<?xml version="1.0" encoding="utf-8"?>
<?xml-stylesheet href="ipcentry.xsl" type="text/xsl"?>
<ipcEntries displayMode="e20071001;a20071001;c20060101" ipcLevel="a" split="subclass" languages=",en,fr," size="226332">
	<ipcEntry kind="s" symbol="H" ipcLevel="C" entryType="K" lang="EN" nocore="yes">
		<textBody>
			<title>
				<titlePart>
					<text>SECTION H <emdash/> ELECTRICITY</text>
				</titlePart>
			</title>
		</textBody>
		<ipcEntry kind="n" symbol="H" ipcLevel="C" entryType="K" lang="EN" nocore="yes">
			<textBody>
				<note type="none">
					<noteParagraph>
						<text>These Notes cover the basic principles and general instructions for use of section H.</text>
						<subnote type="Roman" indent="1">
							<noteParagraph>
								<text>Section H <u>covers</u>:</text>
								<subnote type="alpha" indent="2">
									<noteParagraph>
										<text>basic electric elements, which cover all electric units and the general mechanical structure of apparatus and circuits, including the assembly of various basic elements into what are called printed circuits and also cover to a certain extent the manufacture of these elements (when not covered elsewhere);</text>
									</noteParagraph>
									<noteParagraph>
										<text>generation of electricity, which covers the generation, conversion and distribution of electricity together with the controlling of the corresponding gear;</text>
									</noteParagraph>
									<noteParagraph>
										<text>applied electricity, which <u>covers</u>:</text>
										<subnote type="roman" indent="3">
											<noteParagraph>
												<text>general utilisation techniques, viz. those of electric heating and electric lighting circuits;</text>
											</noteParagraph>
											<noteParagraph>
												<text>some special utilisation techniques, either electric or electronic in the strict sense, which are not covered by other sections of the Classification, including:</text>
												<subnote type="number" indent="4">
													<noteParagraph>
														<text>electric light sources, including lasers;</text>
													</noteParagraph>
													<noteParagraph>
														<text>electric X-ray technique;</text>
													</noteParagraph>
													<noteParagraph>
														<text>electric plasma technique and the generation and acceleration of electrically charged particles or neutrons;</text>
													</noteParagraph>
												</subnote>
											</noteParagraph>
										</subnote>
									</noteParagraph>
									<noteParagraph>
										<text>basic electronic circuits and their control;</text>
									</noteParagraph>
									<noteParagraph>
										<text>radio or electric communication technique;</text>
									</noteParagraph>
									<noteParagraph>
										<text>the use of a specified material for the manufacture of the article or element described. In this connection, paragraphs<nbsp/>88 to<nbsp/>90 of the Guide should be referred to.</text>
									</noteParagraph>
								</subnote>
							</noteParagraph>
							<noteParagraph>
								<text>In this section, the following general rules apply: </text>
								<subnote type="alpha" indent="2">
									<noteParagraph>
										<text>Subject to the exceptions stated in I(c), above, any electric aspect or part peculiar to a particular operation, process, apparatus, object or article, classified in one of the sections of the Classification other than section H, is always classified in the subclass for that operation, process, apparatus, object or article. Where common characteristics concerning technical subjects of similar nature have been brought out at class level, the electric aspect or part is classified, in conjunction with the operation, process, apparatus, object or article, in a subclass which covers entirely the general electrical applications for the technical subject in question;</text>
									</noteParagraph>
									<noteParagraph>
										<text>The electrical applications referred to under (a), above, either general or particular, include:</text>
										<subnote type="roman" indent="3">
											<noteParagraph>
												<text>the therapeutic processes and apparatus, in class <sref ref="A61"/>;</text>
											</noteParagraph>
											<noteParagraph>
												<text>the electric processes and apparatus used in various laboratory or industrial operations, in classes <sref ref="B01"/> and <sref ref="B03"/> and in subclass <sref ref="B23K"/>;</text>
											</noteParagraph>
											<noteParagraph>
												<text>the electricity supply, electric propulsion and electric lighting of vehicles in general and of particular vehicles, in the subsection "Transporting" of section B;</text>
											</noteParagraph>
											<noteParagraph>
												<text>the electric ignition systems of internal-combustion engines, in subclass <sref ref="F02P"/>, and of combustion apparatus in general, in subclass <sref ref="F23Q"/>;</text>
											</noteParagraph>
											<noteParagraph>
												<text>the whole electrical part of section G, i.e. measuring devices including apparatus for measuring electric variables, checking, signalling and calculating. Electricity in that section is generally dealt with as a means and not as an end in itself;</text>
											</noteParagraph>
										</subnote>
									</noteParagraph>
									<noteParagraph>
										<text>All electrical applications, both general and particular, presuppose that the "basic electricity" aspect appears in section H (see I(a) above) as regards the electric "basic elements" which they comprise. This rule is also valid for applied electricity, referred to in I(c), above, which appears in section H itself.</text>
									</noteParagraph>
								</subnote>
							</noteParagraph>
							<noteParagraph>
								<text>In this section, the following special cases occur: </text>
								<subnote type="alpha" indent="2">
									<noteParagraph>
										<text>Among the general applications covered by sections other than section H, it is worth noting that electric heating in general is covered by subclasses <sref ref="F24D"/> or <sref ref="F24H"/> or class <sref ref="F27"/>, and that electric lighting in general is partly covered by class <sref ref="F21"/>, since in section H (see I(c), above) there are places in <sref ref="H05B"/> which cover the same technical subjects;</text>
									</noteParagraph>
									<noteParagraph>
										<text>In the two cases referred to under (a), above, the subclasses of section F, which deal with the respective subjects, essentially cover in the first place the whole mechanical aspect of the apparatus or devices, whereas the electrical aspect, as such, is covered by subclass <sref ref="H05B"/>;</text>
									</noteParagraph>
									<noteParagraph>
										<text>In the case of lighting, this mechanical aspect should be taken to cover the material arrangement of the various electric elements, i.e., their geometrical or physical position in relation to one another; this aspect is covered by subclass <sref ref="F21V"/>, the elements themselves and the primary circuits remaining in section H. The same applies to electric light sources, when combined with light sources of a different kind. These are covered by subclass <sref ref="H05B"/>, whereas the physical arrangement which their combination constitutes is covered by the various subclasses of class <sref ref="F21"/>;</text>
									</noteParagraph>
									<noteParagraph>
										<text>As regards heating, not only the electric elements and circuitry designs, as such, are covered by subclass <sref ref="H05B"/>, but also the electric aspects of their arrangement, where these concern cases of general application; electric furnaces being considered as such. The physical disposition of the electric elements in furnaces is covered by section F. If a comparison is made with electric welding circuits, which are covered by subclass <sref ref="B23K"/> in connection with welding, it can be seen that electric heating is not covered by the general rule stated in II, above.</text>
									</noteParagraph>
								</subnote>
							</noteParagraph>
						</subnote>
					</noteParagraph>
				</note>
			</textBody>
		</ipcEntry>
		<ipcEntry kind="c" symbol="H02" ipcLevel="C" entryType="K" lang="EN" nocore="yes">
			<textBody>
				<title>
					<titlePart>
						<text>GENERATION, CONVERSION, OR DISTRIBUTION OF ELECTRIC POWER</text>
					</titlePart>
				</title>
			</textBody>
			<ipcEntry kind="u" symbol="H02K" ipcLevel="C" entryType="K" lang="EN" nocore="yes">
				<textBody>
					<title>
						<titlePart>
							<text>DYNAMO-ELECTRIC MACHINES</text>
							<entryReference>measuring instruments <sref ref="G01"/></entryReference>
							<entryReference>dynamo-electric relays <sref ref="H01H0053000000"/></entryReference>
							<entryReference>conversion of dc or ac input power into surge output power <sref ref="H02M0009000000"/></entryReference>
							<entryReference>loudspeakers, microphones, gramophone pick-ups or like acoustic electromechanical transducers <sref ref="H04R"/></entryReference>
						</titlePart>
					</title>
				</textBody>
				<ipcEntry kind="n" symbol="H02K" ipcLevel="C" entryType="K" lang="EN" nocore="yes">
					<textBody>
						<note type="number">
							<noteParagraph>
								<text>This subclass <u>covers</u> the structural adaptation of the machines for the purposes of their control.</text>
							</noteParagraph>
							<noteParagraph>
								<text>This subclass <u>does not cover</u> starting, regulating, electronically commutating, braking, or otherwise controlling motors, generators or dynamo-electric converters, in general, which are covered by subclass <sref ref="H02P"/>.</text>
							</noteParagraph>
							<noteParagraph edition="20000101">
								<text>Attention is drawn to the Notes following the titles of class <sref ref="B81"/> and subclass <sref ref="B81B"/> relating to "micro-structural devices" and "micro-structural systems".</text>
							</noteParagraph>
						</note>
					</textBody>
				</ipcEntry>
				<ipcEntry kind="i" symbol="H02K" ipcLevel="C" entryType="K" lang="EN" nocore="yes">
					<textBody>
						<index>
							<indexEntry>
								<text>GENERATORS OR MOTORS</text>
								<indexEntry>
									<text>Continuously rotating</text>
									<indexEntry>
										<text>ac machines: asynchronous; synchronous; with mechanical commutator </text>
										<references><sref ref="H02K0017000000"/>; <sref ref="H02K0019000000"/>, <sref ref="H02K0021000000"/>; <sref ref="H02K0027000000"/></references>
									</indexEntry>
									<indexEntry>
										<text>dc machines or universal ac/dc motors: with mechanical commutator; with interrupter </text>
										<references><sref ref="H02K0023000000"/>; <sref ref="H02K0025000000"/></references>
									</indexEntry>
									<indexEntry>
										<text>with non-mechanical commutating devices </text>
										<references><sref ref="H02K0029000000"/></references>
									</indexEntry>
								</indexEntry>
								<indexEntry>
									<text>Acyclic machines; oscillating machines; motors rotating step by step </text>
									<references><sref ref="H02K0031000000"/>; <sref ref="H02K0033000000"/>, <sref ref="H02K0035000000"/>; <sref ref="H02K0037000000"/></references>
								</indexEntry>
								<indexEntry>
									<text>Generators producing a non-sinusoidal waveform </text>
									<references><sref ref="H02K0039000000"/></references>
								</indexEntry>
								<indexEntry>
									<text>Machines with more than one rotor or stator </text>
									<references><sref ref="H02K0016000000"/></references>
								</indexEntry>
							</indexEntry>
							<indexEntry>
								<text>SPECIAL DYNAMO-ELECTRIC APPARATUS</text>
								<indexEntry>
