>
												<text>some special utilisation techniques, either electric or electronic in the strict sense, which are not covered by other sections of the Classification, including:</text>
												<subnote type="number" indent="4">
													<noteParagraph>
														<text>electric light sources, including lasers;</text>
													</noteParagraph>
													<noteParagraph>
														<text>electric X-ray technique;</text>
													</noteParagraph>
													<noteParagraph>
														<text>electric plasma technique and the generation and acceleration of electrically charged particles or neutrons;</text>
													</noteParagraph>
												</subnote>
											</noteParagraph>
										</subnote>
									</noteParagraph>
									<noteParagraph>
										<text>basic electronic circuits and their control;</text>
									</noteParagraph>
									<noteParagraph>
										<text>radio or electric communication technique;</text>
									</noteParagraph>
									<noteParagraph>
										<text>the use of a specified material for the manufacture of the article or element described. In this connection, paragraphs<nbsp/>88 to<nbsp/>90 of the Guide should be referred to.</text>
									</noteParagraph>
								</subnote>
							</noteParagraph>
							<noteParagraph>
								<text>In this section, the following general rules apply: </text>
								<subnote type="alpha" indent="2">
									<noteParagraph>
										<text>Subject to the exceptions stated in I(c), above, any electric aspect or part peculiar to a particular operation, process, apparatus, object or article, classified in one of the sections of the Classification other than section H, is always classified in the subclass for that operation, process, apparatus, object or article. Where common characteristics concerning technical subjects of similar nature have been brought out at class level, the electric aspect or part is classified, in conjunction with the operation, process, apparatus, object or article, in a subclass which covers entirely the general electrical applications for the technical subject in question;</text>
									</noteParagraph>
									<noteParagraph>
										<text>The electrical applications referred to under (a), above, either general or particular, include:</text>
										<subnote type="roman" indent="3">
											<noteParagraph>
												<text>the therapeutic processes and apparatus, in class <sref ref="A61"/>;</text>
											</noteParagraph>
											<noteParagraph>
												<text>the electric processes and apparatus used in various laboratory or industrial operations, in classes <sref ref="B01"/> and <sref ref="B03"/> and in subclass <sref ref="B23K"/>;</text>
											</noteParagraph>
											<noteParagraph>
												<text>the electricity supply, electric propulsion and electric lighting of vehicles in general and of particular vehicles, in the subsection "Transporting" of section B;</text>
											</noteParagraph>
											<noteParagraph>
												<text>the electric ignition systems of internal-combustion engines, in subclass <sref ref="F02P"/>, and of combustion apparatus in general, in subclass <sref ref="F23Q"/>;</text>
											</noteParagraph>
											<noteParagraph>
												<text>the whole electrical part of section G, i.e. measuring devices including apparatus for measuring electric variables, checking, signalling and calculating. Electricity in that section is generally dealt with as a means and not as an end in itself;</text>
											</noteParagraph>
										</subnote>
									</noteParagraph>
									<noteParagraph>
										<text>All electrical applications, both general and particular, presuppose that the "basic electricity" aspect appears in section H (see I(a) above) as regards the electric "basic elements" which they comprise. This rule is also valid for applied electricity, referred to in I(c), above, which appears in section H itself.</text>
									</noteParagraph>
								</subnote>
							</noteParagraph>
							<noteParagraph>
								<text>In this section, the following special cases occur: </text>
								<subnote type="alpha" indent="2">
									<noteParagraph>
