<?xml version="1.0" encoding="utf-8"?>
<?xml-stylesheet href="ipcentry.xsl" type="text/xsl"?>
<ipcEntries displayMode="e20080401;a20080401;c20060101" ipcLevel="a" split="subclass" languages=",en,fr," size="97280">
	<ipcEntry kind="s" symbol="G" ipcLevel="C" entryType="K" lang="EN" nocore="yes">
		<textBody>
			<title>
				<titlePart>
					<text>SECTION G <emdash/> PHYSICS</text>
				</titlePart>
			</title>
		</textBody>
		<ipcEntry kind="n" symbol="G" ipcLevel="C" entryType="K" lang="EN" nocore="yes">
			<textBody>
				<note type="number">
					<noteParagraph>
						<text>In this section, the following term is used with the meaning indicated:</text>
						<subnote type="bullet">
							<noteParagraph>
								<text>"variable" (as a noun) means a feature or property (e.g., a dimension, a physical condition such as temperature, a quality such as density or colour) which, in respect of a particular entity (e.g., an object, a quantity of a substance, a beam of light) and at a particular instant, is capable of being measured; the variable may change, so that its numerical expression may assume different values at different times, in different conditions or in individual cases, but may be constant in respect of a particular entity in certain conditions or for practical purposes (e.g., the length of a bar may be regarded as constant for many purposes).</text>
							</noteParagraph>
						</subnote>
					</noteParagraph>
					<noteParagraph>
						<text>Attention is drawn to the definitions of terms or expressions used, appearing in the notes of several of the classes in this section, in particular those of "measuring" in class <sref ref="G01"/> and "control" and "regulation" in class <sref ref="G05"/>.</text>
					</noteParagraph>
					<noteParagraph>
						<text>Classification in this section may present more difficulty than in other sections, because the distinction between different fields of use rests to a considerable extent on differences in the intention of the user rather than on any constructional differences or differences in the manner of use, and because the subjects dealt with are often in effect systems or combinations, which have features or parts in common, rather than "things", which are readily distinguishable as a whole. For example, information (e.g., a set of figures) may be displayed for the purpose of education or advertising (<sref ref="G09"/>), for enabling the result of a measurement to be known (<sref ref="G01"/>), for signalling the information to a distant point or for giving information which has been signalled from a distant point (<sref ref="G08"/>). The words used to describe the purpose depend on features that may be irrelevant to the form of the apparatus concerned, for example, such features as the desired effect on the person who sees the display, or whether the display is controlled from a remote point. Again, a device which responds to some change in a condition, e.g., in the pressure of a fluid, may be used, without modification of the device itself, to give information about the pressure (<sref ref="G01L"/>) or about some other condition linked to the pressure (another subclass of class <sref ref="G01"/>, e.g., <sref ref="G01K"/> for temperature), to make a record of the pressure or of its occurrence (<sref ref="G07C"/>), to give an alarm (<sref ref="G08B"/>), or to control another apparatus (<sref ref="G05"/>).</text>
						<subnote type="none">
							<noteParagraph>
								<text>The classification scheme is intended to enable things of a similar nature (as indicated above) to be classified together. It is therefore particularly necessary for the real nature of any technical subject to be decided before it can be properly classified.</text>
							</noteParagraph>
						</subnote>
					</noteParagraph>
				</note>
			</textBody>
		</ipcEntry>
		<ipcEntry kind="t" symbol="G01" ipcLevel="C" entryType="K" lang="EN" nocore="yes">
			<textBody>
				<title>
					<titlePart>
						<text>INSTRUMENTS</text>
					</titlePart>
				</title>
			</textBody>
		</ipcEntry>
		<ipcEntry kind="c" symbol="G01" ipcLevel="C" entryType="K" lang="EN" nocore="yes">
			<textBody>
				<title>
					<titlePart>
						<text>MEASURING</text>
						<entryReference>counting <sref ref="G06M"/></entryReference>
					</titlePart>
					<titlePart>
						<text>TESTING</text>
					</titlePart>
				</title>
			</textBody>
			<ipcEntry kind="n" symbol="G01" ipcLevel="C" entryType="K" lang="EN" nocore="yes">
				<textBody>
					<note type="number">
						<noteParagraph>
							<text>This class <u>covers</u>, in addition to "true" measuring instruments, other indicating or recording devices of analogous construction, and also signalling or control devices insofar as they are concerned with measurement (as defined in Note 2 below) and are not specially adapted to the particular purpose of signalling or control.</text>
						</noteParagraph>
						<noteParagraph>
							<text>In this class, the following term is used with the meaning indicated:</text>
							<subnote type="bullet">
								<noteParagraph>
									<text>"measuring" is used to cover considerably more than its primary or basic meaning. In this primary sense, it means finding a numerical expression of the value of a variable in relation to a unit or datum or to another variable of the same nature, e.g. expressing a length in terms of another length as in measuring a length with a scale; the value may be obtained directly (as just suggested) or by measuring some other variable of which the value can be related to the value of the required variable, as in measuring a change in temperature by measuring a resultant change in the length of a column of mercury. However, since the same device or instrument may, instead of giving an immediate indication, be used to produce a record or to initiate a signal to produce an indication or control effect, or may be used in combination with other devices or instruments to give a conjoint result from measurement of two or more variables of the same or different kinds, it is necessary to interpret "measuring" as including also any operation that would make it possible to obtain such a numerical expression by the additional use of some way of converting a value into figures. Thus the expression in figures may be actually made by a digital presentation or by reading a scale, or an indication of it may be given without the use of figures, e.g. by some perceptible feature (variable) of the entity (e.g. object, substance, beam of light) of which the variable being measured is a property or condition or by an analogue of such a feature (e.g. the corresponding position of a member without any scale, a corresponding voltage generated in some way). In many cases there is no such value indication but only an indication of difference or equality in relation to a standard or datum (of which the value may or may not be known in figures); the standard or datum may be the value of another variable of the same nature but of a different entity (e.g. a standard measure) or of the same entity at a different time.</text>