									<text>Machines for transmitting angular displacements; torque motors </text>
									<references><sref ref="H02K0024000000"/>; <sref ref="H02K0026000000"/></references>
								</indexEntry>
								<indexEntry>
									<text>Machines involving dynamo-electric interaction with a plasma or a flow of conductive liquid or of fluid-borne conductive or magnetic particles </text>
									<references><sref ref="H02K0044000000"/></references>
								</indexEntry>
								<indexEntry>
									<text>Systems for propulsing a rigid body along a path </text>
									<references><sref ref="H02K0041000000"/></references>
								</indexEntry>
								<indexEntry>
									<text>Converters </text>
									<references><sref ref="H02K0047000000"/></references>
								</indexEntry>
								<indexEntry>
									<text>Dynamo-electric clutches or brakes; dynamo-electric gears </text>
									<references><sref ref="H02K0049000000"/>; <sref ref="H02K0051000000"/></references>
								</indexEntry>
								<indexEntry>
									<text>Alleged <u>perpetua mobilia</u></text>
									<references><sref ref="H02K0053000000"/></references>
								</indexEntry>
								<indexEntry>
									<text>Machines operating at cryogenic temperatures </text>
									<references><sref ref="H02K0055000000"/></references>
								</indexEntry>
								<indexEntry>
									<text>Machines not otherwise provided for </text>
									<references><sref ref="H02K0057000000"/></references>
								</indexEntry>
							</indexEntry>
							<indexEntry>
								<text>DETAILS</text>
								<indexEntry>
									<text>Magnetic circuits; windings; casings </text>
									<references><sref ref="H02K0001000000"/>; <sref ref="H02K0003000000"/>; <sref ref="H02K0005000000"/></references>
								</indexEntry>
								<indexEntry>
									<text>Arrangements structurally associated with the machine for handling mechanical energy; cooling; measuring or protective devices; current collection or commutation </text>
									<references><sref ref="H02K0007000000"/>; <sref ref="H02K0009000000"/>; <sref ref="H02K0011000000"/>; <sref ref="H02K0013000000"/></references>
								</indexEntry>
							</indexEntry>
							<indexEntry>
								<text>MANUFACTURE </text>
								<references><sref ref="H02K0015000000"/></references>
							</indexEntry>
						</index>
					</textBody>
				</ipcEntry>
				<ipcEntry kind="m" symbol="H02K0001000000" ipcLevel="C" entryType="K" lang="EN" priorityOrder="260" nocore="yes">
					<textBody>
						<title>
							<titlePart>
								<text>Details of the magnetic circuit</text>
								<entryReference>magnetic circuits or magnets in general, magnetic circuits for transformers for power supply <sref ref="H01F"/></entryReference>
								<entryReference>magnetic circuits for relays <sref ref="H01H0050160000"/></entryReference>
							</titlePart>
						</title>
					</textBody>
					<ipcEntry kind="1" symbol="H02K0001020000" ipcLevel="A" entryType="K" lang="EN" nocore="yes">
						<textBody>
							<title>
								<titlePart>
									<text>characterised by the magnetic material</text>
								</titlePart>
							</title>
						</textBody>
					</ipcEntry>
					<ipcEntry kind="1" symbol="H02K0001040000" ipcLevel="A" entryType="K" lang="EN" nocore="yes">
						<textBody>
							<title>
								<titlePart>
									<text>characterised by the material used for insulating the magnetic circuit or parts thereof</text>
									<entryReference>insulation of windings <sref ref="H02K0003300000"/></entryReference>
								</titlePart>
							</title>
						</textBody>
					</ipcEntry>
					<ipcEntry kind="1" symbol="H02K0001060000" ipcLevel="C" entryType="K" lang="EN" nocore="yes">
						<textBody>
							<title>
								<titlePart>
									<text>characterised by the shape, form, or construction</text>
								</titlePart>
							</title>
						</textBody>
						<ipcEntry kind="2" symbol="H02K0001080000" ipcLevel="A" entryType="K" lang="EN" nocore="yes">
							<textBody>
								<title>
									<titlePart>
										<text>Salient poles</text>
									</titlePart>
								</title>
							</textBody>
							<ipcEntry kind="3" symbol="H02K0001100000" ipcLevel="A" entryType="K" lang="EN" nocore="yes">
								<textBody>
									<title>
										<titlePart>
											<text>Commutating poles</text>
										</titlePart>
									</title>
								</textBody>
							</ipcEntry>
						</ipcEntry>
						<ipcEntry kind="2" symbol="H02K0001120000" ipcLevel="C" entryType="K" lang="EN" nocore="yes">
							<textBody>
								<title>
									<titlePart>
										<text>Stationary parts of the magnetic circuit</text>
									</titlePart>
								</title>
							</textBody>
							<ipcEntry kind="3" symbol="H02K0001140000" ipcLevel="C" entryType="K" lang="EN" nocore="yes">
								<textBody>
									<title>
										<titlePart>
											<text>Stator cores with salient poles</text>
										</titlePart>
									</title>
								</textBody>
							</ipcEntry>
							<ipcEntry kind="3" symbol="H02K0001160000" ipcLevel="C" entryType="K" lang="EN" nocore="yes">
								<textBody>
									<title>
										<titlePart>
											<text>Stator cores with slots for windings</text>
										</titlePart>
									</title>
								</textBody>
							</ipcEntry>
							<ipcEntry kind="3" symbol="H02K0001170000" ipcLevel="A" edition="19900101" entryType="K" lang="EN" nocore="yes">
								<textBody>
									<title>
										<titlePart>
											<text>Stator cores with permanent magnets</text>
										</titlePart>
									</title>
								</textBody>
							</ipcEntry>
							<ipcEntry kind="3" symbol="H02K0001180000" ipcLevel="C" entryType="K" lang="EN" nocore="yes">
								<textBody>
									<title>
										<titlePart>
											<text>Means for mounting or fastening magnetic stationary parts on to, or to, the stator structures</text>
										</titlePart>
									</title>
								</textBody>
							</ipcEntry>
							<ipcEntry kind="3" symbol="H02K0001200000" ipcLevel="A" entryType="K" lang="EN" nocore="yes">
								<textBody>
									<title>
										<titlePart>
											<text>with channels or ducts for flow of cooling medium</text>
										</titlePart>
									</title>
								</textBody>
							</ipcEntry>
						</ipcEntry>
						<ipcEntry kind="2" symbol="H02K0001220000" ipcLevel="C" entryType="K" lang="EN" nocore="yes">
							<textBody>
								<title>
									<titlePart>
										<text>Rotating parts of magnetic circuit</text>
									</titlePart>
								</title>
							</textBody>
							<ipcEntry kind="3" symbol="H02K0001240000" ipcLevel="A" entryType="K" lang="EN" nocore="yes">
								<textBody>
									<title>
										<titlePart>
											<text>Rotor cores with salient poles</text>
										</titlePart>
									</title>
								</textBody>
							</ipcEntry>
							<ipcEntry kind="3" symbol="H02K0001260000" ipcLevel="A" entryType="K" lang="EN" nocore="yes">
								<textBody>
									<title>
										<titlePart>
											<text>Rotor cores with slots for windings</text>
										</titlePart>
									</title>
								</textBody>
							</ipcEntry>
							<ipcEntry kind="3" symbol="H02K0001270000" ipcLevel="C" edition="19900101" entryType="K" lang="EN" nocore="yes">
								<textBody>
									<title>
										<titlePart>
											<text>Rotor cores with permanent magnets</text>
										</titlePart>
									</title>
								</textBody>
							</ipcEntry>
							<ipcEntry kind="3" symbol="H02K0001280000" ipcLevel="C" entryType="K" lang="EN" nocore="yes">
								<textBody>
									<title>
										<titlePart>
											<text>Means for mounting or fastening rotating magnetic parts on to, or to, the rotor structures</text>
										</titlePart>
									</title>
								</textBody>
								<ipcEntry kind="4" symbol="H02K0001300000" ipcLevel="A" entryType="K" lang="EN" nocore="yes">
									<textBody>
										<title>
											<titlePart>
												<text>using intermediate part or parts, e.g. spider</text>
											</titlePart>
										</title>
									</textBody>
								</ipcEntry>
							</ipcEntry>
							<ipcEntry kind="3" symbol="H02K0001320000" ipcLevel="C" entryType="K" lang="EN" nocore="yes">
								<textBody>
									<title>
										<titlePart>
											<text>with channels or ducts for flow of cooling medium</text>
										</titlePart>
									</title>
								</textBody>
							</ipcEntry>
						</ipcEntry>
						<ipcEntry kind="2" symbol="H02K0001340000" ipcLevel="A" entryType="K" lang="EN" nocore="yes">
							<textBody>
								<title>
									<titlePart>
										<text>Reciprocating, oscillating, or vibrating part of magnetic circuit</text>
									</titlePart>
								</title>
							</textBody>
						</ipcEntry>
					</ipcEntry>
				</ipcEntry>
				<ipcEntry kind="m" symbol="H02K0003000000" ipcLevel="C" entryType="K" lang="EN" priorityOrder="270" nocore="yes">
					<textBody>
						<title>
							<titlePart>
								<text>Details of windings</text>
								<entryReference>coils in general <sref ref="H01F0005000000"/></entryReference>
							</titlePart>
						</title>
					</textBody>
					<ipcEntry kind="1" symbol="H02K0003020000" ipcLevel="A" entryType="K" lang="EN" nocore="yes">
						<textBody>
							<title>
								<titlePart>
									<text>Windings characterised by the conductor material</text>
									<entryReference>conductors in general <sref ref="H01B0001000000"/>, <sref ref="H01B0005000000"/></entryReference>
								</titlePart>
							</title>
						</textBody>
					</ipcEntry>
					<ipcEntry kind="1" symbol="H02K0003040000" ipcLevel="C" entryType="K" lang="EN" nocore="yes">
						<textBody>
							<title>
								<titlePart>
									<text>Windings characterised by the conductor shape, form, or construction, e.g. with bar conductor</text>
								</titlePart>
							</title>
						</textBody>
						<ipcEntry kind="2" symbol="H02K0003120000" ipcLevel="C" entryType="K" lang="EN" nocore="yes">
							<textBody>
								<title>
									<titlePart>
										<text>arranged in slots</text>
									</titlePart>
								</title>
							</textBody>
							<ipcEntry kind="3" symbol="H02K0003140000" ipcLevel="A" entryType="K" lang="EN" nocore="yes">
								<textBody>
									<title>
										<titlePart>
											<text>with transposed conductors, e.g. twisted conductor</text>
										</titlePart>
									</title>
								</textBody>
							</ipcEntry>
							<ipcEntry kind="3" symbol="H02K0003160000" ipcLevel="A" entryType="K" lang="EN" nocore="yes">
								<textBody>
									<title>
										<titlePart>
											<text>for damping, commutating, or other auxiliary purposes</text>
										</titlePart>
									</title>
								</textBody>
							</ipcEntry>
						</ipcEntry>
						<ipcEntry kind="2" symbol="H02K0003180000" ipcLevel="C" entryType="K" lang="EN" nocore="yes">
							<textBody>
								<title>
									<titlePart>
										<text>Windings for salient poles</text>
									</titlePart>
								</title>
							</textBody>
							<ipcEntry kind="3" symbol="H02K0003200000" ipcLevel="A" entryType="K" lang="EN" nocore="yes">
								<textBody>
									<title>
										<titlePart>
											<text>for damping, commutating, or other auxiliary purposes</text>
										</titlePart>
									</title>
								</textBody>
							</ipcEntry>
						</ipcEntry>
						<ipcEntry kind="2" symbol="H02K0003220000" ipcLevel="A" entryType="K" lang="EN" nocore="yes">
							<textBody>
								<title>
									<titlePart>
										<text>consisting of hollow conductors</text>
									</titlePart>
								</title>
							</textBody>
						</ipcEntry>
						<ipcEntry kind="2" symbol="H02K0003240000" ipcLevel="A" entryType="K" lang="EN" nocore="yes">
							<textBody>
								<title>
									<titlePart>
										<text>with channels or ducts between the conductors for flow of cooling medium</text>