										<text>Among the general applications covered by sections other than section H, it is worth noting that electric heating in general is covered by subclasses <sref ref="F24D"/> or <sref ref="F24H"/> or class <sref ref="F27"/>, and that electric lighting in general is partly covered by class <sref ref="F21"/>, since in section H (see I(c), above) there are places in <sref ref="H05B"/> which cover the same technical subjects;</text>
									</noteParagraph>
									<noteParagraph>
										<text>In the two cases referred to under (a), above, the subclasses of section F, which deal with the respective subjects, essentially cover in the first place the whole mechanical aspect of the apparatus or devices, whereas the electrical aspect, as such, is covered by subclass <sref ref="H05B"/>;</text>
									</noteParagraph>
									<noteParagraph>
										<text>In the case of lighting, this mechanical aspect should be taken to cover the material arrangement of the various electric elements, i.e., their geometrical or physical position in relation to one another; this aspect is covered by subclass <sref ref="F21V"/>, the elements themselves and the primary circuits remaining in section H. The same applies to electric light sources, when combined with light sources of a different kind. These are covered by subclass <sref ref="H05B"/>, whereas the physical arrangement which their combination constitutes is covered by the various subclasses of class <sref ref="F21"/>;</text>
									</noteParagraph>
									<noteParagraph>
										<text>As regards heating, not only the electric elements and circuitry designs, as such, are covered by subclass <sref ref="H05B"/>, but also the electric aspects of their arrangement, where these concern cases of general application; electric furnaces being considered as such. The physical disposition of the electric elements in furnaces is covered by section F. If a comparison is made with electric welding circuits, which are covered by subclass <sref ref="B23K"/> in connection with welding, it can be seen that electric heating is not covered by the general rule stated in II, above.</text>
									</noteParagraph>
								</subnote>
							</noteParagraph>
						</subnote>
					</noteParagraph>
				</note>
			</textBody>
		</ipcEntry>
		<ipcEntry kind="c" symbol="H02" ipcLevel="C" entryType="K" lang="EN" nocore="yes">
			<textBody>
				<title>
					<titlePart>
						<text>GENERATION, CONVERSION, OR DISTRIBUTION OF ELECTRIC POWER</text>
					</titlePart>
				</title>
			</textBody>
			<ipcEntry kind="u" symbol="H02J" ipcLevel="C" entryType="K" lang="EN" nocore="yes">
				<textBody>
					<title>
						<titlePart>
							<text>CIRCUIT ARRANGEMENTS OR SYSTEMS FOR SUPPLYING OR DISTRIBUTING ELECTRIC POWER</text>
						</titlePart>
						<titlePart>
							<text>SYSTEMS FOR STORING ELECTRIC ENERGY</text>
							<entryReference>power supply circuits for apparatus for measuring X-radiation, gamma radiation, corpuscular radiation or cosmic radiation <sref ref="G01T0001175000"/></entryReference>
							<entryReference>electric power supply circuits specially adapted for use in electronic time-pieces with no moving parts <sref ref="G04G0019000000"/></entryReference>
							<entryReference>for digital computers <sref ref="G06F0001180000"/></entryReference>
							<entryReference>for discharge tubes <sref ref="H01J0037248000"/></entryReference>
							<entryReference>circuits or apparatus for the conversion of electric power, arrangements for control or regulation of such circuits or apparatus <sref ref="H02M"/></entryReference>
							<entryReference>interrelated control of several motors, control of a prime-mover/generator combination <sref ref="H02P"/></entryReference>
							<entryReference>control of high-frequency power <sref ref="H03L"/></entryReference>
							<entryReference>additional use of power line or power network for transmission of information <sref ref="H04B"/></entryReference>
						</titlePart>
					</title>
				</textBody>
				<ipcEntry kind="n" symbol="H02J" ipcLevel="C" entryType="K" lang="EN" nocore="yes">
					<textBody>
						<note type="number">
							<noteParagraph>
								<text>This subclass <u>covers</u>:</text>
								<subnote type="bullet">
									<noteParagraph>
										<text>ac or dc mains or distribution networks;</text>
									</noteParagraph>
									<noteParagraph>