									<subnote type="none">
										<noteParagraph>
											<text>In its simplest form, measurement may give merely an indication of presence or absence of a certain condition or quality, e.g. movement (in any direction or in a particular direction), or whether a variable exceeds a predetermined value.</text>
										</noteParagraph>
									</subnote>
								</noteParagraph>
							</subnote>
						</noteParagraph>
						<noteParagraph edition="20000101">
							<text>Attention is drawn to the Notes following the titles of class <sref ref="B81"/> and subclass <sref ref="B81B"/> relating to "micro-structural devices" and "micro-structural systems" and the Notes following the title of subclass <sref ref="B82B"/> relating to "nano-structures".</text>
						</noteParagraph>
						<noteParagraph>
							<text>Attention is drawn to the Notes following the title of section G, especially as regards the definition of the term "variable".</text>
						</noteParagraph>
						<noteParagraph edition="19950101">
							<text>In many measuring arrangements, a first variable to be measured is transformed into a second, or further, variables. The second, or further, variables may be (a) a condition related to the first variable and produced in a member, or (b) a displacement of a member. Further transformation may be needed.<nbsp/></text>
							<subnote type="none">
								<noteParagraph edition="19950101">
									<text>When classifying such an arrangement, (i) the transformation step, or each transformation step, that is of interest is classified, or (ii) if interest lies only in the system as a whole, the first variable is classified in the appropriate place.<nbsp/></text>
								</noteParagraph>
								<noteParagraph edition="19950101">
									<text>This is particularly important where two or more conversions take place, for instance where a first variable, for example pressure, is transformed into a second variable, for example an optical property of a sensing body, and that second variable is expressed by means of a third variable, for example an electric effect. In such a case, the following classification places should be considered: the place for the transformation of the first variable, that for sensing the condition caused by that variable, subclass <sref ref="G01D"/> for expression of the measurement, and finally the place for the overall system, if any.<nbsp/></text>
								</noteParagraph>
							</subnote>
						</noteParagraph>
						<noteParagraph>
							<text>The measurement of change in the value of a physical property is classified in the same subclass as the measurement of that physical property, e.g. measurement of expansion of length is classified in subclass <sref ref="G01B"/>.</text>
						</noteParagraph>
					</note>
				</textBody>
			</ipcEntry>
			<ipcEntry kind="u" symbol="G01K" ipcLevel="C" entryType="K" lang="EN" nocore="yes">
				<textBody>
					<title>
						<titlePart>
							<text>MEASURING TEMPERATURE</text>
						</titlePart>
						<titlePart>
							<text>MEASURING QUANTITY OF HEAT</text>
						</titlePart>
						<titlePart>
							<text>THERMALLY-SENSITIVE ELEMENTS NOT OTHERWISE PROVIDED FOR</text>
							<entryReference>sensing temperature changes for compensating measurements of other variables or for compensating readings of instruments for variations in temperature, <u>see</u><sref ref="G01D"/> or relevant subclass for variable measured</entryReference>
							<entryReference>radiation pyrometry <sref ref="G01J"/></entryReference>
							<entryReference>investigating or analysing materials by use of thermal means <sref ref="G01N0025000000"/></entryReference>
							<entryReference>compound sensitive elements, e.g. bimetallic, <sref ref="G12B0001020000"/></entryReference>
						</titlePart>
					</title>
				</textBody>
				<ipcEntry kind="n" symbol="G01K" ipcLevel="C" entryType="K" lang="EN" nocore="yes">
					<textBody>
						<note type="number">
							<noteParagraph>
								<text>In this subclass, the following term is used with the meaning indicated:</text>
								<subnote type="bullet">
									<noteParagraph>
										<text>"thermometer" includes thermally-sensitive elements not provided for in other subclasses.</text>
									</noteParagraph>
								</subnote>
							</noteParagraph>
							<noteParagraph>
								<text>Attention is drawn to the Notes following the title of class <sref ref="G01"/>.</text>
							</noteParagraph>
						</note>
					</textBody>
				</ipcEntry>
				<ipcEntry kind="i" symbol="G01K" ipcLevel="C" entryType="K" lang="EN" nocore="yes">
					<textBody>
						<index>
							<indexEntry>
								<text>MEASURING TEMPERATURE</text>
								<indexEntry>
									<text>characterised by principle of operation </text>
									<references><sref ref="G01K0005000000"/>, <sref ref="G01K0007000000"/>, <sref ref="G01K0009000000"/>, <sref ref="G01K0011000000"/></references>
								</indexEntry>
								<indexEntry>
									<text>Thermometers giving an indication other than the instantaneous value </text>
									<references><sref ref="G01K0003000000"/></references>
								</indexEntry>
								<indexEntry>
									<text>Details of thermometers not specially adapted for particular types of thermometers </text>
									<references><sref ref="G01K0001000000"/></references>
								</indexEntry>
								<indexEntry>
									<text>Adaptations of thermometers for specific purposes </text>
									<references><sref ref="G01K0013000000"/></references>
								</indexEntry>
								<indexEntry>
									<text>Testing and calibrating of thermometers </text>
									<references><sref ref="G01K0015000000"/></references>
								</indexEntry>
							</indexEntry>
							<indexEntry>
								<text>MEASURING QUANTITY OF HEAT; TESTING AND CALIBRATING OF CALORIMETERS </text>
								<references><sref ref="G01K0017000000"/>; <sref ref="G01K0019000000"/></references>
							</indexEntry>
						</index>
					</textBody>
				</ipcEntry>
				<ipcEntry kind="m" symbol="G01K0001000000" ipcLevel="C" edition="19950101" entryType="K" lang="EN" priorityOrder="90" nocore="yes">
					<textBody>
						<title>
							<titlePart>
								<text>Details of thermometers not specially adapted for particular types of thermometer</text>
								<entryReference>circuits for reducing thermal inertia <sref ref="G01K0007420000"/></entryReference>
							</titlePart>
						</title>
					</textBody>
					<ipcEntry kind="1" symbol="G01K0001020000" ipcLevel="A" entryType="K" lang="EN" nocore="yes">
						<textBody>
							<title>
								<titlePart>
									<text>Special applications of indicating or recording means, e.g. for remote indications</text>
								</titlePart>
							</title>
						</textBody>