									</titlePart>
								</title>
							</textBody>
						</ipcEntry>
						<ipcEntry kind="2" symbol="H02K0003260000" ipcLevel="A" entryType="K" lang="EN" nocore="yes">
							<textBody>
								<title>
									<titlePart>
										<text>consisting of printed conductors</text>
									</titlePart>
								</title>
							</textBody>
						</ipcEntry>
						<ipcEntry kind="2" symbol="H02K0003280000" ipcLevel="C" entryType="K" lang="EN" nocore="yes">
							<textBody>
								<title>
									<titlePart>
										<text>Layout of windings or of connections between windings</text>
										<entryReference>windings for pole-changing <sref ref="H02K0017060000"/>, <sref ref="H02K0017140000"/>, <sref ref="H02K0019120000"/>, <sref ref="H02K0019320000"/></entryReference>
									</titlePart>
								</title>
							</textBody>
						</ipcEntry>
					</ipcEntry>
					<ipcEntry kind="1" symbol="H02K0003300000" ipcLevel="A" entryType="K" lang="EN" nocore="yes">
						<textBody>
							<title>
								<titlePart>
									<text>Windings characterised by the insulating material</text>
									<entryReference>insulating bodies in general <sref ref="H01B0003000000"/>, <sref ref="H01B0017000000"/></entryReference>
								</titlePart>
							</title>
						</textBody>
					</ipcEntry>
					<ipcEntry kind="1" symbol="H02K0003320000" ipcLevel="C" entryType="K" lang="EN" nocore="yes">
						<textBody>
							<title>
								<titlePart>
									<text>Windings characterised by the shape, form, or construction of the insulation</text>
								</titlePart>
							</title>
						</textBody>
						<ipcEntry kind="2" symbol="H02K0003340000" ipcLevel="A" edition="19800101" entryType="K" lang="EN" nocore="yes">
							<textBody>
								<title>
									<titlePart>
										<text>between conductors or between conductor and core, e.g. slot insulation</text>
									</titlePart>
								</title>
							</textBody>
						</ipcEntry>
						<ipcEntry kind="2" symbol="H02K0003380000" ipcLevel="A" entryType="K" lang="EN" nocore="yes">
							<textBody>
								<title>
									<titlePart>
										<text>around winding heads, equalising connectors, or connections thereto</text>
									</titlePart>
								</title>
							</textBody>
						</ipcEntry>
						<ipcEntry kind="2" symbol="H02K0003400000" ipcLevel="A" entryType="K" lang="EN" nocore="yes">
							<textBody>
								<title>
									<titlePart>
										<text>for high voltage, e.g. affording protection against corona</text>
									</titlePart>
								</title>
							</textBody>
						</ipcEntry>
					</ipcEntry>
					<ipcEntry kind="1" symbol="H02K0003420000" ipcLevel="A" edition="19740701" entryType="K" lang="EN" nocore="yes">
						<textBody>
							<title>
								<titlePart>
									<text>Means for preventing or reducing eddy-current losses in the winding heads, e.g. by shielding</text>
								</titlePart>
							</title>
						</textBody>
					</ipcEntry>
					<ipcEntry kind="1" symbol="H02K0003440000" ipcLevel="A" entryType="K" lang="EN" nocore="yes">
						<textBody>
							<title>
								<titlePart>
									<text>Protection against moisture or chemical attack</text>
								</titlePart>
								<titlePart>
									<text>Windings specially adapted for operation in liquid or gas</text>
								</titlePart>
							</title>
						</textBody>
					</ipcEntry>
					<ipcEntry kind="1" symbol="H02K0003460000" ipcLevel="C" entryType="K" lang="EN" nocore="yes">
						<textBody>
							<title>
								<titlePart>
									<text>Fastening of windings on stator or rotor structure</text>
								</titlePart>
							</title>
						</textBody>
						<ipcEntry kind="2" symbol="H02K0003470000" ipcLevel="A" edition="19800101" entryType="K" lang="EN" nocore="yes">
							<textBody>
								<title>
									<titlePart>
										<text>Air-gap windings, i.e. iron-free windings</text>
									</titlePart>
								</title>
							</textBody>
						</ipcEntry>
						<ipcEntry kind="2" symbol="H02K0003480000" ipcLevel="C" entryType="K" lang="EN" nocore="yes">
							<textBody>
								<title>
									<titlePart>
										<text>in slots</text>
									</titlePart>
								</title>
							</textBody>
							<ipcEntry kind="3" symbol="H02K0003487000" ipcLevel="A" edition="19800101" entryType="K" lang="EN" nocore="yes">
								<textBody>
									<title>
										<titlePart>
											<text>Slot-closing devices</text>
										</titlePart>
									</title>
								</textBody>
								<ipcEntry kind="4" symbol="H02K0003493000" ipcLevel="A" edition="19800101" entryType="K" lang="EN" nocore="yes">
									<textBody>
										<title>
											<titlePart>
												<text>where the devices are magnetic</text>
											</titlePart>
										</title>
									</textBody>
								</ipcEntry>
							</ipcEntry>
						</ipcEntry>
						<ipcEntry kind="2" symbol="H02K0003500000" ipcLevel="C" entryType="K" lang="EN" nocore="yes">
							<textBody>
								<title>
									<titlePart>
										<text>Fastening of winding heads, equalising connectors, or connections thereto</text>
									</titlePart>
								</title>
							</textBody>
							<ipcEntry kind="3" symbol="H02K0003510000" ipcLevel="A" edition="19800101" entryType="K" lang="EN" nocore="yes">
								<textBody>
									<title>
										<titlePart>
											<text>applicable to rotors only</text>
										</titlePart>
									</title>
								</textBody>
							</ipcEntry>
						</ipcEntry>
						<ipcEntry kind="2" symbol="H02K0003520000" ipcLevel="A" entryType="K" lang="EN" nocore="yes">
							<textBody>
								<title>
									<titlePart>
										<text>Fastening salient pole windings or connections thereto</text>
									</titlePart>
								</title>
							</textBody>
						</ipcEntry>
					</ipcEntry>
				</ipcEntry>
				<ipcEntry kind="m" symbol="H02K0005000000" ipcLevel="C" entryType="K" lang="EN" priorityOrder="290" nocore="yes">
					<textBody>
						<title>
							<titlePart>
								<text>Casings</text>
							</titlePart>
							<titlePart>
								<text>Enclosures</text>
							</titlePart>
							<titlePart>
								<text>Supports</text>
								<entryReference>casings for electric apparatus in general <sref ref="H05K0005000000"/></entryReference>
							</titlePart>
						</title>
					</textBody>
					<ipcEntry kind="1" symbol="H02K0005020000" ipcLevel="A" entryType="K" lang="EN" nocore="yes">
						<textBody>
							<title>
								<titlePart>
									<text>Casings or enclosures characterised by the material thereof</text>
								</titlePart>
							</title>
						</textBody>
					</ipcEntry>
					<ipcEntry kind="1" symbol="H02K0005040000" ipcLevel="C" entryType="K" lang="EN" nocore="yes">
						<textBody>
							<title>
								<titlePart>
									<text>Casings or enclosures characterised by the shape, form, or construction thereof</text>
								</titlePart>
							</title>
						</textBody>
						<ipcEntry kind="2" symbol="H02K0005060000" ipcLevel="A" entryType="K" lang="EN" nocore="yes">
							<textBody>
								<title>
									<titlePart>
										<text>Cast metal casings</text>
									</titlePart>
								</title>
							</textBody>
						</ipcEntry>
						<ipcEntry kind="2" symbol="H02K0005080000" ipcLevel="C" entryType="K" lang="EN" nocore="yes">
							<textBody>
								<title>
									<titlePart>
										<text>Insulating casings</text>
									</titlePart>
								</title>
							</textBody>
						</ipcEntry>
						<ipcEntry kind="2" symbol="H02K0005100000" ipcLevel="C" entryType="K" lang="EN" nocore="yes">
							<textBody>
								<title>
									<titlePart>
										<text>affording protection from ingress, e.g. of water, of fingers</text>
									</titlePart>
								</title>
							</textBody>
						</ipcEntry>
						<ipcEntry kind="2" symbol="H02K0005120000" ipcLevel="C" entryType="K" lang="EN" nocore="yes">
							<textBody>
								<title>
									<titlePart>
										<text>specially adapted for operating in liquid or gas</text>
										<entryReference>combined with cooling arrangements <sref ref="H02K0009000000"/></entryReference>
									</titlePart>
								</title>
							</textBody>
							<ipcEntry kind="3" symbol="H02K0005124000" ipcLevel="A" edition="19800101" entryType="K" lang="EN" nocore="yes">
								<textBody>
									<title>
										<titlePart>
											<text>Sealing of the shaft</text>
										</titlePart>
									</title>
								</textBody>
							</ipcEntry>
							<ipcEntry kind="3" symbol="H02K0005128000" ipcLevel="A" edition="19800101" entryType="K" lang="EN" nocore="yes">
								<textBody>
									<title>
										<titlePart>
											<text>using air-gap sleeve or air-gap disc</text>
										</titlePart>
									</title>
								</textBody>
							</ipcEntry>
							<ipcEntry kind="3" symbol="H02K0005132000" ipcLevel="A" edition="19800101" entryType="K" lang="EN" nocore="yes">
								<textBody>
									<title>
										<titlePart>
											<text>Submersible electric motor</text>
											<entryReference><sref ref="H02K0005128000"/> takes precedence</entryReference>
											<entryReference>pumping installations or systems for submerged use <sref ref="F04D0013080000"/></entryReference>
										</titlePart>
									</title>
								</textBody>
							</ipcEntry>
							<ipcEntry kind="3" symbol="H02K0005136000" ipcLevel="A" edition="19800101" entryType="K" lang="EN" nocore="yes">
								<textBody>
									<title>
										<titlePart>
											<text>explosion-proof</text>
										</titlePart>
									</title>
								</textBody>
							</ipcEntry>
						</ipcEntry>
						<ipcEntry kind="2" symbol="H02K0005140000" ipcLevel="C" edition="19800101" entryType="K" lang="EN" nocore="yes">
							<textBody>
								<title>
									<titlePart>
										<text>Means for supporting or protecting brushes or brush holders</text>
									</titlePart>
								</title>
							</textBody>
						</ipcEntry>
						<ipcEntry kind="2" symbol="H02K0005150000" ipcLevel="C" edition="19800101" entryType="K" lang="EN" nocore="yes">
							<textBody>
								<title>
									<titlePart>
										<text>Mounting arrangements for bearing-shields or end plates</text>
									</titlePart>
								</title>
							</textBody>
						</ipcEntry>
						<ipcEntry kind="2" symbol="H02K0005160000" ipcLevel="C" entryType="K" lang="EN" nocore="yes">
							<textBody>
								<title>
									<titlePart>
										<text>Means for supporting bearings, e.g. insulating support, means for fitting the bearing in the bearing-shield</text>
										<entryReference>magnetic bearings <sref ref="H02K0007090000"/></entryReference>
									</titlePart>
								</title>
							</textBody>
							<ipcEntry kind="3" symbol="H02K0005167000" ipcLevel="C" edition="19800101" entryType="K" lang="EN" nocore="yes">
								<textBody>
									<title>
										<titlePart>
											<text>using sliding-contact or spherical cap bearings</text>
										</titlePart>
									</title>
								</textBody>
							</ipcEntry>
							<ipcEntry kind="3" symbol="H02K0005173000" ipcLevel="C" edition="19800101" entryType="K" lang="EN" nocore="yes">
								<textBody>
									<title>
										<titlePart>
											<text>using ball bearings or bearings with rolling contact</text>
										</titlePart>
									</title>
								</textBody>
							</ipcEntry>
						</ipcEntry>
						<ipcEntry kind="2" symbol="H02K0005180000" ipcLevel="A" entryType="K" lang="EN" nocore="yes">
							<textBody>
								<title>
									<titlePart>
										<text>with ribs or fins for improving heat transfer</text>
									</titlePart>
								</title>
							</textBody>
						</ipcEntry>
						<ipcEntry kind="2" symbol="H02K0005200000" ipcLevel="C" entryType="K" lang="EN" nocore="yes">
							<textBody>
								<title>
									<titlePart>