										<text>circuit arrangements for battery supplies, including charging or control thereof, or co-ordinated supply from two or more sources of any kind;</text>
									</noteParagraph>
									<noteParagraph>
										<text>systems for supplying or distributing electric power by electromagnetic waves.</text>
									</noteParagraph>
								</subnote>
							</noteParagraph>
							<noteParagraph>
								<text>This subclass <u>does not cover</u>:</text>
								<subnote type="bullet">
									<noteParagraph>
										<text>control of a single motor, generator or dynamo-electric converter, of the types covered by subclass <sref ref="H01F"/> or <sref ref="H02K"/>, which is covered by subclass <sref ref="H02P"/>;</text>
									</noteParagraph>
									<noteParagraph>
										<text>control of a single motor or generator, of the types covered by subclass <sref ref="H02N"/>, which is covered by that subclass.</text>
									</noteParagraph>
								</subnote>
							</noteParagraph>
						</note>
					</textBody>
				</ipcEntry>
				<ipcEntry kind="i" symbol="H02J" ipcLevel="C" entryType="K" lang="EN" nocore="yes">
					<textBody>
						<index>
							<indexEntry>
								<text>CIRCUIT ARRANGEMENTS</text>
								<indexEntry>
									<text>For distribution networks:</text>
									<indexEntry>
										<text>direct current; alternative current </text>
										<references><sref ref="H02J0001000000"/>; <sref ref="H02J0003000000"/></references>
									</indexEntry>
									<indexEntry>
										<text>combined; not specified </text>
										<references><sref ref="H02J0005000000"/>; <sref ref="H02J0004000000"/></references>
									</indexEntry>
								</indexEntry>
								<indexEntry>
									<text>For batteries </text>
									<references><sref ref="H02J0007000000"/></references>
								</indexEntry>
								<indexEntry>
									<text>For emergency or stand-by power supply </text>
									<references><sref ref="H02J0009000000"/></references>
								</indexEntry>
								<indexEntry>
									<text>For power supply to auxiliaries of stations </text>
									<references><sref ref="H02J0011000000"/></references>
								</indexEntry>
								<indexEntry>
									<text>For providing remote indication of network conditions </text>
									<references><sref ref="H02J0013000000"/></references>
								</indexEntry>
							</indexEntry>
							<indexEntry>
								<text>SYSTEMS FOR STORING ELECTRICAL ENERGY </text>
								<references><sref ref="H02J0015000000"/></references>
							</indexEntry>
							<indexEntry>
								<text>SYSTEMS FOR POWER DISTRIBUTION BY ELECTROMAGNETIC WAVES </text>
								<references><sref ref="H02J0017000000"/></references>
							</indexEntry>
						</index>
					</textBody>
				</ipcEntry>
				<ipcEntry kind="m" symbol="H02J0001000000" ipcLevel="C" entryType="K" lang="EN" priorityOrder="30" nocore="yes">
					<textBody>
						<title>
							<titlePart>
								<text>Circuit arrangements for dc mains or dc distribution networks</text>
							</titlePart>
						</title>
					</textBody>
					<ipcEntry kind="1" symbol="H02J0001020000" ipcLevel="C" entryType="K" lang="EN" nocore="yes">
						<textBody>
							<title>
								<titlePart>
									<text>Arrangements for reducing harmonics or ripples</text>
									<entryReference>in converters <sref ref="H02M0001140000"/></entryReference>
								</titlePart>
							</title>
						</textBody>
					</ipcEntry>
					<ipcEntry kind="1" symbol="H02J0001040000" ipcLevel="C" entryType="K" lang="EN" nocore="yes">
						<textBody>
							<title>
								<titlePart>
									<text>Constant-current supply systems</text>
								</titlePart>
							</title>
						</textBody>
					</ipcEntry>
					<ipcEntry kind="1" symbol="H02J0001060000" ipcLevel="C" entryType="K" lang="EN" nocore="yes">
						<textBody>
							<title>
								<titlePart>
									<text>Two-wire systems</text>
								</titlePart>
							</title>
						</textBody>
					</ipcEntry>
					<ipcEntry kind="1" symbol="H02J0001080000" ipcLevel="C" entryType="K" lang="EN" nocore="yes">
						<textBody>
							<title>
								<titlePart>
									<text>Three-wire systems</text>
								</titlePart>
								<titlePart>
									<text>Systems having more than three wires</text>
								</titlePart>
							</title>
						</textBody>
					</ipcEntry>
					<ipcEntry kind="1" symbol="H02J0001100000" ipcLevel="C" entryType="K" lang="EN" nocore="yes">