						<ipcEntry kind="2" symbol="G01K0001040000" ipcLevel="A" entryType="K" lang="EN" nocore="yes">
							<textBody>
								<title>
									<titlePart>
										<text>Scales</text>
									</titlePart>
								</title>
							</textBody>
							<ipcEntry kind="3" symbol="G01K0001060000" ipcLevel="A" entryType="K" lang="EN" nocore="yes">
								<textBody>
									<title>
										<titlePart>
											<text>Arrangements for facilitating reading, e.g. illumination, magnifying glass</text>
										</titlePart>
									</title>
								</textBody>
							</ipcEntry>
						</ipcEntry>
					</ipcEntry>
					<ipcEntry kind="1" symbol="G01K0001080000" ipcLevel="C" entryType="K" lang="EN" nocore="yes">
						<textBody>
							<title>
								<titlePart>
									<text>Protective devices, e.g. casings</text>
								</titlePart>
							</title>
						</textBody>
						<ipcEntry kind="2" symbol="G01K0001100000" ipcLevel="A" entryType="K" lang="EN" nocore="yes">
							<textBody>
								<title>
									<titlePart>
										<text>for preventing chemical attack</text>
									</titlePart>
								</title>
							</textBody>
						</ipcEntry>
						<ipcEntry kind="2" symbol="G01K0001120000" ipcLevel="A" entryType="K" lang="EN" nocore="yes">
							<textBody>
								<title>
									<titlePart>
										<text>for preventing damage due to heat overloading</text>
									</titlePart>
								</title>
							</textBody>
						</ipcEntry>
					</ipcEntry>
					<ipcEntry kind="1" symbol="G01K0001140000" ipcLevel="C" entryType="K" lang="EN" nocore="yes">
						<textBody>
							<title>
								<titlePart>
									<text>Supports</text>
								</titlePart>
								<titlePart>
									<text>Fastening devices</text>
								</titlePart>
								<titlePart>
									<text>Mounting thermometers in particular locations</text>
								</titlePart>
							</title>
						</textBody>
					</ipcEntry>
					<ipcEntry kind="1" symbol="G01K0001160000" ipcLevel="A" entryType="K" lang="EN" nocore="yes">
						<textBody>
							<title>
								<titlePart>
									<text>Special arrangements for conducting heat from the object to the sensitive element</text>
								</titlePart>
							</title>
						</textBody>
						<ipcEntry kind="2" symbol="G01K0001180000" ipcLevel="A" entryType="K" lang="EN" nocore="yes">
							<textBody>
								<title>
									<titlePart>
										<text>for reducing thermal inertia</text>
									</titlePart>
								</title>
							</textBody>
						</ipcEntry>
					</ipcEntry>
					<ipcEntry kind="1" symbol="G01K0001200000" ipcLevel="A" entryType="K" lang="EN" nocore="yes">
						<textBody>
							<title>
								<titlePart>
									<text>Compensating for effects of temperature changes other than those to be measured, e.g. changes in ambient temperature</text>
								</titlePart>
							</title>
						</textBody>
						<ipcEntry kind="2" symbol="G01K0001220000" ipcLevel="A" entryType="K" lang="EN" nocore="yes">
							<textBody>
								<title>
									<titlePart>
										<text>by means of fluid contained in a hollow body having parts which are deformable or displaceable under the pressure developed by the fluid</text>
									</titlePart>
								</title>
							</textBody>
						</ipcEntry>
						<ipcEntry kind="2" symbol="G01K0001240000" ipcLevel="A" entryType="K" lang="EN" nocore="yes">
							<textBody>
								<title>
									<titlePart>
										<text>by means of compounded strips or plates, e.g. bimetallic strips</text>
									</titlePart>
								</title>
							</textBody>
						</ipcEntry>
					</ipcEntry>
					<ipcEntry kind="1" symbol="G01K0001260000" ipcLevel="A" entryType="K" lang="EN" nocore="yes">
						<textBody>
							<title>
								<titlePart>
									<text>Compensating for effects of pressure changes</text>
								</titlePart>
							</title>
						</textBody>
					</ipcEntry>
				</ipcEntry>
				<ipcEntry kind="m" symbol="G01K0003000000" ipcLevel="C" edition="19950101" entryType="K" lang="EN" priorityOrder="30" nocore="yes">
					<textBody>
						<title>
							<titlePart>
								<text>Thermometers giving results other than momentary value of temperature</text>
								<entryReference><sref ref="G01K0007420000"/> takes precedence</entryReference>
								<entryReference>using thermo-electric elements <sref ref="G01K0007020000"/></entryReference>
							</titlePart>
						</title>
					</textBody>
					<ipcEntry kind="1" symbol="G01K0003020000" ipcLevel="A" entryType="K" lang="EN" nocore="yes">
						<textBody>
							<title>
								<titlePart>
									<text>giving mean values</text>
								</titlePart>
								<titlePart>
									<text>giving integrated values</text>
								</titlePart>
							</title>
						</textBody>
						<ipcEntry kind="2" symbol="G01K0003040000" ipcLevel="A" entryType="K" lang="EN" nocore="yes">
							<textBody>
								<title>
									<titlePart>
										<text>in respect of time</text>
									</titlePart>
								</title>
							</textBody>
						</ipcEntry>
						<ipcEntry kind="2" symbol="G01K0003060000" ipcLevel="A" entryType="K" lang="EN" nocore="yes">
							<textBody>
								<title>
									<titlePart>
										<text>in respect of space</text>
									</titlePart>
								</title>
							</textBody>
						</ipcEntry>
					</ipcEntry>
					<ipcEntry kind="1" symbol="G01K0003080000" ipcLevel="A" entryType="K" lang="EN" nocore="yes">
						<textBody>
							<title>
								<titlePart>
									<text>giving differences of values</text>
								</titlePart>
								<titlePart>
									<text>giving differentiated values</text>
								</titlePart>
							</title>
						</textBody>
						<ipcEntry kind="2" symbol="G01K0003100000" ipcLevel="A" entryType="K" lang="EN" nocore="yes">
							<textBody>
								<title>
									<titlePart>
										<text>in respect of time, e.g. reacting only to a quick change of temperature</text>
									</titlePart>
								</title>
							</textBody>
							<ipcEntry kind="3" symbol="G01K0003120000" ipcLevel="A" entryType="K" lang="EN" nocore="yes">
								<textBody>
									<title>
										<titlePart>
											<text>based upon expansion or contraction of materials</text>
										</titlePart>
									</title>
								</textBody>
							</ipcEntry>
						</ipcEntry>
						<ipcEntry kind="2" symbol="G01K0003140000" ipcLevel="A" entryType="K" lang="EN" nocore="yes">
							<textBody>
								<title>
									<titlePart>
										<text>in respect of space</text>
									</titlePart>
								</title>
							</textBody>
						</ipcEntry>
					</ipcEntry>
				</ipcEntry>
				<ipcEntry kind="m" symbol="G01K0005000000" ipcLevel="C" entryType="K" lang="EN" priorityOrder="70" nocore="yes">
					<textBody>
						<title>
							<titlePart>
								<text>Measuring temperature based on the expansion or contraction of a material</text>
								<entryReference><sref ref="G01K0009000000"/> takes precedence</entryReference>