										<text>with channels or ducts for flow of cooling medium</text>
									</titlePart>
								</title>
							</textBody>
						</ipcEntry>
						<ipcEntry kind="2" symbol="H02K0005220000" ipcLevel="C" entryType="K" lang="EN" nocore="yes">
							<textBody>
								<title>
									<titlePart>
										<text>Other additional parts of casings, e.g. shaped to form connection or terminal box</text>
									</titlePart>
								</title>
							</textBody>
						</ipcEntry>
					</ipcEntry>
					<ipcEntry kind="1" symbol="H02K0005240000" ipcLevel="C" entryType="K" lang="EN" nocore="yes">
						<textBody>
							<title>
								<titlePart>
									<text>specially adapted for suppression or reduction of noise or vibration</text>
								</titlePart>
							</title>
						</textBody>
					</ipcEntry>
					<ipcEntry kind="1" symbol="H02K0005260000" ipcLevel="A" entryType="K" lang="EN" nocore="yes">
						<textBody>
							<title>
								<titlePart>
									<text>Means for adjusting the casing relative to its support</text>
								</titlePart>
							</title>
						</textBody>
					</ipcEntry>
				</ipcEntry>
				<ipcEntry kind="m" symbol="H02K0007000000" ipcLevel="C" entryType="K" lang="EN" priorityOrder="0" nocore="yes">
					<textBody>
						<title>
							<titlePart>
								<text>Arrangements for handling mechanical energy structurally associated with the machine, e.g. structural association with mechanical driving motor or auxiliary dynamo-electric machine</text>
							</titlePart>
						</title>
					</textBody>
					<ipcEntry kind="1" symbol="H02K0007020000" ipcLevel="A" entryType="K" lang="EN" nocore="yes">
						<textBody>
							<title>
								<titlePart>
									<text>Additional mass for increasing inertia, e.g. flywheel</text>
								</titlePart>
							</title>
						</textBody>
					</ipcEntry>
					<ipcEntry kind="1" symbol="H02K0007040000" ipcLevel="A" entryType="K" lang="EN" nocore="yes">
						<textBody>
							<title>
								<titlePart>
									<text>Balancing means</text>
								</titlePart>
							</title>
						</textBody>
					</ipcEntry>
					<ipcEntry kind="1" symbol="H02K0007060000" ipcLevel="C" entryType="K" lang="EN" nocore="yes">
						<textBody>
							<title>
								<titlePart>
									<text>Means for converting reciprocating into rotary motion or <u>vice versa</u></text>
								</titlePart>
							</title>
						</textBody>
						<ipcEntry kind="2" symbol="H02K0007065000" ipcLevel="A" edition="19800101" entryType="K" lang="EN" nocore="yes">
							<textBody>
								<title>
									<titlePart>
										<text>Electromechanical oscillators</text>
									</titlePart>
									<titlePart>
										<text>Vibrating magnetic drives</text>
										<entryReference>in time-pieces <sref ref="G04C0005000000"/></entryReference>
									</titlePart>
								</title>
							</textBody>
						</ipcEntry>
						<ipcEntry kind="2" symbol="H02K0007070000" ipcLevel="A" edition="19800101" entryType="K" lang="EN" nocore="yes">
							<textBody>
								<title>
									<titlePart>
										<text>using pawl and ratchet wheel</text>
									</titlePart>
								</title>
							</textBody>
						</ipcEntry>
						<ipcEntry kind="2" symbol="H02K0007075000" ipcLevel="A" edition="19800101" entryType="K" lang="EN" nocore="yes">
							<textBody>
								<title>
									<titlePart>
										<text>using crankshaft or eccentric</text>
									</titlePart>
								</title>
							</textBody>
						</ipcEntry>
					</ipcEntry>
					<ipcEntry kind="1" symbol="H02K0007080000" ipcLevel="C" entryType="K" lang="EN" nocore="yes">
						<textBody>
							<title>
								<titlePart>
									<text>Structural association with bearings</text>
									<entryReference>support in machine casing <sref ref="H02K0005160000"/></entryReference>
								</titlePart>
							</title>
						</textBody>
						<ipcEntry kind="2" symbol="H02K0007090000" ipcLevel="C" edition="19800101" entryType="K" lang="EN" nocore="yes">
							<textBody>
								<title>
									<titlePart>
										<text>with magnetic bearings</text>
									</titlePart>
								</title>
							</textBody>
						</ipcEntry>
					</ipcEntry>
					<ipcEntry kind="1" symbol="H02K0007100000" ipcLevel="C" entryType="K" lang="EN" nocore="yes">
						<textBody>
							<title>
								<titlePart>
									<text>Structural association with clutches, brakes, gears, pulleys, mechanical starters</text>
								</titlePart>
							</title>
						</textBody>
						<ipcEntry kind="2" symbol="H02K0007102000" ipcLevel="A" entryType="K" lang="EN" nocore="yes">
							<textBody>
								<title>
									<titlePart>
										<text>with friction brakes</text>
									</titlePart>
								</title>
							</textBody>
						</ipcEntry>
						<ipcEntry kind="2" symbol="H02K0007104000" ipcLevel="A" entryType="K" lang="EN" nocore="yes">
							<textBody>
								<title>
									<titlePart>
										<text>with eddy-current brakes</text>
									</titlePart>
								</title>
							</textBody>
						</ipcEntry>
						<ipcEntry kind="2" symbol="H02K0007106000" ipcLevel="A" entryType="K" lang="EN" nocore="yes">
							<textBody>
								<title>
									<titlePart>
										<text>with dynamo-electric brakes</text>
									</titlePart>
								</title>
							</textBody>
						</ipcEntry>
						<ipcEntry kind="2" symbol="H02K0007108000" ipcLevel="A" entryType="K" lang="EN" nocore="yes">
							<textBody>
								<title>
									<titlePart>
										<text>with friction clutches</text>
									</titlePart>
								</title>
							</textBody>
						</ipcEntry>
						<ipcEntry kind="2" symbol="H02K0007110000" ipcLevel="A" entryType="K" lang="EN" nocore="yes">
							<textBody>
								<title>
									<titlePart>
										<text>with dynamo-electric clutches</text>
									</titlePart>
								</title>
							</textBody>
						</ipcEntry>
						<ipcEntry kind="2" symbol="H02K0007112000" ipcLevel="A" entryType="K" lang="EN" nocore="yes">
							<textBody>
								<title>
									<titlePart>
										<text>with friction clutches and brakes</text>
									</titlePart>
								</title>
							</textBody>
						</ipcEntry>
						<ipcEntry kind="2" symbol="H02K0007114000" ipcLevel="A" entryType="K" lang="EN" nocore="yes">
							<textBody>
								<title>
									<titlePart>
										<text>with dynamo-electric clutches and brakes</text>
									</titlePart>
								</title>
							</textBody>
						</ipcEntry>
						<ipcEntry kind="2" symbol="H02K0007116000" ipcLevel="C" entryType="K" lang="EN" nocore="yes">
							<textBody>
								<title>
									<titlePart>
										<text>with gears</text>
									</titlePart>
								</title>
							</textBody>
						</ipcEntry>
						<ipcEntry kind="2" symbol="H02K0007118000" ipcLevel="A" entryType="K" lang="EN" nocore="yes">
							<textBody>
								<title>
									<titlePart>
										<text>with starting device</text>
									</titlePart>
								</title>
							</textBody>
						</ipcEntry>
						<ipcEntry kind="2" symbol="H02K0007120000" ipcLevel="A" entryType="K" lang="EN" nocore="yes">
							<textBody>
								<title>
									<titlePart>
										<text>with auxiliary limited movement of stator, rotor, or core parts, e.g. rotor axially movable for the purpose of clutching or braking</text>
									</titlePart>
								</title>
							</textBody>
						</ipcEntry>
					</ipcEntry>
					<ipcEntry kind="1" symbol="H02K0007140000" ipcLevel="C" entryType="K" lang="EN" nocore="yes">
						<textBody>
							<title>
								<titlePart>
									<text>Structural association with mechanical load, e.g. hand-held machine tool, fan</text>
									<entryReference>with fan or impeller for cooling the machine <sref ref="H02K0009060000"/></entryReference>
									<entryReference>for suction cleaners <sref ref="A47L"/></entryReference>
								</titlePart>
							</title>
						</textBody>
						<ipcEntry kind="2" symbol="H02K0007160000" ipcLevel="C" entryType="K" lang="EN" nocore="yes">
							<textBody>
								<title>
									<titlePart>
										<text>for operation above critical speed of vibration of rotating parts</text>
									</titlePart>
								</title>
							</textBody>
						</ipcEntry>
					</ipcEntry>
					<ipcEntry kind="1" symbol="H02K0007180000" ipcLevel="C" entryType="K" lang="EN" nocore="yes">
						<textBody>
							<title>
								<titlePart>
									<text>Structural association of electric generator with mechanical driving motor, e.g. turbine</text>
									<entryReference>if the driving-motor aspect predominates, <u>see</u> the relevant place of section F, e.g. <sref ref="F03B0013000000"/></entryReference>
								</titlePart>
							</title>
						</textBody>
					</ipcEntry>
					<ipcEntry kind="1" symbol="H02K0007200000" ipcLevel="A" entryType="K" lang="EN" nocore="yes">
						<textBody>
							<title>
								<titlePart>
									<text>Structural association with auxiliary dynamo-electric machine, e.g. with electric starter motor, with exciter</text>
								</titlePart>
							</title>
						</textBody>
					</ipcEntry>
				</ipcEntry>
				<ipcEntry kind="m" symbol="H02K0009000000" ipcLevel="C" entryType="K" lang="EN" priorityOrder="280" nocore="yes">
					<textBody>
						<title>
							<titlePart>
								<text>Systems for cooling or ventilating</text>
								<entryReference>channels or ducts in parts of the magnetic circuit <sref ref="H02K0001200000"/>, <sref ref="H02K0001320000"/></entryReference>
								<entryReference>channels or ducts in or between conductors <sref ref="H02K0003220000"/>, <sref ref="H02K0003240000"/></entryReference>
							</titlePart>
						</title>
					</textBody>
					<ipcEntry kind="1" symbol="H02K0009020000" ipcLevel="C" entryType="K" lang="EN" nocore="yes">
						<textBody>
							<title>
								<titlePart>
									<text>by ambient air flowing through the machine</text>
								</titlePart>
							</title>
						</textBody>
						<ipcEntry kind="2" symbol="H02K0009040000" ipcLevel="C" entryType="K" lang="EN" nocore="yes">
							<textBody>
								<title>
									<titlePart>
										<text>having means for generating flow of cooling medium, e.g. having fan</text>
									</titlePart>
								</title>
							</textBody>
							<ipcEntry kind="3" symbol="H02K0009060000" ipcLevel="A" entryType="K" lang="EN" nocore="yes">
								<textBody>
									<title>
										<titlePart>
											<text>with fan or impeller driven by the machine shaft</text>
										</titlePart>
									</title>
								</textBody>
							</ipcEntry>
						</ipcEntry>
					</ipcEntry>
					<ipcEntry kind="1" symbol="H02K0009080000" ipcLevel="A" entryType="K" lang="EN" nocore="yes">
						<textBody>
							<title>
								<titlePart>
									<text>by gaseous cooling medium circulating wholly within the machine casing</text>
									<entryReference><sref ref="H02K0009100000"/> takes precedence</entryReference>
								</titlePart>
							</title>
						</textBody>
					</ipcEntry>
					<ipcEntry kind="1" symbol="H02K0009100000" ipcLevel="A" entryType="K" lang="EN" nocore="yes">
						<textBody>
							<title>
								<titlePart>
									<text>by gaseous cooling medium flowing in closed circuit, a part of which is external to the machine casing</text>
								</titlePart>
							</title>
						</textBody>
						<ipcEntry kind="2" symbol="H02K0009120000" ipcLevel="A" entryType="K" lang="EN" nocore="yes">
							<textBody>
								<title>
									<titlePart>
										<text>wherein the cooling medium circulates freely within the casing</text>
									</titlePart>
								</title>
							</textBody>
						</ipcEntry>
					</ipcEntry>
					<ipcEntry kind="1" symbol="H02K0009140000" ipcLevel="A" entryType="K" lang="EN" nocore="yes">
						<textBody>
							<title>
								<titlePart>
									<text>wherein gaseous cooling medium circulates between the machine casing and a surrounding mantle</text>