						<textBody>
							<title>
								<titlePart>
									<text>Parallel operation of dc sources</text>
									<entryReference>involving batteries <sref ref="H02J0007340000"/></entryReference>
								</titlePart>
							</title>
						</textBody>
						<ipcEntry kind="2" symbol="H02J0001120000" ipcLevel="A" entryType="K" lang="EN" nocore="yes">
							<textBody>
								<title>
									<titlePart>
										<text>Parallel operation of dc generators with converters, e.g. with mercury-arc rectifier</text>
									</titlePart>
								</title>
							</textBody>
						</ipcEntry>
					</ipcEntry>
					<ipcEntry kind="1" symbol="H02J0001140000" ipcLevel="C" entryType="K" lang="EN" nocore="yes">
						<textBody>
							<title>
								<titlePart>
									<text>Balancing the load in a network</text>
									<entryReference>by batteries <sref ref="H02J0007340000"/></entryReference>
								</titlePart>
							</title>
						</textBody>
						<ipcEntry kind="2" symbol="H02J0001160000" ipcLevel="A" entryType="K" lang="EN" nocore="yes">
							<textBody>
								<title>
									<titlePart>
										<text>using dynamo-electric machines coupled to flywheels</text>
									</titlePart>
								</title>
							</textBody>
						</ipcEntry>
					</ipcEntry>
				</ipcEntry>
				<ipcEntry kind="m" symbol="H02J0003000000" ipcLevel="C" entryType="K" lang="EN" priorityOrder="20" nocore="yes">
					<textBody>
						<title>
							<titlePart>
								<text>Circuit arrangements for ac mains or ac distribution networks</text>
							</titlePart>
						</title>
					</textBody>
					<ipcEntry kind="1" symbol="H02J0003010000" ipcLevel="C" edition="19800101" entryType="K" lang="EN" nocore="yes">
						<textBody>
							<title>
								<titlePart>
									<text>Arrangements for reducing harmonics or ripples</text>
									<entryReference>in converters <sref ref="H02M0001120000"/></entryReference>
								</titlePart>
							</title>
						</textBody>
					</ipcEntry>
					<ipcEntry kind="1" symbol="H02J0003020000" ipcLevel="C" entryType="K" lang="EN" nocore="yes">
						<textBody>
							<title>
								<titlePart>
									<text>using a single network for simultaneous distribution of power at different frequencies</text>
								</titlePart>
								<titlePart>
									<text>using a single network for simultaneous distribution of ac power and of dc power</text>
								</titlePart>
							</title>
						</textBody>
					</ipcEntry>
					<ipcEntry kind="1" symbol="H02J0003040000" ipcLevel="C" entryType="K" lang="EN" nocore="yes">
						<textBody>
							<title>
								<titlePart>
									<text>for connecting networks of the same frequency but supplied from different sources</text>
								</titlePart>
							</title>
						</textBody>
						<ipcEntry kind="2" symbol="H02J0003060000" ipcLevel="A" entryType="K" lang="EN" nocore="yes">
							<textBody>
								<title>
									<titlePart>
										<text>Controlling transfer of power between connected networks</text>
									</titlePart>
									<titlePart>
										<text>Controlling sharing of load between connected networks</text>
									</titlePart>
								</title>
							</textBody>
						</ipcEntry>
						<ipcEntry kind="2" symbol="H02J0003080000" ipcLevel="A" entryType="K" lang="EN" nocore="yes">
							<textBody>
								<title>
									<titlePart>
										<text>Synchronising of networks</text>
									</titlePart>
								</title>
							</textBody>
						</ipcEntry>
					</ipcEntry>
					<ipcEntry kind="1" symbol="H02J0003100000" ipcLevel="C" entryType="K" lang="EN" nocore="yes">
						<textBody>
							<title>
								<titlePart>
									<text>Constant-current supply systems</text>
								</titlePart>
							</title>
						</textBody>
					</ipcEntry>
					<ipcEntry kind="1" symbol="H02J0003120000" ipcLevel="C" entryType="K" lang="EN" nocore="yes">
						<textBody>
							<title>
								<titlePart>
									<text>for adjusting voltage in ac networks by changing a characteristic of the network load</text>
								</titlePart>
							</title>
						</textBody>
						<ipcEntry kind="2" symbol="H02J0003140000" ipcLevel="A" entryType="K" lang="EN" nocore="yes">
							<textBody>
								<title>
									<titlePart>
										<text>by switching loads on to, or off from, network, e.g. progressively balanced loading</text>