								<entryReference>giving other than momentary value of temperature <sref ref="G01K0003000000"/></entryReference>
								<entryReference>of vapour arising from a liquid <sref ref="G01K0011020000"/></entryReference>
								<entryReference>thermally-actuated switches <sref ref="H01H"/></entryReference>
							</titlePart>
						</title>
					</textBody>
					<ipcEntry kind="1" symbol="G01K0005020000" ipcLevel="A" entryType="K" lang="EN" nocore="yes">
						<textBody>
							<title>
								<titlePart>
									<text>the material being a liquid</text>
									<entryReference>contained in a hollow body having parts which are deformable or displaceable under the pressure developed by the material <sref ref="G01K0005320000"/></entryReference>
								</titlePart>
							</title>
						</textBody>
						<ipcEntry kind="2" symbol="G01K0005040000" ipcLevel="A" entryType="K" lang="EN" nocore="yes">
							<textBody>
								<title>
									<titlePart>
										<text>Details</text>
									</titlePart>
								</title>
							</textBody>
							<ipcEntry kind="3" symbol="G01K0005060000" ipcLevel="A" entryType="K" lang="EN" nocore="yes">
								<textBody>
									<title>
										<titlePart>
											<text>Arrangements for driving back the liquid column</text>
										</titlePart>
									</title>
								</textBody>
							</ipcEntry>
							<ipcEntry kind="3" symbol="G01K0005080000" ipcLevel="A" entryType="K" lang="EN" nocore="yes">
								<textBody>
									<title>
										<titlePart>
											<text>Capillary tubes</text>
										</titlePart>
									</title>
								</textBody>
							</ipcEntry>
							<ipcEntry kind="3" symbol="G01K0005100000" ipcLevel="A" entryType="K" lang="EN" nocore="yes">
								<textBody>
									<title>
										<titlePart>
											<text>Containers for the liquid</text>
										</titlePart>
									</title>
								</textBody>
							</ipcEntry>
							<ipcEntry kind="3" symbol="G01K0005120000" ipcLevel="A" entryType="K" lang="EN" nocore="yes">
								<textBody>
									<title>
										<titlePart>
											<text>Selection of liquid compositions</text>
										</titlePart>
									</title>
								</textBody>
							</ipcEntry>
						</ipcEntry>
						<ipcEntry kind="2" symbol="G01K0005140000" ipcLevel="A" entryType="K" lang="EN" nocore="yes">
							<textBody>
								<title>
									<titlePart>
										<text>the liquid displacing a further liquid column or a solid body</text>
										<entryReference>for maximum or minimum indication <sref ref="G01K0005200000"/></entryReference>
									</titlePart>
								</title>
							</textBody>
						</ipcEntry>
						<ipcEntry kind="2" symbol="G01K0005160000" ipcLevel="A" entryType="K" lang="EN" nocore="yes">
							<textBody>
								<title>
									<titlePart>
										<text>with electric contacts</text>
									</titlePart>
								</title>
							</textBody>
						</ipcEntry>
						<ipcEntry kind="2" symbol="G01K0005180000" ipcLevel="A" entryType="K" lang="EN" nocore="yes">
							<textBody>
								<title>
									<titlePart>
										<text>with electric conversion means for final indication</text>
									</titlePart>
								</title>
							</textBody>
						</ipcEntry>
						<ipcEntry kind="2" symbol="G01K0005200000" ipcLevel="A" entryType="K" lang="EN" nocore="yes">
							<textBody>
								<title>
									<titlePart>
										<text>with means for indicating a maximum or a minimum or both</text>
										<entryReference><sref ref="G01K0005220000"/> takes precedence</entryReference>
									</titlePart>
								</title>
							</textBody>
						</ipcEntry>
						<ipcEntry kind="2" symbol="G01K0005220000" ipcLevel="A" entryType="K" lang="EN" nocore="yes">
							<textBody>
								<title>
									<titlePart>
										<text>with provision for expansion indicating over not more than a few degrees, e.g. clinical thermometer</text>
									</titlePart>
								</title>
							</textBody>
						</ipcEntry>
						<ipcEntry kind="2" symbol="G01K0005240000" ipcLevel="A" entryType="K" lang="EN" nocore="yes">
							<textBody>
								<title>
									<titlePart>
										<text>with provision for measuring the difference between two temperatures</text>
									</titlePart>
								</title>
							</textBody>
						</ipcEntry>
						<ipcEntry kind="2" symbol="G01K0005260000" ipcLevel="A" entryType="K" lang="EN" nocore="yes">
							<textBody>
								<title>
									<titlePart>
										<text>with provision for adjusting zero point of scale, e.g. Beckmann thermometer</text>
									</titlePart>
								</title>
							</textBody>
						</ipcEntry>
					</ipcEntry>
					<ipcEntry kind="1" symbol="G01K0005280000" ipcLevel="A" entryType="K" lang="EN" nocore="yes">
						<textBody>
							<title>
								<titlePart>
									<text>the material being a gas</text>
									<entryReference>contained in a hollow body having parts which are deformable or displaceable under the pressure developed by the material <sref ref="G01K0005320000"/></entryReference>
								</titlePart>
							</title>
						</textBody>
						<ipcEntry kind="2" symbol="G01K0005300000" ipcLevel="A" entryType="K" lang="EN" nocore="yes">
							<textBody>
								<title>
									<titlePart>
										<text>the gas displacing a liquid column</text>
									</titlePart>
								</title>
							</textBody>
						</ipcEntry>
					</ipcEntry>
					<ipcEntry kind="1" symbol="G01K0005320000" ipcLevel="A" entryType="K" lang="EN" nocore="yes">
						<textBody>
							<title>
								<titlePart>
									<text>the material being a fluid contained in a hollow body having parts which are deformable or displaceable under the pressure developed by the material</text>
									<entryReference>under pressure developed by evaporation <sref ref="G01K0011040000"/></entryReference>
									<entryReference>pressure-measuring devices in general <sref ref="G01L"/></entryReference>
								</titlePart>
							</title>
						</textBody>
						<ipcEntry kind="2" symbol="G01K0005340000" ipcLevel="A" entryType="K" lang="EN" nocore="yes">
							<textBody>
								<title>
									<titlePart>
										<text>the body being a capsule</text>
										<entryReference><sref ref="G01K0005360000"/>, <sref ref="G01K0005420000"/> take precedence</entryReference>
									</titlePart>
								</title>
							</textBody>
						</ipcEntry>
						<ipcEntry kind="2" symbol="G01K0005360000" ipcLevel="A" entryType="K" lang="EN" nocore="yes">
							<textBody>
								<title>
									<titlePart>
										<text>the body being a tubular spring, e.g. Bourdon tube</text>
									</titlePart>
								</title>
							</textBody>
							<ipcEntry kind="3" symbol="G01K0005380000" ipcLevel="A" entryType="K" lang="EN" nocore="yes">
								<textBody>
									<title>
										<titlePart>
											<text>of spiral formation</text>
										</titlePart>
									</title>
								</textBody>
							</ipcEntry>