								</titlePart>
							</title>
						</textBody>
						<ipcEntry kind="2" symbol="H02K0009160000" ipcLevel="A" entryType="K" lang="EN" nocore="yes">
							<textBody>
								<title>
									<titlePart>
										<text>wherein the cooling medium circulates through ducts or tubes within the casing</text>
									</titlePart>
								</title>
							</textBody>
						</ipcEntry>
						<ipcEntry kind="2" symbol="H02K0009180000" ipcLevel="A" entryType="K" lang="EN" nocore="yes">
							<textBody>
								<title>
									<titlePart>
										<text>wherein the external part of the closed circuit comprises a heat exchanger structurally associated with the machine casing</text>
									</titlePart>
								</title>
							</textBody>
						</ipcEntry>
					</ipcEntry>
					<ipcEntry kind="1" symbol="H02K0009190000" ipcLevel="C" entryType="K" lang="EN" nocore="yes">
						<textBody>
							<title>
								<titlePart>
									<text>for machines with closed casing and with closed-circuit cooling using a liquid cooling medium, e.g. oil</text>
								</titlePart>
							</title>
						</textBody>
						<ipcEntry kind="2" symbol="H02K0009193000" ipcLevel="A" entryType="K" lang="EN" nocore="yes">
							<textBody>
								<title>
									<titlePart>
										<text>with provision for replenishing the cooling medium</text>
									</titlePart>
									<titlePart>
										<text>with means for preventing leakage of the cooling medium</text>
									</titlePart>
								</title>
							</textBody>
						</ipcEntry>
						<ipcEntry kind="2" symbol="H02K0009197000" ipcLevel="A" entryType="K" lang="EN" nocore="yes">
							<textBody>
								<title>
									<titlePart>
										<text>in which the rotor or stator space is fluid-tight, e.g. to provide for different cooling media for rotor and stator</text>
									</titlePart>
								</title>
							</textBody>
						</ipcEntry>
						<ipcEntry kind="2" symbol="H02K0009200000" ipcLevel="A" entryType="K" lang="EN" nocore="yes">
							<textBody>
								<title>
									<titlePart>
										<text>wherein the cooling medium vaporises within the machine casing</text>
									</titlePart>
								</title>
							</textBody>
						</ipcEntry>
					</ipcEntry>
					<ipcEntry kind="1" symbol="H02K0009220000" ipcLevel="C" entryType="K" lang="EN" nocore="yes">
						<textBody>
							<title>
								<titlePart>
									<text>by solid heat conducting material embedded in, or arranged in contact with, stator or rotor, e.g. heat bridge</text>
								</titlePart>
							</title>
						</textBody>
					</ipcEntry>
					<ipcEntry kind="1" symbol="H02K0009240000" ipcLevel="A" entryType="K" lang="EN" nocore="yes">
						<textBody>
							<title>
								<titlePart>
									<text>Protection against failure of cooling arrangements, e.g. due to loss of cooling medium, due to interruption of the circulation of cooling medium</text>
									<entryReference>circuit arrangements affording such protection <sref ref="H02H0007000000"/></entryReference>
								</titlePart>
							</title>
						</textBody>
					</ipcEntry>
					<ipcEntry kind="1" symbol="H02K0009260000" ipcLevel="A" entryType="K" lang="EN" nocore="yes">
						<textBody>
							<title>
								<titlePart>
									<text>Structural association with machine of devices for cleaning or drying cooling medium, e.g. of filter</text>
								</titlePart>
							</title>
						</textBody>
					</ipcEntry>
					<ipcEntry kind="1" symbol="H02K0009280000" ipcLevel="A" entryType="K" lang="EN" nocore="yes">
						<textBody>
							<title>
								<titlePart>
									<text>Cooling of commutators, slip-rings, or brushes, e.g. by ventilating</text>
									<entryReference>current collectors in general <sref ref="H01R0039000000"/></entryReference>
								</titlePart>
							</title>
						</textBody>
					</ipcEntry>
				</ipcEntry>
				<ipcEntry kind="m" symbol="H02K0011000000" ipcLevel="C" entryType="K" lang="EN" priorityOrder="250" nocore="yes">
					<textBody>
						<title>
							<titlePart>
								<text>Structural association with measuring or protective devices or electric components, e.g. with resistor, with switch, with suppressor for radio interference</text>
							</titlePart>
						</title>
					</textBody>
					<ipcEntry kind="1" symbol="H02K0011020000" ipcLevel="C" edition="19950101" entryType="K" lang="EN" nocore="yes">
						<textBody>
							<title>
								<titlePart>
									<text>for suppression of radio interference</text>
								</titlePart>
							</title>
						</textBody>
					</ipcEntry>
					<ipcEntry kind="1" symbol="H02K0011040000" ipcLevel="C" edition="19950101" entryType="K" lang="EN" nocore="yes">
						<textBody>
							<title>
								<titlePart>
									<text>for rectification</text>
								</titlePart>
							</title>
						</textBody>
					</ipcEntry>
				</ipcEntry>
				<ipcEntry kind="m" symbol="H02K0013000000" ipcLevel="C" entryType="K" lang="EN" priorityOrder="240" nocore="yes">
					<textBody>
						<title>
							<titlePart>
								<text>Structural associations of current collectors with motors or generators, e.g. brush mounting plates, connections to windings</text>
								<entryReference>supporting or protecting brushes or brush holders in motor casings or enclosures <sref ref="H02K0005140000"/></entryReference>
							</titlePart>
							<titlePart>
								<text>Disposition of current collectors in motors or generators</text>
							</titlePart>
							<titlePart>
								<text>Arrangements for improving commutation</text>
							</titlePart>
						</title>
					</textBody>
					<ipcEntry kind="1" symbol="H02K0013020000" ipcLevel="C" entryType="K" lang="EN" nocore="yes">
						<textBody>
							<title>
								<titlePart>
									<text>Connections of slip-rings with the winding</text>
								</titlePart>
							</title>
						</textBody>
					</ipcEntry>
					<ipcEntry kind="1" symbol="H02K0013040000" ipcLevel="C" entryType="K" lang="EN" nocore="yes">
						<textBody>
							<title>
								<titlePart>
									<text>Connections of commutator segments with the winding</text>
								</titlePart>
							</title>
						</textBody>
						<ipcEntry kind="2" symbol="H02K0013060000" ipcLevel="A" entryType="K" lang="EN" nocore="yes">
							<textBody>
								<title>
									<titlePart>
										<text>Resistive connections between winding and commutator segments, e.g. by high-resistance choke, by transistor</text>
									</titlePart>
								</title>
							</textBody>
						</ipcEntry>
						<ipcEntry kind="2" symbol="H02K0013080000" ipcLevel="A" entryType="K" lang="EN" nocore="yes">
							<textBody>
								<title>
									<titlePart>
										<text>Segments formed by extensions of winding</text>
									</titlePart>
								</title>
							</textBody>
						</ipcEntry>
					</ipcEntry>
					<ipcEntry kind="1" symbol="H02K0013100000" ipcLevel="C" entryType="K" lang="EN" nocore="yes">
						<textBody>
							<title>
								<titlePart>
									<text>Special arrangements of brushes or commutators for the purpose of improving commutation</text>
								</titlePart>
							</title>
						</textBody>
					</ipcEntry>
					<ipcEntry kind="1" symbol="H02K0013120000" ipcLevel="C" entryType="K" lang="EN" nocore="yes">
						<textBody>
							<title>
								<titlePart>
									<text>Means for producing an axial reciprocation of the rotor and its associated current collector part, e.g. for polishing commutator surface</text>
								</titlePart>
							</title>
						</textBody>
					</ipcEntry>
					<ipcEntry kind="1" symbol="H02K0013140000" ipcLevel="C" entryType="K" lang="EN" nocore="yes">
						<textBody>
							<title>
								<titlePart>
									<text>Circuit arrangements for improvement of commutation, e.g. by use of unidirectionally conductive element</text>
								</titlePart>
							</title>
						</textBody>
					</ipcEntry>
				</ipcEntry>
				<ipcEntry kind="m" symbol="H02K0015000000" ipcLevel="C" entryType="K" lang="EN" priorityOrder="300" nocore="yes">
					<textBody>
						<title>
							<titlePart>
								<text>Methods or apparatus specially adapted for manufacturing, assembling, maintaining, or repairing dynamo-electric machines</text>
								<entryReference>manufacture of current collectors in general <sref ref="H01R0043000000"/></entryReference>
							</titlePart>
						</title>
					</textBody>
					<ipcEntry kind="1" symbol="H02K0015020000" ipcLevel="C" entryType="K" lang="EN" nocore="yes">
						<textBody>
							<title>
								<titlePart>
									<text>of stator or rotor bodies</text>
								</titlePart>
							</title>
						</textBody>
						<ipcEntry kind="2" symbol="H02K0015030000" ipcLevel="C" edition="19900101" entryType="K" lang="EN" nocore="yes">
							<textBody>
								<title>
									<titlePart>
										<text>having permanent magnets</text>
									</titlePart>
								</title>
							</textBody>
						</ipcEntry>
					</ipcEntry>
					<ipcEntry kind="1" symbol="H02K0015040000" ipcLevel="C" entryType="K" lang="EN" nocore="yes">
						<textBody>
							<title>
								<titlePart>
									<text>of windings, prior to mounting into the machine</text>
									<entryReference>insulating windings <sref ref="H02K0015100000"/>, <sref ref="H02K0015120000"/></entryReference>
									<entryReference>coil manufacture in general <sref ref="H01F0041020000"/></entryReference>
								</titlePart>
							</title>
						</textBody>
					</ipcEntry>
					<ipcEntry kind="1" symbol="H02K0015060000" ipcLevel="A" entryType="K" lang="EN" nocore="yes">
						<textBody>
							<title>
								<titlePart>
									<text>Embedding prefabricated windings in the machine</text>
								</titlePart>
							</title>
						</textBody>
					</ipcEntry>
					<ipcEntry kind="1" symbol="H02K0015080000" ipcLevel="C" entryType="K" lang="EN" nocore="yes">
						<textBody>
							<title>
								<titlePart>
									<text>Forming windings by laying conductors into or around core part</text>
								</titlePart>
							</title>
						</textBody>
						<ipcEntry kind="2" symbol="H02K0015085000" ipcLevel="A" entryType="K" lang="EN" nocore="yes">
							<textBody>
								<title>
									<titlePart>
										<text>by laying conductors into slotted stators</text>
									</titlePart>
								</title>
							</textBody>
						</ipcEntry>
						<ipcEntry kind="2" symbol="H02K0015090000" ipcLevel="A" entryType="K" lang="EN" nocore="yes">
							<textBody>
								<title>
									<titlePart>
										<text>by laying conductors into slotted rotors</text>
									</titlePart>
								</title>
							</textBody>
						</ipcEntry>
						<ipcEntry kind="2" symbol="H02K0015095000" ipcLevel="A" entryType="K" lang="EN" nocore="yes">
							<textBody>
								<title>
									<titlePart>
										<text>by laying conductors around salient poles</text>
									</titlePart>
								</title>
							</textBody>
						</ipcEntry>
					</ipcEntry>
					<ipcEntry kind="1" symbol="H02K0015100000" ipcLevel="A" entryType="K" lang="EN" nocore="yes">
						<textBody>
							<title>
								<titlePart>
									<text>Applying solid insulation to the windings, the stator, or the rotor</text>
								</titlePart>
							</title>
						</textBody>
					</ipcEntry>
					<ipcEntry kind="1" symbol="H02K0015120000" ipcLevel="C" entryType="K" lang="EN" nocore="yes">
						<textBody>
							<title>
								<titlePart>
									<text>Impregnating, heating or drying of windings, stators, rotors, or machines</text>
								</titlePart>
							</title>
						</textBody>
					</ipcEntry>
					<ipcEntry kind="1" symbol="H02K0015140000" ipcLevel="C" entryType="K" lang="EN" nocore="yes">
						<textBody>
							<title>
								<titlePart>
									<text>Casings</text>
								</titlePart>
								<titlePart>
									<text>Enclosures</text>
								</titlePart>
								<titlePart>
									<text>Supports</text>