									</titlePart>
								</title>
							</textBody>
						</ipcEntry>
						<ipcEntry kind="2" symbol="H02J0003160000" ipcLevel="A" entryType="K" lang="EN" nocore="yes">
							<textBody>
								<title>
									<titlePart>
										<text>by adjustment of reactive power</text>
									</titlePart>
								</title>
							</textBody>
						</ipcEntry>
					</ipcEntry>
					<ipcEntry kind="1" symbol="H02J0003180000" ipcLevel="C" entryType="K" lang="EN" nocore="yes">
						<textBody>
							<title>
								<titlePart>
									<text>Arrangements for adjusting, eliminating, or compensating reactive power in networks</text>
									<entryReference>for adjustment of voltage <sref ref="H02J0003120000"/></entryReference>
									<entryReference>use of Petersen coils <sref ref="H02H0009080000"/></entryReference>
								</titlePart>
							</title>
						</textBody>
						<ipcEntry kind="2" symbol="H02J0003200000" ipcLevel="A" entryType="K" lang="EN" nocore="yes">
							<textBody>
								<title>
									<titlePart>
										<text>in long overhead lines</text>
									</titlePart>
								</title>
							</textBody>
						</ipcEntry>
						<ipcEntry kind="2" symbol="H02J0003220000" ipcLevel="A" entryType="K" lang="EN" nocore="yes">
							<textBody>
								<title>
									<titlePart>
										<text>in cables</text>
									</titlePart>
								</title>
							</textBody>
						</ipcEntry>
					</ipcEntry>
					<ipcEntry kind="1" symbol="H02J0003240000" ipcLevel="C" entryType="K" lang="EN" nocore="yes">
						<textBody>
							<title>
								<titlePart>
									<text>Arrangements for preventing or reducing oscillations of power in networks</text>
									<entryReference>by control effected upon a single generator <sref ref="H02P0009000000"/></entryReference>
								</titlePart>
							</title>
						</textBody>
					</ipcEntry>
					<ipcEntry kind="1" symbol="H02J0003260000" ipcLevel="C" entryType="K" lang="EN" nocore="yes">
						<textBody>
							<title>
								<titlePart>
									<text>Arrangements for eliminating or reducing asymmetry in polyphase networks</text>
								</titlePart>
							</title>
						</textBody>
					</ipcEntry>
					<ipcEntry kind="1" symbol="H02J0003280000" ipcLevel="C" entryType="K" lang="EN" nocore="yes">
						<textBody>
							<title>
								<titlePart>
									<text>Arrangements for balancing the load in a network by storage of energy</text>
								</titlePart>
							</title>
						</textBody>
						<ipcEntry kind="2" symbol="H02J0003300000" ipcLevel="A" entryType="K" lang="EN" nocore="yes">
							<textBody>
								<title>
									<titlePart>
										<text>using dynamo-electric machines coupled to flywheels</text>
									</titlePart>
								</title>
							</textBody>
						</ipcEntry>
						<ipcEntry kind="2" symbol="H02J0003320000" ipcLevel="A" entryType="K" lang="EN" nocore="yes">
							<textBody>
								<title>
									<titlePart>
										<text>using batteries with converting means</text>
									</titlePart>
								</title>
							</textBody>
						</ipcEntry>
					</ipcEntry>
					<ipcEntry kind="1" symbol="H02J0003340000" ipcLevel="C" entryType="K" lang="EN" nocore="yes">
						<textBody>
							<title>
								<titlePart>
									<text>Arrangements for transfer of electric power between networks of substantially different frequency</text>
									<entryReference>frequency converters <sref ref="H02M"/></entryReference>
								</titlePart>
							</title>
						</textBody>
					</ipcEntry>
					<ipcEntry kind="1" symbol="H02J0003360000" ipcLevel="C" entryType="K" lang="EN" nocore="yes">
						<textBody>
							<title>
								<titlePart>
									<text>Arrangements for transfer of electric power between ac networks <u>via</u> a high-tension dc link</text>
								</titlePart>
							</title>
						</textBody>
					</ipcEntry>
					<ipcEntry kind="1" symbol="H02J0003380000" ipcLevel="C" entryType="K" lang="EN" nocore="yes">
						<textBody>
							<title>
								<titlePart>
									<text>Arrangements for parallelly feeding a single network by two or more generators, converters, or transformers</text>
								</titlePart>
							</title>
						</textBody>
						<ipcEntry kind="2" symbol="H02J0003400000" ipcLevel="C" entryType="K" lang="EN" nocore="yes">
							<textBody>