							<ipcEntry kind="3" symbol="G01K0005400000" ipcLevel="A" entryType="K" lang="EN" nocore="yes">
								<textBody>
									<title>
										<titlePart>
											<text>of helical formation</text>
										</titlePart>
									</title>
								</textBody>
							</ipcEntry>
						</ipcEntry>
						<ipcEntry kind="2" symbol="G01K0005420000" ipcLevel="A" entryType="K" lang="EN" nocore="yes">
							<textBody>
								<title>
									<titlePart>
										<text>the body being a bellows</text>
									</titlePart>
								</title>
							</textBody>
						</ipcEntry>
						<ipcEntry kind="2" symbol="G01K0005440000" ipcLevel="A" entryType="K" lang="EN" nocore="yes">
							<textBody>
								<title>
									<titlePart>
										<text>the body being a cylinder and piston</text>
									</titlePart>
								</title>
							</textBody>
						</ipcEntry>
						<ipcEntry kind="2" symbol="G01K0005460000" ipcLevel="A" entryType="K" lang="EN" nocore="yes">
							<textBody>
								<title>
									<titlePart>
										<text>with electric conversion means for final indication</text>
									</titlePart>
								</title>
							</textBody>
						</ipcEntry>
					</ipcEntry>
					<ipcEntry kind="1" symbol="G01K0005480000" ipcLevel="A" entryType="K" lang="EN" nocore="yes">
						<textBody>
							<title>
								<titlePart>
									<text>the material being a solid</text>
								</titlePart>
							</title>
						</textBody>
						<ipcEntry kind="2" symbol="G01K0005500000" ipcLevel="A" entryType="K" lang="EN" nocore="yes">
							<textBody>
								<title>
									<titlePart>
										<text>arranged for free expansion or contraction</text>
									</titlePart>
								</title>
							</textBody>
							<ipcEntry kind="3" symbol="G01K0005520000" ipcLevel="A" entryType="K" lang="EN" nocore="yes">
								<textBody>
									<title>
										<titlePart>
											<text>with electrical conversion means for final indication</text>
										</titlePart>
									</title>
								</textBody>
							</ipcEntry>
						</ipcEntry>
						<ipcEntry kind="2" symbol="G01K0005540000" ipcLevel="A" entryType="K" lang="EN" nocore="yes">
							<textBody>
								<title>
									<titlePart>
										<text>consisting of pivotally-connected elements</text>
									</titlePart>
								</title>
							</textBody>
						</ipcEntry>
						<ipcEntry kind="2" symbol="G01K0005560000" ipcLevel="A" entryType="K" lang="EN" nocore="yes">
							<textBody>
								<title>
									<titlePart>
										<text>constrained so that expansion or contraction causes a deformation of the solid</text>
									</titlePart>
								</title>
							</textBody>
							<ipcEntry kind="3" symbol="G01K0005580000" ipcLevel="A" entryType="K" lang="EN" nocore="yes">
								<textBody>
									<title>
										<titlePart>
											<text>the solid body being constrained at more than one point, e.g. rod, plate, diaphragm</text>
											<entryReference><sref ref="G01K0005620000"/> takes precedence</entryReference>
										</titlePart>
									</title>
								</textBody>
								<ipcEntry kind="4" symbol="G01K0005600000" ipcLevel="A" entryType="K" lang="EN" nocore="yes">
									<textBody>
										<title>
											<titlePart>
												<text>the body being a flexible wire or ribbon</text>
											</titlePart>
										</title>
									</textBody>
								</ipcEntry>
							</ipcEntry>
							<ipcEntry kind="3" symbol="G01K0005620000" ipcLevel="A" entryType="K" lang="EN" nocore="yes">
								<textBody>
									<title>
										<titlePart>
											<text>the solid body being formed of compounded strips or plates, e.g. bimetallic strip</text>
										</titlePart>
									</title>
								</textBody>
								<ipcEntry kind="4" symbol="G01K0005640000" ipcLevel="A" entryType="K" lang="EN" nocore="yes">
									<textBody>
										<title>
											<titlePart>
												<text>Details of the compound system</text>
											</titlePart>
										</title>
									</textBody>
									<ipcEntry kind="5" symbol="G01K0005660000" ipcLevel="A" entryType="K" lang="EN" nocore="yes">
										<textBody>
											<title>
												<titlePart>
													<text>Selection of composition of the components of the system</text>
												</titlePart>
											</title>
										</textBody>
									</ipcEntry>
									<ipcEntry kind="5" symbol="G01K0005680000" ipcLevel="A" entryType="K" lang="EN" nocore="yes">
										<textBody>
											<title>
												<titlePart>
													<text>Shape of the system</text>
												</titlePart>
											</title>
										</textBody>
									</ipcEntry>
								</ipcEntry>
								<ipcEntry kind="4" symbol="G01K0005700000" ipcLevel="A" entryType="K" lang="EN" nocore="yes">
									<textBody>
										<title>
											<titlePart>
												<text>specially adapted for indicating or recording</text>
											</titlePart>
										</title>
									</textBody>
									<ipcEntry kind="5" symbol="G01K0005720000" ipcLevel="A" entryType="K" lang="EN" nocore="yes">
										<textBody>
											<title>
												<titlePart>
													<text>with electric transmission means for final indication</text>
												</titlePart>
											</title>
										</textBody>
									</ipcEntry>
								</ipcEntry>
							</ipcEntry>
						</ipcEntry>
					</ipcEntry>
				</ipcEntry>
				<ipcEntry kind="m" symbol="G01K0007000000" ipcLevel="C" entryType="K" lang="EN" priorityOrder="50" nocore="yes">
					<textBody>
						<title>
							<titlePart>
								<text>Measuring temperature based on the use of electric or magnetic elements directly sensitive to heat</text>
								<entryReference>giving results other than momentary value of temperature <sref ref="G01K0003000000"/></entryReference>
								<entryReference>measuring electric or magnetic variables <sref ref="G01R"/></entryReference>
							</titlePart>
						</title>
					</textBody>
					<ipcEntry kind="1" symbol="G01K0007010000" ipcLevel="C" edition="19950101" entryType="K" lang="EN" nocore="yes">
						<textBody>
							<title>
								<titlePart>
									<text>using semiconducting elements having PN junctions</text>
									<entryReference><sref ref="G01K0007020000"/>, <sref ref="G01K0007160000"/>, <sref ref="G01K0007300000"/> take precedence</entryReference>
								</titlePart>
							</title>
						</textBody>
					</ipcEntry>
					<ipcEntry kind="1" symbol="G01K0007020000" ipcLevel="C" entryType="K" lang="EN" nocore="yes">
						<textBody>
							<title>
								<titlePart>
									<text>using thermo-electric elements, e.g. thermo-couples</text>
									<entryReference>thermo-electric or thermo-magnetic devices <u>per se</u><sref ref="H01L0035000000"/>, <sref ref="H01L0037000000"/></entryReference>
								</titlePart>
							</title>
						</textBody>
						<ipcEntry kind="2" symbol="G01K0007040000" ipcLevel="A" entryType="K" lang="EN" nocore="yes">