								</titlePart>
							</title>
						</textBody>
					</ipcEntry>
					<ipcEntry kind="1" symbol="H02K0015160000" ipcLevel="A" entryType="K" lang="EN" nocore="yes">
						<textBody>
							<title>
								<titlePart>
									<text>Centering the rotor within the stator</text>
								</titlePart>
								<titlePart>
									<text>Balancing the rotor</text>
									<entryReference>balancing in general <sref ref="G01M"/></entryReference>
								</titlePart>
							</title>
						</textBody>
					</ipcEntry>
				</ipcEntry>
				<ipcEntry kind="m" symbol="H02K0016000000" ipcLevel="C" edition="19740701" entryType="K" lang="EN" priorityOrder="20" nocore="yes">
					<textBody>
						<title>
							<titlePart>
								<text>Machines with more than one rotor or stator</text>
							</titlePart>
						</title>
					</textBody>
					<ipcEntry kind="1" symbol="H02K0016020000" ipcLevel="A" edition="19740701" entryType="K" lang="EN" nocore="yes">
						<textBody>
							<title>
								<titlePart>
									<text>Machines with one stator and two rotors</text>
								</titlePart>
							</title>
						</textBody>
					</ipcEntry>
					<ipcEntry kind="1" symbol="H02K0016040000" ipcLevel="A" edition="19740701" entryType="K" lang="EN" nocore="yes">
						<textBody>
							<title>
								<titlePart>
									<text>Machines with one rotor and two stators</text>
								</titlePart>
							</title>
						</textBody>
					</ipcEntry>
				</ipcEntry>
				<ipcEntry kind="n" symbol="H02K0017000000" endSymbol="H02K0053000000" ipcLevel="C" entryType="K" lang="EN" nocore="yes">
					<textBody>
						<note type="none">
							<noteParagraph edition="19740701">
								<text>Group <sref ref="H02K0016000000"/> takes precedence over groups <mref ref="H02K0017000000" endRef="H02K0053000000"/>.<nbsp/></text>
							</noteParagraph>
						</note>
					</textBody>
				</ipcEntry>
				<ipcEntry kind="m" symbol="H02K0017000000" ipcLevel="C" entryType="K" lang="EN" priorityOrder="210" nocore="yes">
					<textBody>
						<title>
							<titlePart>
								<text>Asynchronous induction motors</text>
							</titlePart>
							<titlePart>
								<text>Asynchronous induction generators</text>
							</titlePart>
						</title>
					</textBody>
					<ipcEntry kind="1" symbol="H02K0017020000" ipcLevel="C" entryType="K" lang="EN" nocore="yes">
						<textBody>
							<title>
								<titlePart>
									<text>Asynchronous induction motors</text>
								</titlePart>
							</title>
						</textBody>
						<ipcEntry kind="2" symbol="H02K0017040000" ipcLevel="A" entryType="K" lang="EN" nocore="yes">
							<textBody>
								<title>
									<titlePart>
										<text>for single phase current</text>
									</titlePart>
								</title>
							</textBody>
							<ipcEntry kind="3" symbol="H02K0017060000" ipcLevel="A" entryType="K" lang="EN" nocore="yes">
								<textBody>
									<title>
										<titlePart>
											<text>having windings arranged for permitting pole-changing</text>
										</titlePart>
									</title>
								</textBody>
							</ipcEntry>
							<ipcEntry kind="3" symbol="H02K0017080000" ipcLevel="A" entryType="K" lang="EN" nocore="yes">
								<textBody>
									<title>
										<titlePart>
											<text>Motors with auxiliary phase obtained by externally fed auxiliary winding, e.g. capacitor motor</text>
										</titlePart>
									</title>
								</textBody>
							</ipcEntry>
							<ipcEntry kind="3" symbol="H02K0017100000" ipcLevel="A" entryType="K" lang="EN" nocore="yes">
								<textBody>
									<title>
										<titlePart>
											<text>Motors with auxiliary phase obtained by split-pole carrying short-circuited winding</text>
										</titlePart>
									</title>
								</textBody>
							</ipcEntry>
						</ipcEntry>
						<ipcEntry kind="2" symbol="H02K0017120000" ipcLevel="A" entryType="K" lang="EN" nocore="yes">
							<textBody>
								<title>
									<titlePart>
										<text>for multi-phase current</text>
									</titlePart>
								</title>
							</textBody>
							<ipcEntry kind="3" symbol="H02K0017140000" ipcLevel="A" entryType="K" lang="EN" nocore="yes">
								<textBody>
									<title>
										<titlePart>
											<text>having windings arranged for permitting pole-changing</text>
										</titlePart>
									</title>
								</textBody>
							</ipcEntry>
						</ipcEntry>
						<ipcEntry kind="2" symbol="H02K0017160000" ipcLevel="C" entryType="K" lang="EN" nocore="yes">
							<textBody>
								<title>
									<titlePart>
										<text>having rotor with internally short-circuited windings, e.g. cage rotor</text>
									</titlePart>
								</title>
							</textBody>
							<ipcEntry kind="3" symbol="H02K0017180000" ipcLevel="A" entryType="K" lang="EN" nocore="yes">
								<textBody>
									<title>
										<titlePart>
											<text>having double- or multiple-cage rotor</text>
										</titlePart>
									</title>
								</textBody>
							</ipcEntry>
							<ipcEntry kind="3" symbol="H02K0017200000" ipcLevel="A" entryType="K" lang="EN" nocore="yes">
								<textBody>
									<title>
										<titlePart>
											<text>having deep-bar rotor</text>
										</titlePart>
									</title>
								</textBody>
							</ipcEntry>
						</ipcEntry>
						<ipcEntry kind="2" symbol="H02K0017220000" ipcLevel="A" entryType="K" lang="EN" nocore="yes">
							<textBody>
								<title>
									<titlePart>
										<text>having rotor with windings connected to slip-rings</text>
									</titlePart>
								</title>
							</textBody>
							<ipcEntry kind="3" symbol="H02K0017240000" ipcLevel="A" entryType="K" lang="EN" nocore="yes">
								<textBody>
									<title>
										<titlePart>
											<text>in which both stator and rotor are fed with ac</text>
										</titlePart>
									</title>
								</textBody>
							</ipcEntry>
						</ipcEntry>
						<ipcEntry kind="2" symbol="H02K0017260000" ipcLevel="A" entryType="K" lang="EN" nocore="yes">
							<textBody>
								<title>
									<titlePart>
										<text>having rotor or stator designed to permit synchronous operation</text>
									</titlePart>
								</title>
							</textBody>
						</ipcEntry>
						<ipcEntry kind="2" symbol="H02K0017280000" ipcLevel="A" entryType="K" lang="EN" nocore="yes">
							<textBody>
								<title>
									<titlePart>
										<text>having compensating winding for improving phase angle</text>
									</titlePart>
								</title>
							</textBody>
						</ipcEntry>
						<ipcEntry kind="2" symbol="H02K0017300000" ipcLevel="A" entryType="K" lang="EN" nocore="yes">
							<textBody>
								<title>
									<titlePart>
										<text>Structural association with auxiliary electric devices influencing the characteristic of, or controlling, the motor, e.g. with impedance, with switch</text>
										<entryReference>control arrangements external to the motor <sref ref="H02P"/></entryReference>
									</titlePart>
								</title>
							</textBody>
						</ipcEntry>
						<ipcEntry kind="2" symbol="H02K0017320000" ipcLevel="A" entryType="K" lang="EN" nocore="yes">
							<textBody>
								<title>
									<titlePart>
										<text>Structural association with auxiliary mechanical devices, e.g. clutch, brake</text>
										<entryReference>control arrangements external to the motor <sref ref="H02P"/></entryReference>
									</titlePart>
								</title>
							</textBody>
						</ipcEntry>
						<ipcEntry kind="2" symbol="H02K0017340000" ipcLevel="A" entryType="K" lang="EN" nocore="yes">
							<textBody>
								<title>
									<titlePart>
										<text>Cascade arrangement of an asynchronous motor with another dynamo-electric motor or converter</text>
										<entryReference>control of cascade arrangements <sref ref="H02P"/></entryReference>
									</titlePart>
								</title>
							</textBody>
							<ipcEntry kind="3" symbol="H02K0017360000" ipcLevel="A" entryType="K" lang="EN" nocore="yes">
								<textBody>
									<title>
										<titlePart>
											<text>with another asynchronous induction motor</text>
										</titlePart>
									</title>
								</textBody>
							</ipcEntry>
							<ipcEntry kind="3" symbol="H02K0017380000" ipcLevel="A" entryType="K" lang="EN" nocore="yes">
								<textBody>
									<title>
										<titlePart>
											<text>with a commutator machine</text>
										</titlePart>
									</title>
								</textBody>
							</ipcEntry>
							<ipcEntry kind="3" symbol="H02K0017400000" ipcLevel="A" entryType="K" lang="EN" nocore="yes">
								<textBody>
									<title>
										<titlePart>
											<text>with a rotary ac/dc converter</text>
											<entryReference>cascade ac/dc converters <sref ref="H02K0047060000"/></entryReference>
										</titlePart>
									</title>
								</textBody>
							</ipcEntry>
						</ipcEntry>
					</ipcEntry>
					<ipcEntry kind="1" symbol="H02K0017420000" ipcLevel="C" edition="19850101" entryType="K" lang="EN" nocore="yes">
						<textBody>
							<title>
								<titlePart>
									<text>Asynchronous induction generators</text>
									<entryReference><sref ref="H02K0017020000"/> takes precedence</entryReference>
								</titlePart>
							</title>
						</textBody>
						<ipcEntry kind="2" symbol="H02K0017440000" ipcLevel="A" entryType="K" lang="EN" nocore="yes">
							<textBody>
								<title>
									<titlePart>
										<text>Structural association with exciting machine</text>
									</titlePart>
								</title>
							</textBody>
						</ipcEntry>
					</ipcEntry>
				</ipcEntry>
				<ipcEntry kind="m" symbol="H02K0019000000" ipcLevel="C" entryType="K" lang="EN" priorityOrder="150" nocore="yes">
					<textBody>
						<title>
							<titlePart>
								<text>Synchronous motors or generators</text>
								<entryReference>having permanent magnet <sref ref="H02K0021000000"/></entryReference>
							</titlePart>
						</title>
					</textBody>
					<ipcEntry kind="1" symbol="H02K0019020000" ipcLevel="C" entryType="K" lang="EN" nocore="yes">
						<textBody>
							<title>
								<titlePart>
									<text>Synchronous motors</text>
								</titlePart>
							</title>
						</textBody>
						<ipcEntry kind="2" symbol="H02K0019040000" ipcLevel="A" entryType="K" lang="EN" nocore="yes">
							<textBody>
								<title>
									<titlePart>
										<text>for single-phase current</text>
									</titlePart>
								</title>
							</textBody>
							<ipcEntry kind="3" symbol="H02K0019060000" ipcLevel="A" entryType="K" lang="EN" nocore="yes">
								<textBody>
									<title>
										<titlePart>
											<text>Motors having windings on the stator and a variable-reluctance soft-iron rotor without windings, e.g. inductor motor</text>
										</titlePart>
									</title>
								</textBody>
							</ipcEntry>
							<ipcEntry kind="3" symbol="H02K0019080000" ipcLevel="A" entryType="K" lang="EN" nocore="yes">
								<textBody>
									<title>
										<titlePart>
											<text>Motors having windings on the stator and a smooth rotor of material with large hysteresis without windings, e.g. hysteresis motor</text>
										</titlePart>
									</title>
								</textBody>
							</ipcEntry>
						</ipcEntry>
						<ipcEntry kind="2" symbol="H02K0019100000" ipcLevel="A" entryType="K" lang="EN" nocore="yes">
							<textBody>
								<title>
									<titlePart>
										<text>for multi-phase current</text>
									</titlePart>
								</title>
							</textBody>
							<ipcEntry kind="3" symbol="H02K0019120000" ipcLevel="A" entryType="K" lang="EN" nocore="yes">
								<textBody>
									<title>
										<titlePart>
											<text>characterised by the arrangement of exciting windings, e.g. for self-excitation, for compounding, for pole-changing</text>
										</titlePart>
									</title>
								</textBody>
							</ipcEntry>