								<title>
									<titlePart>
										<text>Synchronising a generator for connection to a network or to another generator</text>
									</titlePart>
								</title>
							</textBody>
							<ipcEntry kind="3" symbol="H02J0003420000" ipcLevel="A" entryType="K" lang="EN" nocore="yes">
								<textBody>
									<title>
										<titlePart>
											<text>with automatic parallel connection when synchronism is achieved</text>
										</titlePart>
									</title>
								</textBody>
							</ipcEntry>
							<ipcEntry kind="3" symbol="H02J0003440000" ipcLevel="A" entryType="K" lang="EN" nocore="yes">
								<textBody>
									<title>
										<titlePart>
											<text>with means for ensuring correct phase sequence</text>
										</titlePart>
									</title>
								</textBody>
							</ipcEntry>
						</ipcEntry>
						<ipcEntry kind="2" symbol="H02J0003460000" ipcLevel="C" entryType="K" lang="EN" nocore="yes">
							<textBody>
								<title>
									<titlePart>
										<text>Controlling the sharing of output between the generators, converters, or transformers</text>
									</titlePart>
								</title>
							</textBody>
							<ipcEntry kind="3" symbol="H02J0003480000" ipcLevel="A" entryType="K" lang="EN" nocore="yes">
								<textBody>
									<title>
										<titlePart>
											<text>Controlling the sharing of the in-phase component</text>
										</titlePart>
									</title>
								</textBody>
							</ipcEntry>
							<ipcEntry kind="3" symbol="H02J0003500000" ipcLevel="A" entryType="K" lang="EN" nocore="yes">
								<textBody>
									<title>
										<titlePart>
											<text>Controlling the sharing of the out-of-phase component</text>
										</titlePart>
									</title>
								</textBody>
							</ipcEntry>
						</ipcEntry>
					</ipcEntry>
				</ipcEntry>
				<ipcEntry kind="m" symbol="H02J0004000000" ipcLevel="C" edition="19740701" entryType="K" lang="EN" priorityOrder="50" nocore="yes">
					<textBody>
						<title>
							<titlePart>
								<text>Circuit arrangements for mains or distribution networks not specified as ac or dc</text>
							</titlePart>
						</title>
					</textBody>
				</ipcEntry>
				<ipcEntry kind="m" symbol="H02J0005000000" ipcLevel="C" entryType="K" lang="EN" priorityOrder="40" nocore="yes">
					<textBody>
						<title>
							<titlePart>
								<text>Circuit arrangements for transfer of electric power between ac networks and dc networks</text>
								<entryReference><sref ref="H02J0003360000"/> takes precedence</entryReference>
							</titlePart>
						</title>
					</textBody>
				</ipcEntry>
				<ipcEntry kind="m" symbol="H02J0007000000" ipcLevel="C" entryType="K" lang="EN" priorityOrder="60" nocore="yes">
					<textBody>
						<title>
							<titlePart>
								<text>Circuit arrangements for charging or depolarising batteries or for supplying loads from batteries</text>
							</titlePart>
						</title>
					</textBody>
					<ipcEntry kind="1" symbol="H02J0007020000" ipcLevel="C" entryType="K" lang="EN" nocore="yes">
						<textBody>
							<title>
								<titlePart>
									<text>for charging batteries from ac mains by converters</text>
								</titlePart>
							</title>
						</textBody>
						<ipcEntry kind="2" symbol="H02J0007040000" ipcLevel="C" entryType="K" lang="EN" nocore="yes">
							<textBody>
								<title>
									<titlePart>
										<text>Regulation of the charging current or voltage</text>
									</titlePart>
								</title>
							</textBody>
							<ipcEntry kind="3" symbol="H02J0007060000" ipcLevel="C" entryType="K" lang="EN" nocore="yes">
								<textBody>
									<title>
										<titlePart>
											<text>using discharge tubes or semiconductor devices</text>
										</titlePart>
									</title>
								</textBody>
								<ipcEntry kind="4" symbol="H02J0007080000" ipcLevel="A" entryType="K" lang="EN" nocore="yes">
									<textBody>
										<title>
											<titlePart>
												<text>using discharge tubes only</text>
											</titlePart>
										</title>
									</textBody>
								</ipcEntry>
								<ipcEntry kind="4" symbol="H02J0007100000" ipcLevel="C" entryType="K" lang="EN" nocore="yes">
									<textBody>
										<title>
											<titlePart>
												<text>using semiconductor devices only</text>
											</titlePart>