							<textBody>
								<title>
									<titlePart>
										<text>the object to be measured not forming one of the thermo-electric materials</text>
									</titlePart>
								</title>
							</textBody>
							<ipcEntry kind="3" symbol="G01K0007060000" ipcLevel="A" entryType="K" lang="EN" nocore="yes">
								<textBody>
									<title>
										<titlePart>
											<text>the thermo-electric materials being arranged one within the other with the junction at one end exposed to the object, e.g. sheathed type</text>
										</titlePart>
									</title>
								</textBody>
							</ipcEntry>
						</ipcEntry>
						<ipcEntry kind="2" symbol="G01K0007080000" ipcLevel="A" entryType="K" lang="EN" nocore="yes">
							<textBody>
								<title>
									<titlePart>
										<text>the object to be measured forming one of the thermo-electric materials, e.g. pointed type</text>
									</titlePart>
								</title>
							</textBody>
						</ipcEntry>
						<ipcEntry kind="2" symbol="G01K0007100000" ipcLevel="A" entryType="K" lang="EN" nocore="yes">
							<textBody>
								<title>
									<titlePart>
										<text>Arrangements for compensating for auxiliary variables, e.g. length of lead</text>
									</titlePart>
								</title>
							</textBody>
							<ipcEntry kind="3" symbol="G01K0007120000" ipcLevel="A" entryType="K" lang="EN" nocore="yes">
								<textBody>
									<title>
										<titlePart>
											<text>Arrangements with respect to the cold junction, e.g. preventing influence of temperature of surrounding air</text>
										</titlePart>
									</title>
								</textBody>
								<ipcEntry kind="4" symbol="G01K0007130000" ipcLevel="A" edition="19950101" entryType="K" lang="EN" nocore="yes">
									<textBody>
										<title>
											<titlePart>
												<text>Circuits for cold-junction compensation</text>
											</titlePart>
										</title>
									</textBody>
								</ipcEntry>
							</ipcEntry>
						</ipcEntry>
						<ipcEntry kind="2" symbol="G01K0007140000" ipcLevel="A" entryType="K" lang="EN" nocore="yes">
							<textBody>
								<title>
									<titlePart>
										<text>Arrangements for modifying the output characteristic, e.g. linearising</text>
									</titlePart>
								</title>
							</textBody>
						</ipcEntry>
					</ipcEntry>
					<ipcEntry kind="1" symbol="G01K0007160000" ipcLevel="C" entryType="K" lang="EN" nocore="yes">
						<textBody>
							<title>
								<titlePart>
									<text>using resistive elements</text>
									<entryReference>resistive elements <u>per se</u><sref ref="H01C"/>, <sref ref="H01L"/></entryReference>
								</titlePart>
							</title>
						</textBody>
						<ipcEntry kind="2" symbol="G01K0007180000" ipcLevel="A" entryType="K" lang="EN" nocore="yes">
							<textBody>
								<title>
									<titlePart>
										<text>the element being a linear resistance, e.g. platinum resistance thermometer</text>
										<entryReference><sref ref="G01K0007260000"/> takes precedence</entryReference>
									</titlePart>
								</title>
							</textBody>
							<ipcEntry kind="3" symbol="G01K0007200000" ipcLevel="A" entryType="K" lang="EN" nocore="yes">
								<textBody>
									<title>
										<titlePart>
											<text>in a specially-adapted circuit, e.g. bridge circuit</text>
										</titlePart>
									</title>
								</textBody>
								<ipcEntry kind="4" symbol="G01K0007210000" ipcLevel="A" edition="19950101" entryType="K" lang="EN" nocore="yes">
									<textBody>
										<title>
											<titlePart>
												<text>for modifying the output characteristic, e.g. linearising</text>
											</titlePart>
										</title>
									</textBody>
								</ipcEntry>
							</ipcEntry>
						</ipcEntry>
						<ipcEntry kind="2" symbol="G01K0007220000" ipcLevel="A" entryType="K" lang="EN" nocore="yes">
							<textBody>
								<title>
									<titlePart>
										<text>the element being a non-linear resistance, e.g. thermistor</text>
										<entryReference><sref ref="G01K0007260000"/> takes precedence</entryReference>
									</titlePart>
								</title>
							</textBody>
							<ipcEntry kind="3" symbol="G01K0007240000" ipcLevel="A" entryType="K" lang="EN" nocore="yes">
								<textBody>
									<title>
										<titlePart>
											<text>in a specially-adapted circuit, e.g. bridge circuit</text>
										</titlePart>
									</title>
								</textBody>
								<ipcEntry kind="4" symbol="G01K0007250000" ipcLevel="A" edition="19950101" entryType="K" lang="EN" nocore="yes">
									<textBody>
										<title>
											<titlePart>
												<text>for modifying the output characteristic, e.g. linearising</text>
											</titlePart>
										</title>
									</textBody>
								</ipcEntry>
							</ipcEntry>
						</ipcEntry>
						<ipcEntry kind="2" symbol="G01K0007260000" ipcLevel="A" entryType="K" lang="EN" nocore="yes">
							<textBody>
								<title>
									<titlePart>
										<text>the element being an electrolyte</text>
									</titlePart>
								</title>
							</textBody>
							<ipcEntry kind="3" symbol="G01K0007280000" ipcLevel="A" entryType="K" lang="EN" nocore="yes">
								<textBody>
									<title>
										<titlePart>
											<text>in a specially-adapted circuit, e.g. bridge circuit</text>
										</titlePart>
									</title>
								</textBody>
							</ipcEntry>
						</ipcEntry>
					</ipcEntry>
					<ipcEntry kind="1" symbol="G01K0007300000" ipcLevel="C" entryType="K" lang="EN" nocore="yes">
						<textBody>
							<title>
								<titlePart>
									<text>using thermal noise of resistances or conductors</text>
								</titlePart>
							</title>
						</textBody>
					</ipcEntry>
					<ipcEntry kind="1" symbol="G01K0007320000" ipcLevel="C" entryType="K" lang="EN" nocore="yes">
						<textBody>
							<title>
								<titlePart>
									<text>using change of resonant frequency of a crystal</text>
								</titlePart>
							</title>
						</textBody>
					</ipcEntry>
					<ipcEntry kind="1" symbol="G01K0007340000" ipcLevel="C" entryType="K" lang="EN" nocore="yes">
						<textBody>
							<title>
								<titlePart>
									<text>using capacitative elements</text>
									<entryReference>capacitors <u>per se</u><sref ref="H01G"/></entryReference>
								</titlePart>
							</title>
						</textBody>
					</ipcEntry>
					<ipcEntry kind="1" symbol="G01K0007360000" ipcLevel="C" entryType="K" lang="EN" nocore="yes">
						<textBody>
							<title>
								<titlePart>
									<text>using magnetic elements, e.g. magnets, coils</text>
									<entryReference>magnetic elements <u>per se</u><sref ref="H01F"/></entryReference>
								</titlePart>
							</title>
						</textBody>
						<ipcEntry kind="2" symbol="G01K0007380000" ipcLevel="A" entryType="K" lang="EN" nocore="yes">
							<textBody>
								<title>