						</ipcEntry>
						<ipcEntry kind="2" symbol="H02K0019140000" ipcLevel="A" entryType="K" lang="EN" nocore="yes">
							<textBody>
								<title>
									<titlePart>
										<text>having additional short-circuited winding for starting as an asynchronous motor</text>
									</titlePart>
								</title>
							</textBody>
						</ipcEntry>
					</ipcEntry>
					<ipcEntry kind="1" symbol="H02K0019160000" ipcLevel="C" entryType="K" lang="EN" nocore="yes">
						<textBody>
							<title>
								<titlePart>
									<text>Synchronous generators</text>
								</titlePart>
							</title>
						</textBody>
						<ipcEntry kind="2" symbol="H02K0019180000" ipcLevel="A" entryType="K" lang="EN" nocore="yes">
							<textBody>
								<title>
									<titlePart>
										<text>having windings each turn of which co-operates only with poles of one polarity, e.g. homopolar generator</text>
									</titlePart>
								</title>
							</textBody>
							<ipcEntry kind="3" symbol="H02K0019200000" ipcLevel="A" entryType="K" lang="EN" nocore="yes">
								<textBody>
									<title>
										<titlePart>
											<text>with variable-reluctance soft-iron rotor without winding</text>
										</titlePart>
									</title>
								</textBody>
							</ipcEntry>
						</ipcEntry>
						<ipcEntry kind="2" symbol="H02K0019220000" ipcLevel="A" entryType="K" lang="EN" nocore="yes">
							<textBody>
								<title>
									<titlePart>
										<text>having windings each turn of which co-operates alternately with poles of opposite polarity, e.g. heteropolar generator</text>
									</titlePart>
								</title>
							</textBody>
							<ipcEntry kind="3" symbol="H02K0019240000" ipcLevel="A" entryType="K" lang="EN" nocore="yes">
								<textBody>
									<title>
										<titlePart>
											<text>with variable-reluctance soft-iron rotor without winding</text>
										</titlePart>
									</title>
								</textBody>
							</ipcEntry>
						</ipcEntry>
						<ipcEntry kind="2" symbol="H02K0019260000" ipcLevel="A" entryType="K" lang="EN" nocore="yes">
							<textBody>
								<title>
									<titlePart>
										<text>characterised by the arrangement of exciting winding</text>
									</titlePart>
								</title>
							</textBody>
							<ipcEntry kind="3" symbol="H02K0019280000" ipcLevel="A" entryType="K" lang="EN" nocore="yes">
								<textBody>
									<title>
										<titlePart>
											<text>for self-excitation</text>
										</titlePart>
									</title>
								</textBody>
							</ipcEntry>
							<ipcEntry kind="3" symbol="H02K0019300000" ipcLevel="A" entryType="K" lang="EN" nocore="yes">
								<textBody>
									<title>
										<titlePart>
											<text>for compounding</text>
										</titlePart>
									</title>
								</textBody>
							</ipcEntry>
							<ipcEntry kind="3" symbol="H02K0019320000" ipcLevel="A" entryType="K" lang="EN" nocore="yes">
								<textBody>
									<title>
										<titlePart>
											<text>for pole-changing</text>
										</titlePart>
									</title>
								</textBody>
							</ipcEntry>
						</ipcEntry>
						<ipcEntry kind="2" symbol="H02K0019340000" ipcLevel="A" entryType="K" lang="EN" nocore="yes">
							<textBody>
								<title>
									<titlePart>
										<text>Generators with two or more outputs</text>
									</titlePart>
								</title>
							</textBody>
						</ipcEntry>
						<ipcEntry kind="2" symbol="H02K0019360000" ipcLevel="A" entryType="K" lang="EN" nocore="yes">
							<textBody>
								<title>
									<titlePart>
										<text>Structural association with auxiliary electric devices influencing the characteristic of, or controlling, the generator, e.g. with impedance, with switch</text>
										<entryReference>control arrangements external to the generator <sref ref="H02P"/></entryReference>
									</titlePart>
								</title>
							</textBody>
						</ipcEntry>
						<ipcEntry kind="2" symbol="H02K0019380000" ipcLevel="A" entryType="K" lang="EN" nocore="yes">
							<textBody>
								<title>
									<titlePart>
										<text>Structural association with exciting machine</text>
									</titlePart>
								</title>
							</textBody>
						</ipcEntry>
					</ipcEntry>
				</ipcEntry>
				<ipcEntry kind="m" symbol="H02K0021000000" ipcLevel="C" entryType="K" lang="EN" priorityOrder="140" nocore="yes">
					<textBody>
						<title>
							<titlePart>
								<text>Synchronous motors having permanent magnet</text>
							</titlePart>
							<titlePart>
								<text>Synchronous generators having permanent magnet</text>
								<entryReference>stator cores with permanent magnets <sref ref="H02K0001170000"/></entryReference>
								<entryReference>rotor cores with permanent magnets <sref ref="H02K0001270000"/></entryReference>
							</titlePart>
						</title>
					</textBody>
					<ipcEntry kind="1" symbol="H02K0021020000" ipcLevel="A" entryType="K" lang="EN" nocore="yes">
						<textBody>
							<title>
								<titlePart>
									<text>Details</text>
								</titlePart>
							</title>
						</textBody>
						<ipcEntry kind="2" symbol="H02K0021040000" ipcLevel="A" entryType="K" lang="EN" nocore="yes">
							<textBody>
								<title>
									<titlePart>
										<text>Windings on magnet for additional excitation</text>
									</titlePart>
								</title>
							</textBody>
						</ipcEntry>
						<ipcEntry kind="2" symbol="H02K0021100000" ipcLevel="A" entryType="K" lang="EN" nocore="yes">
							<textBody>
								<title>
									<titlePart>
										<text>Rotating armatures</text>
									</titlePart>
								</title>
							</textBody>
						</ipcEntry>
					</ipcEntry>
					<ipcEntry kind="1" symbol="H02K0021120000" ipcLevel="C" entryType="K" lang="EN" nocore="yes">
						<textBody>
							<title>
								<titlePart>
									<text>with stationary armature and rotating magnet</text>
								</titlePart>
							</title>
						</textBody>
						<ipcEntry kind="2" symbol="H02K0021140000" ipcLevel="C" entryType="K" lang="EN" nocore="yes">
							<textBody>
								<title>
									<titlePart>
										<text>magnet rotating within armature</text>
									</titlePart>
								</title>
							</textBody>
							<ipcEntry kind="3" symbol="H02K0021160000" ipcLevel="C" entryType="K" lang="EN" nocore="yes">
								<textBody>
									<title>
										<titlePart>
											<text>having an annular armature core with salient poles</text>
											<entryReference>with homopolar co-operation <sref ref="H02K0021200000"/></entryReference>
										</titlePart>
									</title>
								</textBody>
							</ipcEntry>
							<ipcEntry kind="3" symbol="H02K0021180000" ipcLevel="A" entryType="K" lang="EN" nocore="yes">
								<textBody>
									<title>
										<titlePart>
											<text>having horse-shoe armature core</text>
											<entryReference>with homopolar co-operation <sref ref="H02K0021200000"/></entryReference>
										</titlePart>
									</title>
								</textBody>
							</ipcEntry>
							<ipcEntry kind="3" symbol="H02K0021200000" ipcLevel="A" entryType="K" lang="EN" nocore="yes">
								<textBody>
									<title>
										<titlePart>
											<text>having windings each turn of which co-operates only with poles of one polarity, e.g. homopolar machine</text>
										</titlePart>
									</title>
								</textBody>
							</ipcEntry>
						</ipcEntry>
						<ipcEntry kind="2" symbol="H02K0021220000" ipcLevel="C" entryType="K" lang="EN" nocore="yes">
							<textBody>
								<title>
									<titlePart>
										<text>magnet rotating around armature, e.g. flywheel magneto</text>
									</titlePart>
								</title>
							</textBody>
						</ipcEntry>
						<ipcEntry kind="2" symbol="H02K0021240000" ipcLevel="A" entryType="K" lang="EN" nocore="yes">
							<textBody>
								<title>
									<titlePart>
										<text>magnet axially facing armature, e.g. hub-type cycle dynamo</text>
									</titlePart>
								</title>
							</textBody>
						</ipcEntry>
					</ipcEntry>
					<ipcEntry kind="1" symbol="H02K0021260000" ipcLevel="A" entryType="K" lang="EN" nocore="yes">
						<textBody>
							<title>
								<titlePart>
									<text>with rotating armature and stationary magnet</text>
								</titlePart>
							</title>
						</textBody>
						<ipcEntry kind="2" symbol="H02K0021280000" ipcLevel="A" entryType="K" lang="EN" nocore="yes">
							<textBody>
								<title>
									<titlePart>
										<text>armature rotating within magnet</text>
									</titlePart>
								</title>
							</textBody>
							<ipcEntry kind="3" symbol="H02K0021300000" ipcLevel="A" entryType="K" lang="EN" nocore="yes">
								<textBody>
									<title>
										<titlePart>
											<text>having an annular armature core with salient poles</text>
											<entryReference>with homopolar co-operation <sref ref="H02K0021360000"/></entryReference>
										</titlePart>
									</title>
								</textBody>
							</ipcEntry>
							<ipcEntry kind="3" symbol="H02K0021320000" ipcLevel="A" entryType="K" lang="EN" nocore="yes">
								<textBody>
									<title>
										<titlePart>
											<text>having a horse-shoe magnet</text>
											<entryReference>with homopolar co-operation <sref ref="H02K0021360000"/></entryReference>
										</titlePart>
									</title>
								</textBody>
							</ipcEntry>
							<ipcEntry kind="3" symbol="H02K0021340000" ipcLevel="A" entryType="K" lang="EN" nocore="yes">
								<textBody>
									<title>
										<titlePart>
											<text>having bell-shaped or bar-shaped magnet, e.g. for cycle lighting</text>
											<entryReference>with homopolar co-operation <sref ref="H02K0021360000"/></entryReference>
										</titlePart>
									</title>
								</textBody>
							</ipcEntry>
							<ipcEntry kind="3" symbol="H02K0021360000" ipcLevel="A" entryType="K" lang="EN" nocore="yes">
								<textBody>
									<title>
										<titlePart>
											<text>with homopolar co-operation</text>
										</titlePart>
									</title>
								</textBody>
							</ipcEntry>
						</ipcEntry>
					</ipcEntry>
					<ipcEntry kind="1" symbol="H02K0021380000" ipcLevel="A" entryType="K" lang="EN" nocore="yes">
						<textBody>
							<title>
								<titlePart>
									<text>with rotating flux distributor, and armature and magnet both stationary</text>
								</titlePart>
							</title>
						</textBody>
						<ipcEntry kind="2" symbol="H02K0021400000" ipcLevel="A" entryType="K" lang="EN" nocore="yes">
							<textBody>
								<title>
									<titlePart>
										<text>flux distributor rotating around magnet and within armature</text>
									</titlePart>
								</title>
							</textBody>
						</ipcEntry>
						<ipcEntry kind="2" symbol="H02K0021420000" ipcLevel="A" entryType="K" lang="EN" nocore="yes">
							<textBody>
								<title>
									<titlePart>
										<text>flux distributor rotating around armature and within magnet</text>
									</titlePart>
								</title>
							</textBody>
						</ipcEntry>
						<ipcEntry kind="2" symbol="H02K0021440000" ipcLevel="A" entryType="K" lang="EN" nocore="yes">
							<textBody>
								<title>
									<titlePart>
										<text>armature windings wound upon magnet</text>
									</titlePart>
								</title>
							</textBody>
						</ipcEntry>
					</ipcEntry>
					<ipcEntry kind="1" symbol="H02K0021460000" ipcLevel="A" entryType="K" lang="EN" nocore="yes">
						<textBody>
							<title>
								<titlePart>
									<text>Motors having additional short-circuited winding for starting as an asynchronous motor</text>
								</titlePart>
							</title>
						</textBody>
					</ipcEntry>
					<ipcEntry kind="1" symbol="H02K0021480000" ipcLevel="A" entryType="K" lang="EN" nocore="yes">
						<textBody>
							<title>
								<titlePart>
									<text>Generators with two or more outputs</text>