										</title>
									</textBody>
								</ipcEntry>
							</ipcEntry>
							<ipcEntry kind="3" symbol="H02J0007120000" ipcLevel="C" entryType="K" lang="EN" nocore="yes">
								<textBody>
									<title>
										<titlePart>
											<text>using magnetic devices having controllable degree of saturation, i.e. transductors</text>
										</titlePart>
									</title>
								</textBody>
							</ipcEntry>
						</ipcEntry>
					</ipcEntry>
					<ipcEntry kind="1" symbol="H02J0007140000" ipcLevel="C" entryType="K" lang="EN" nocore="yes">
						<textBody>
							<title>
								<titlePart>
									<text>for charging batteries from dynamo-electric generators driven at varying speed, e.g. on vehicle</text>
								</titlePart>
							</title>
						</textBody>
						<ipcEntry kind="2" symbol="H02J0007160000" ipcLevel="C" entryType="K" lang="EN" nocore="yes">
							<textBody>
								<title>
									<titlePart>
										<text>Regulation of the charging current or voltage by variation of field</text>
									</titlePart>
								</title>
							</textBody>
							<ipcEntry kind="3" symbol="H02J0007180000" ipcLevel="A" entryType="K" lang="EN" nocore="yes">
								<textBody>
									<title>
										<titlePart>
											<text>due to variation of ohmic resistance in field circuit, using resistance switching in or out of circuit step by step</text>
										</titlePart>
									</title>
								</textBody>
							</ipcEntry>
							<ipcEntry kind="3" symbol="H02J0007200000" ipcLevel="A" entryType="K" lang="EN" nocore="yes">
								<textBody>
									<title>
										<titlePart>
											<text>due to variation of continuously-variable ohmic resistor</text>
										</titlePart>
									</title>
								</textBody>
							</ipcEntry>
							<ipcEntry kind="3" symbol="H02J0007220000" ipcLevel="A" entryType="K" lang="EN" nocore="yes">
								<textBody>
									<title>
										<titlePart>
											<text>due to variation of make-to-break ratio of intermittently-operating contacts, e.g. using Tirrill regulator</text>
										</titlePart>
									</title>
								</textBody>
							</ipcEntry>
							<ipcEntry kind="3" symbol="H02J0007240000" ipcLevel="A" entryType="K" lang="EN" nocore="yes">
								<textBody>
									<title>
										<titlePart>
											<text>using discharge tubes or semiconductor devices</text>
										</titlePart>
									</title>
								</textBody>
							</ipcEntry>
							<ipcEntry kind="3" symbol="H02J0007260000" ipcLevel="A" entryType="K" lang="EN" nocore="yes">
								<textBody>
									<title>
										<titlePart>
											<text>using magnetic devices with controllable degree of saturation</text>
										</titlePart>
									</title>
								</textBody>
							</ipcEntry>
							<ipcEntry kind="3" symbol="H02J0007280000" ipcLevel="A" entryType="K" lang="EN" nocore="yes">
								<textBody>
									<title>
										<titlePart>
											<text>using magnetic devices with controllable degree of saturation in combination with controlled discharge tube or controlled semiconductor device</text>
										</titlePart>
									</title>
								</textBody>
							</ipcEntry>
							<ipcEntry kind="3" symbol="H02J0007300000" ipcLevel="A" entryType="K" lang="EN" nocore="yes">
								<textBody>
									<title>
										<titlePart>
											<text>using armature-reaction-excited machines</text>
										</titlePart>
									</title>
								</textBody>
							</ipcEntry>
						</ipcEntry>
					</ipcEntry>
					<ipcEntry kind="1" symbol="H02J0007320000" ipcLevel="C" entryType="K" lang="EN" nocore="yes">
						<textBody>
							<title>
								<titlePart>
									<text>for charging batteries from a charging set comprising a non-electric prime mover</text>
								</titlePart>
							</title>
						</textBody>
					</ipcEntry>
					<ipcEntry kind="1" symbol="H02J0007340000" ipcLevel="C" edition="19850101" entryType="K" lang="EN" nocore="yes">
						<textBody>
							<title>
								<titlePart>
									<text>Parallel operation in networks using both storage and other dc sources, e.g. providing buffering</text>
									<entryReference><sref ref="H02J0007140000"/> takes precedence</entryReference>
								</titlePart>
							</title>
						</textBody>
						<ipcEntry kind="2" symbol="H02J0007350000" ipcLevel="C" edition="19850101" entryType="K" lang="EN" nocore="yes">