									<titlePart>
										<text>the variations of temperature influencing the magnetic permeability</text>
									</titlePart>
								</title>
							</textBody>
						</ipcEntry>
					</ipcEntry>
					<ipcEntry kind="1" symbol="G01K0007400000" ipcLevel="C" entryType="K" lang="EN" nocore="yes">
						<textBody>
							<title>
								<titlePart>
									<text>using ionisation of gases</text>
								</titlePart>
							</title>
						</textBody>
					</ipcEntry>
					<ipcEntry kind="1" symbol="G01K0007420000" ipcLevel="C" edition="19950101" entryType="K" lang="EN" nocore="yes">
						<textBody>
							<title>
								<titlePart>
									<text>Circuits for reducing thermal inertia</text>
								</titlePart>
								<titlePart>
									<text>Circuits for predicting the stationary value of temperature</text>
								</titlePart>
							</title>
						</textBody>
					</ipcEntry>
				</ipcEntry>
				<ipcEntry kind="m" symbol="G01K0009000000" ipcLevel="C" entryType="K" lang="EN" priorityOrder="60" nocore="yes">
					<textBody>
						<title>
							<titlePart>
								<text>Measuring temperature based on movements caused by redistribution of weight, e.g. tilting thermometer</text>
								<entryReference>not giving momentary value of temperature <sref ref="G01K0003000000"/></entryReference>
							</titlePart>
						</title>
					</textBody>
				</ipcEntry>
				<ipcEntry kind="m" symbol="G01K0011000000" ipcLevel="C" entryType="K" lang="EN" priorityOrder="80" nocore="yes">
					<textBody>
						<title>
							<titlePart>
								<text>Measuring temperature based on physical or chemical changes not covered by group <sref ref="G01K0003000000"/>, <sref ref="G01K0005000000"/>, <sref ref="G01K0007000000"/>, or <sref ref="G01K0009000000"/></text>
							</titlePart>
						</title>
					</textBody>
					<ipcEntry kind="1" symbol="G01K0011020000" ipcLevel="A" entryType="K" lang="EN" nocore="yes">
						<textBody>
							<title>
								<titlePart>
									<text>using evaporation or sublimation, e.g. by observing boiling</text>
								</titlePart>
							</title>
						</textBody>
						<ipcEntry kind="2" symbol="G01K0011040000" ipcLevel="A" entryType="K" lang="EN" nocore="yes">
							<textBody>
								<title>
									<titlePart>
										<text>from material contained in a hollow body having parts which are deformable or displaceable under the pressure developed by the vapour</text>
									</titlePart>
								</title>
							</textBody>
						</ipcEntry>
					</ipcEntry>
					<ipcEntry kind="1" symbol="G01K0011060000" ipcLevel="A" entryType="K" lang="EN" nocore="yes">
						<textBody>
							<title>
								<titlePart>
									<text>using melting, freezing, or softening</text>
								</titlePart>
							</title>
						</textBody>
						<ipcEntry kind="2" symbol="G01K0011080000" ipcLevel="A" entryType="K" lang="EN" nocore="yes">
							<textBody>
								<title>
									<titlePart>
										<text>of disposable test bodies, e.g. cone</text>
									</titlePart>
								</title>
							</textBody>
						</ipcEntry>
					</ipcEntry>
					<ipcEntry kind="1" symbol="G01K0011100000" ipcLevel="A" entryType="K" lang="EN" nocore="yes">
						<textBody>
							<title>
								<titlePart>
									<text>using sintering</text>
								</titlePart>
							</title>
						</textBody>
					</ipcEntry>
					<ipcEntry kind="1" symbol="G01K0011120000" ipcLevel="A" edition="19950101" entryType="K" lang="EN" nocore="yes">
						<textBody>
							<title>
								<titlePart>
									<text>using change of colour or translucency</text>
									<entryReference><sref ref="G01K0011320000"/> takes precedence</entryReference>
									<entryReference>heat-sensitive sheets for use in thermography <sref ref="B41M0005000000"/></entryReference>
								</titlePart>
							</title>
						</textBody>
						<ipcEntry kind="2" symbol="G01K0011140000" ipcLevel="A" entryType="K" lang="EN" nocore="yes">
							<textBody>
								<title>
									<titlePart>
										<text>of inorganic materials</text>
									</titlePart>
								</title>
							</textBody>
						</ipcEntry>
						<ipcEntry kind="2" symbol="G01K0011160000" ipcLevel="A" entryType="K" lang="EN" nocore="yes">
							<textBody>
								<title>
									<titlePart>
										<text>of organic materials</text>
									</titlePart>
								</title>
							</textBody>
						</ipcEntry>
						<ipcEntry kind="2" symbol="G01K0011180000" ipcLevel="A" entryType="K" lang="EN" nocore="yes">
							<textBody>
								<title>
									<titlePart>
										<text>of materials which change translucency</text>
									</titlePart>
								</title>
							</textBody>
						</ipcEntry>
					</ipcEntry>
					<ipcEntry kind="1" symbol="G01K0011200000" ipcLevel="A" edition="19950101" entryType="K" lang="EN" nocore="yes">
						<textBody>
							<title>
								<titlePart>
									<text>using thermoluminescent materials</text>
									<entryReference><sref ref="G01K0011320000"/> takes precedence</entryReference>
								</titlePart>
							</title>
						</textBody>
					</ipcEntry>
					<ipcEntry kind="1" symbol="G01K0011220000" ipcLevel="A" entryType="K" lang="EN" nocore="yes">
						<textBody>
							<title>
								<titlePart>
									<text>using measurement of acoustic effects</text>
								</titlePart>
							</title>
						</textBody>
						<ipcEntry kind="2" symbol="G01K0011240000" ipcLevel="A" entryType="K" lang="EN" nocore="yes">
							<textBody>
								<title>
									<titlePart>
										<text>of the velocity of propagation of sound</text>
									</titlePart>
								</title>
							</textBody>
						</ipcEntry>
						<ipcEntry kind="2" symbol="G01K0011260000" ipcLevel="A" entryType="K" lang="EN" nocore="yes">
							<textBody>
								<title>
									<titlePart>
										<text>of resonant frequencies</text>
									</titlePart>
								</title>
							</textBody>
						</ipcEntry>
					</ipcEntry>
					<ipcEntry kind="1" symbol="G01K0011280000" ipcLevel="A" entryType="K" lang="EN" nocore="yes">
						<textBody>
							<title>
								<titlePart>
									<text>using measurements of density</text>
									<entryReference>measuring density in general <sref ref="G01N"/></entryReference>
								</titlePart>
							</title>
						</textBody>
					</ipcEntry>
					<ipcEntry kind="1" symbol="G01K0011300000" ipcLevel="A" edition="19900101" entryType="K" lang="EN" nocore="yes">
						<textBody>
							<title>
								<titlePart>
									<text>using measurement of the effect of a material on X-radiation, gamma radiation or particle radiation</text>
								</titlePart>
							</title>
						</textBody>
					</ipcEntry>
					<ipcEntry kind="1" symbol="G01K0011320000" ipcLevel="A" edition="19950101" entryType="K" lang="EN" nocore="yes">
						<textBody>
							<title>
								<titlePart>
									<text>using changes in transmission, scattering or fluorescence in optical fibres</text>
								</titlePart>