							<textBody>
								<title>
									<titlePart>
										<text>with light sensitive cells</text>
									</titlePart>
								</title>
							</textBody>
						</ipcEntry>
					</ipcEntry>
					<ipcEntry kind="1" symbol="H02J0007360000" ipcLevel="C" entryType="K" lang="EN" nocore="yes">
						<textBody>
							<title>
								<titlePart>
									<text>Arrangements using end-cell switching</text>
								</titlePart>
							</title>
						</textBody>
					</ipcEntry>
				</ipcEntry>
				<ipcEntry kind="m" symbol="H02J0009000000" ipcLevel="C" entryType="K" lang="EN" priorityOrder="70" nocore="yes">
					<textBody>
						<title>
							<titlePart>
								<text>Circuit arrangements for emergency or stand-by power supply, e.g. for emergency lighting</text>
								<entryReference>with provision for charging standby battery <sref ref="H02J0007000000"/></entryReference>
							</titlePart>
						</title>
					</textBody>
					<ipcEntry kind="1" symbol="H02J0009020000" ipcLevel="A" entryType="K" lang="EN" nocore="yes">
						<textBody>
							<title>
								<titlePart>
									<text>in which an auxiliary distribution system and its associated lamps are brought into service</text>
								</titlePart>
							</title>
						</textBody>
					</ipcEntry>
					<ipcEntry kind="1" symbol="H02J0009040000" ipcLevel="C" entryType="K" lang="EN" nocore="yes">
						<textBody>
							<title>
								<titlePart>
									<text>in which the distribution system is disconnected from the normal source and connected to a standby source</text>
								</titlePart>
							</title>
						</textBody>
						<ipcEntry kind="2" symbol="H02J0009060000" ipcLevel="C" entryType="K" lang="EN" nocore="yes">
							<textBody>
								<title>
									<titlePart>
										<text>with automatic change-over</text>
									</titlePart>
								</title>
							</textBody>
							<ipcEntry kind="3" symbol="H02J0009080000" ipcLevel="C" entryType="K" lang="EN" nocore="yes">
								<textBody>
									<title>
										<titlePart>
											<text>requiring starting of a prime-mover</text>
										</titlePart>
									</title>
								</textBody>
							</ipcEntry>
						</ipcEntry>
					</ipcEntry>
				</ipcEntry>
				<ipcEntry kind="m" symbol="H02J0011000000" ipcLevel="C" entryType="K" lang="EN" priorityOrder="80" nocore="yes">
					<textBody>
						<title>
							<titlePart>
								<text>Circuit arrangements for providing service supply to auxiliaries of stations in which electric power is generated, distributed, or converted</text>
								<entryReference>emergency or standby arrangements <sref ref="H02J0009000000"/></entryReference>
							</titlePart>
						</title>
					</textBody>
				</ipcEntry>
				<ipcEntry kind="m" symbol="H02J0013000000" ipcLevel="C" entryType="K" lang="EN" priorityOrder="0" nocore="yes">
					<textBody>
						<title>
							<titlePart>
								<text>Circuit arrangements for providing remote indication of network conditions, e.g. an instantaneous record of the open or closed condition of each circuitbreaker in the network</text>
							</titlePart>
							<titlePart>
								<text>Circuit arrangements for providing remote control of switching means in a power distribution network, e.g. switching in and out of current consumers by using a pulse code signal carried by the network</text>
							</titlePart>
						</title>
					</textBody>
				</ipcEntry>
				<ipcEntry kind="m" symbol="H02J0015000000" ipcLevel="C" edition="19740701" entryType="K" lang="EN" priorityOrder="90" nocore="yes">
					<textBody>
						<title>
							<titlePart>
								<text>Systems for storing electric energy</text>
								<entryReference>mechanical systems therefor <mref ref="F01" endRef="F04"/></entryReference>
								<entryReference>in chemical form <sref ref="H01M"/></entryReference>
							</titlePart>
						</title>
					</textBody>
				</ipcEntry>
				<ipcEntry kind="m" symbol="H02J0017000000" ipcLevel="C" edition="19800101" entryType="K" lang="EN" priorityOrder="10" nocore="yes">
					<textBody>
						<title>
							<titlePart>
								<text>Systems for supplying or distributing electric power by electromagnetic waves</text>
							</titlePart>
						</title>
					</textBody>
				</ipcEntry>
			</ipcEntry>
		</ipcEntry>
	</ipcEntry>
</ipcEntries>