							</title>
						</textBody>
					</ipcEntry>
				</ipcEntry>
				<ipcEntry kind="m" symbol="G01K0013000000" ipcLevel="C" entryType="K" lang="EN" priorityOrder="40" nocore="yes">
					<textBody>
						<title>
							<titlePart>
								<text>Adaptations of thermometers for specific purposes</text>
							</titlePart>
						</title>
					</textBody>
					<ipcEntry kind="1" symbol="G01K0013020000" ipcLevel="A" entryType="K" lang="EN" nocore="yes">
						<textBody>
							<title>
								<titlePart>
									<text>for measuring temperature of moving fluids or granular materials capable of flow</text>
								</titlePart>
							</title>
						</textBody>
					</ipcEntry>
					<ipcEntry kind="1" symbol="G01K0013040000" ipcLevel="A" entryType="K" lang="EN" nocore="yes">
						<textBody>
							<title>
								<titlePart>
									<text>for measuring temperature of moving solid bodies</text>
								</titlePart>
							</title>
						</textBody>
						<ipcEntry kind="2" symbol="G01K0013060000" ipcLevel="A" entryType="K" lang="EN" nocore="yes">
							<textBody>
								<title>
									<titlePart>
										<text>in linear movement</text>
									</titlePart>
								</title>
							</textBody>
						</ipcEntry>
						<ipcEntry kind="2" symbol="G01K0013080000" ipcLevel="A" entryType="K" lang="EN" nocore="yes">
							<textBody>
								<title>
									<titlePart>
										<text>in rotary movement</text>
									</titlePart>
								</title>
							</textBody>
						</ipcEntry>
					</ipcEntry>
					<ipcEntry kind="1" symbol="G01K0013100000" ipcLevel="A" entryType="K" lang="EN" nocore="yes">
						<textBody>
							<title>
								<titlePart>
									<text>for measuring temperature within piled or stacked materials</text>
									<entryReference>by special arrangements for conducting heat from the object to the sensitive element <sref ref="G01K0001160000"/></entryReference>
								</titlePart>
							</title>
						</textBody>
					</ipcEntry>
					<ipcEntry kind="1" symbol="G01K0013120000" ipcLevel="A" entryType="K" lang="EN" nocore="yes">
						<textBody>
							<title>
								<titlePart>
									<text>combined with sampling devices for measuring temperatures of samples of material</text>
								</titlePart>
							</title>
						</textBody>
					</ipcEntry>
				</ipcEntry>
				<ipcEntry kind="m" symbol="G01K0015000000" ipcLevel="C" entryType="K" lang="EN" priorityOrder="20" nocore="yes">
					<textBody>
						<title>
							<titlePart>
								<text>Testing or calibrating of thermometers</text>
							</titlePart>
						</title>
					</textBody>
				</ipcEntry>
				<ipcEntry kind="m" symbol="G01K0017000000" ipcLevel="C" entryType="K" lang="EN" priorityOrder="10" nocore="yes">
					<textBody>
						<title>
							<titlePart>
								<text>Measuring quantity of heat</text>
								<entryReference>measuring temperature by calorimetry <mref ref="G01K0003000000" endRef="G01K0011000000"/></entryReference>
								<entryReference>specially adapted for measuring thermal properties of materials, e.g. specific heat, heat of combustion, <sref ref="G01N"/></entryReference>
							</titlePart>
						</title>
					</textBody>
					<ipcEntry kind="1" symbol="G01K0017020000" ipcLevel="A" entryType="K" lang="EN" nocore="yes">
						<textBody>
							<title>
								<titlePart>
									<text>Calorimeters using transport of an indicating substance, e.g. evaporation calorimeters</text>
								</titlePart>
							</title>
						</textBody>
					</ipcEntry>
					<ipcEntry kind="1" symbol="G01K0017040000" ipcLevel="A" entryType="K" lang="EN" nocore="yes">
						<textBody>
							<title>
								<titlePart>
									<text>Calorimeters using compensation methods</text>
								</titlePart>
							</title>
						</textBody>
					</ipcEntry>
					<ipcEntry kind="1" symbol="G01K0017060000" ipcLevel="A" entryType="K" lang="EN" nocore="yes">
						<textBody>
							<title>
								<titlePart>
									<text>Measuring quantity of heat conveyed by flowing media, e.g. in heating systems</text>
									<entryReference><sref ref="G01K0017020000"/>, <sref ref="G01K0017040000"/> take precedence</entryReference>
								</titlePart>
							</title>
						</textBody>
						<ipcEntry kind="2" symbol="G01K0017080000" ipcLevel="A" entryType="K" lang="EN" nocore="yes">
							<textBody>
								<title>
									<titlePart>
										<text>based upon measurement of temperature difference</text>
									</titlePart>
								</title>
							</textBody>
							<ipcEntry kind="3" symbol="G01K0017100000" ipcLevel="A" entryType="K" lang="EN" nocore="yes">
								<textBody>
									<title>
										<titlePart>
											<text>between an inlet and an outlet point, combined with measurement of rate of flow of the medium</text>
										</titlePart>
									</title>
								</textBody>
								<ipcEntry kind="4" symbol="G01K0017120000" ipcLevel="A" entryType="K" lang="EN" nocore="yes">
									<textBody>
										<title>
											<titlePart>
												<text>Indicating product of flow and temperature difference directly</text>
											</titlePart>
										</title>
									</textBody>
									<ipcEntry kind="5" symbol="G01K0017140000" ipcLevel="A" entryType="K" lang="EN" nocore="yes">
										<textBody>
											<title>
												<titlePart>
													<text>using mechanical means for both measurements</text>
												</titlePart>
											</title>
										</textBody>
									</ipcEntry>
									<ipcEntry kind="5" symbol="G01K0017160000" ipcLevel="A" entryType="K" lang="EN" nocore="yes">
										<textBody>
											<title>
												<titlePart>
													<text>using electrical means for both measurements</text>
												</titlePart>
											</title>
										</textBody>
									</ipcEntry>
									<ipcEntry kind="5" symbol="G01K0017180000" ipcLevel="A" entryType="K" lang="EN" nocore="yes">
										<textBody>
											<title>
												<titlePart>
													<text>using electrical means for one measurement and mechanical means for the other</text>
												</titlePart>
											</title>
										</textBody>
									</ipcEntry>
								</ipcEntry>
							</ipcEntry>
							<ipcEntry kind="3" symbol="G01K0017200000" ipcLevel="A" entryType="K" lang="EN" nocore="yes">
								<textBody>
									<title>
										<titlePart>
											<text>across a radiating surface, combined with ascertainment of the heat-transmission coefficient</text>
										</titlePart>
									</title>
								</textBody>
							</ipcEntry>
						</ipcEntry>
					</ipcEntry>
				</ipcEntry>
				<ipcEntry kind="m" symbol="G01K0019000000" ipcLevel="C" entryType="K" lang="EN" priorityOrder="0" nocore="yes">
					<textBody>
						<title>
							<titlePart>
								<text>Testing or calibrating calorimeters</text>
							</titlePart>
						</title>
					</textBody>
				</ipcEntry>
			</ipcEntry>
		</ipcEntry>
	</ipcEntry>
</ipcEntries>