								</titlePart>
							</title>
						</textBody>
					</ipcEntry>
				</ipcEntry>
				<ipcEntry kind="m" symbol="H02K0023000000" ipcLevel="C" entryType="K" lang="EN" priorityOrder="190" nocore="yes">
					<textBody>
						<title>
							<titlePart>
								<text>Dc commutator motors or generators having mechanical commutator</text>
							</titlePart>
							<titlePart>
								<text>Universal ac/dc commutator motors</text>
							</titlePart>
						</title>
					</textBody>
					<ipcEntry kind="1" symbol="H02K0023020000" ipcLevel="C" entryType="K" lang="EN" nocore="yes">
						<textBody>
							<title>
								<titlePart>
									<text>characterised by the exciting arrangement</text>
								</titlePart>
							</title>
						</textBody>
						<ipcEntry kind="2" symbol="H02K0023040000" ipcLevel="A" entryType="K" lang="EN" nocore="yes">
							<textBody>
								<title>
									<titlePart>
										<text>having permanent magnet excitation</text>
									</titlePart>
								</title>
							</textBody>
						</ipcEntry>
						<ipcEntry kind="2" symbol="H02K0023060000" ipcLevel="A" entryType="K" lang="EN" nocore="yes">
							<textBody>
								<title>
									<titlePart>
										<text>having shunt connection of excitation windings</text>
									</titlePart>
								</title>
							</textBody>
						</ipcEntry>
						<ipcEntry kind="2" symbol="H02K0023080000" ipcLevel="A" entryType="K" lang="EN" nocore="yes">
							<textBody>
								<title>
									<titlePart>
										<text>having series connection of excitation windings</text>
									</titlePart>
								</title>
							</textBody>
						</ipcEntry>
						<ipcEntry kind="2" symbol="H02K0023100000" ipcLevel="A" entryType="K" lang="EN" nocore="yes">
							<textBody>
								<title>
									<titlePart>
										<text>having compound connection of excitation windings</text>
									</titlePart>
								</title>
							</textBody>
						</ipcEntry>
						<ipcEntry kind="2" symbol="H02K0023120000" ipcLevel="A" entryType="K" lang="EN" nocore="yes">
							<textBody>
								<title>
									<titlePart>
										<text>having excitation produced by a current source independent of the armature circuit</text>
									</titlePart>
								</title>
							</textBody>
						</ipcEntry>
						<ipcEntry kind="2" symbol="H02K0023140000" ipcLevel="A" entryType="K" lang="EN" nocore="yes">
							<textBody>
								<title>
									<titlePart>
										<text>having high-speed excitation or de-excitation, e.g. by neutralising the remanent excitation field</text>
									</titlePart>
								</title>
							</textBody>
						</ipcEntry>
						<ipcEntry kind="2" symbol="H02K0023160000" ipcLevel="A" entryType="K" lang="EN" nocore="yes">
							<textBody>
								<title>
									<titlePart>
										<text>having angularly adjustable excitation field, e.g. by pole reversing, by pole switching</text>
									</titlePart>
								</title>
							</textBody>
						</ipcEntry>
						<ipcEntry kind="2" symbol="H02K0023180000" ipcLevel="A" entryType="K" lang="EN" nocore="yes">
							<textBody>
								<title>
									<titlePart>
										<text>having displaceable main or auxiliary brushes</text>
									</titlePart>
								</title>
							</textBody>
						</ipcEntry>
						<ipcEntry kind="2" symbol="H02K0023200000" ipcLevel="A" entryType="K" lang="EN" nocore="yes">
							<textBody>
								<title>
									<titlePart>
										<text>having additional brushes spaced intermediately of the main brushes on the commutator, e.g. cross-field machine, metadyne, amplidyne, other armature-reaction excited machine</text>
									</titlePart>
								</title>
							</textBody>
						</ipcEntry>
						<ipcEntry kind="2" symbol="H02K0023220000" ipcLevel="A" entryType="K" lang="EN" nocore="yes">
							<textBody>
								<title>
									<titlePart>
										<text>having compensating or damping winding</text>
									</titlePart>
								</title>
							</textBody>
						</ipcEntry>
						<ipcEntry kind="2" symbol="H02K0023240000" ipcLevel="A" entryType="K" lang="EN" nocore="yes">
							<textBody>
								<title>
									<titlePart>
										<text>having commutating-pole winding</text>
									</titlePart>
								</title>
							</textBody>
						</ipcEntry>
					</ipcEntry>
					<ipcEntry kind="1" symbol="H02K0023260000" ipcLevel="C" entryType="K" lang="EN" nocore="yes">
						<textBody>
							<title>
								<titlePart>
									<text>characterised by the armature winding</text>
								</titlePart>
							</title>
						</textBody>
						<ipcEntry kind="2" symbol="H02K0023280000" ipcLevel="A" entryType="K" lang="EN" nocore="yes">
							<textBody>
								<title>
									<titlePart>
										<text>having open winding, i.e. not closed within armature</text>
									</titlePart>
								</title>
							</textBody>
						</ipcEntry>
						<ipcEntry kind="2" symbol="H02K0023300000" ipcLevel="A" entryType="K" lang="EN" nocore="yes">
							<textBody>
								<title>
									<titlePart>
										<text>having lap winding</text>
									</titlePart>
									<titlePart>
										<text>having loop winding</text>
									</titlePart>
								</title>
							</textBody>
						</ipcEntry>
						<ipcEntry kind="2" symbol="H02K0023320000" ipcLevel="A" entryType="K" lang="EN" nocore="yes">
							<textBody>
								<title>
									<titlePart>
										<text>having wave winding</text>
									</titlePart>
									<titlePart>
										<text>having undulating winding</text>
									</titlePart>
								</title>
							</textBody>
						</ipcEntry>
						<ipcEntry kind="2" symbol="H02K0023340000" ipcLevel="A" entryType="K" lang="EN" nocore="yes">
							<textBody>
								<title>
									<titlePart>
										<text>having mixed windings</text>
									</titlePart>
								</title>
							</textBody>
						</ipcEntry>
						<ipcEntry kind="2" symbol="H02K0023360000" ipcLevel="A" entryType="K" lang="EN" nocore="yes">
							<textBody>
								<title>
									<titlePart>
										<text>having more than one winding</text>
									</titlePart>
									<titlePart>
										<text>having more than one commutator</text>
									</titlePart>
									<titlePart>
										<text>having more than one stator</text>
									</titlePart>
								</title>
							</textBody>
						</ipcEntry>
						<ipcEntry kind="2" symbol="H02K0023380000" ipcLevel="A" entryType="K" lang="EN" nocore="yes">
							<textBody>
								<title>
									<titlePart>
										<text>having winding or connection for improving commutation, e.g. equipotential connection</text>
									</titlePart>
								</title>
							</textBody>
						</ipcEntry>
					</ipcEntry>
					<ipcEntry kind="1" symbol="H02K0023400000" ipcLevel="C" entryType="K" lang="EN" nocore="yes">
						<textBody>
							<title>
								<titlePart>
									<text>characterised by the arrangement of the magnet circuit</text>
								</titlePart>
							</title>
						</textBody>
						<ipcEntry kind="2" symbol="H02K0023420000" ipcLevel="A" entryType="K" lang="EN" nocore="yes">
							<textBody>
								<title>
									<titlePart>
										<text>having split poles, i.e. zones for varying reluctance by gaps in poles or by poles with different spacing of the air gap</text>
									</titlePart>
								</title>
							</textBody>
						</ipcEntry>
						<ipcEntry kind="2" symbol="H02K0023440000" ipcLevel="A" entryType="K" lang="EN" nocore="yes">
							<textBody>
								<title>
									<titlePart>
										<text>having movable or turnable iron parts</text>
									</titlePart>
								</title>
							</textBody>
						</ipcEntry>
						<ipcEntry kind="2" symbol="H02K0023460000" ipcLevel="A" entryType="K" lang="EN" nocore="yes">
							<textBody>
								<title>
									<titlePart>
										<text>having stationary shunts, i.e. magnetic cross flux</text>
									</titlePart>
								</title>
							</textBody>
						</ipcEntry>
						<ipcEntry kind="2" symbol="H02K0023480000" ipcLevel="A" entryType="K" lang="EN" nocore="yes">
							<textBody>
								<title>
									<titlePart>
										<text>having adjustable armature</text>
									</titlePart>
								</title>
							</textBody>
						</ipcEntry>
					</ipcEntry>
					<ipcEntry kind="1" symbol="H02K0023500000" ipcLevel="C" entryType="K" lang="EN" nocore="yes">
						<textBody>
							<title>
								<titlePart>
									<text>Generators with two or more outputs</text>
								</titlePart>
							</title>
						</textBody>
					</ipcEntry>
					<ipcEntry kind="1" symbol="H02K0023520000" ipcLevel="C" entryType="K" lang="EN" nocore="yes">
						<textBody>
							<title>
								<titlePart>
									<text>Motors acting also as generators, e.g. starting motor used as generator for ignition or lighting</text>
								</titlePart>
							</title>
						</textBody>
					</ipcEntry>
					<ipcEntry kind="1" symbol="H02K0023540000" ipcLevel="C" entryType="K" lang="EN" nocore="yes">
						<textBody>
							<title>
								<titlePart>
									<text>Disc armature motors or generators</text>
								</titlePart>
							</title>
						</textBody>
					</ipcEntry>
					<ipcEntry kind="1" symbol="H02K0023560000" ipcLevel="C" entryType="K" lang="EN" nocore="yes">
						<textBody>
							<title>
								<titlePart>
									<text>Motors or generators having the iron core separated from armature winding</text>
								</titlePart>
							</title>
						</textBody>
					</ipcEntry>
					<ipcEntry kind="1" symbol="H02K0023580000" ipcLevel="C" entryType="K" lang="EN" nocore="yes">
						<textBody>
							<title>
								<titlePart>
									<text>Motors or generators having no iron core</text>
								</titlePart>
							</title>
						</textBody>
					</ipcEntry>
					<ipcEntry kind="1" symbol="H02K0023600000" ipcLevel="C" entryType="K" lang="EN" nocore="yes">
						<textBody>
							<title>
								<titlePart>
									<text>Motors or generators having a rotating armature and a rotating excitation field</text>
								</titlePart>
							</title>
						</textBody>
					</ipcEntry>
					<ipcEntry kind="1" symbol="H02K0023620000" ipcLevel="C" entryType="K" lang="EN" nocore="yes">
						<textBody>
							<title>
								<titlePart>
									<text>Motors or generators with stationary armature and rotating excitation field</text>
								</titlePart>
							</title>
						</textBody>
					</ipcEntry>
					<ipcEntry kind="1" symbol="H02K0023640000" ipcLevel="C" entryType="K" lang="EN" nocore="yes">
						<textBody>
							<title>
								<titlePart>
									<text>Motors specially adapted for running on dc or ac by choice</text>
								</titlePart>
							</title>
						</textBody>
					</ipcEntry>
					<ipcEntry kind="1" symbol="H02K0023660000" ipcLevel="C" entryType="K" lang="EN" nocore="yes">
						<textBody>
							<title>
								<titlePart>
									<text>Structural association with auxiliary electric devices influencing the characteristic of, or controlling, the machine, e.g. with impedance, with switch</text>
									<entryReference>control arrangements external to the machine <sref ref="H02P"/></entryReference>
								</titlePart>
							</title>
						</textBody>
					</ipcEntry>
					<ipcEntry kind="1" symbol="H02K0023680000" ipcLevel="A" entryType="K" lang="EN" nocore="yes">
						<textBody>
							<title>
								<titlePart>
									<text>Structural association with auxiliary mechanical devices, e.g. with clutch, with brake</text>
									<entryReference>control arrangements external to the machine <sref ref="H02P"/></entryReference>
								</titlePart>
							</title>
						</textBody>
					</ipcEntry>
				</ipcEntry>
				<ipcEntry kind="m" symbol="H02K0024000000" ipcLevel="C" entryType="K" lang="EN" priorityOrder="80" nocore="yes">
					<textBody>
						<title>
							<titlePart>
								<text>Machines adapted for the instantaneous transmission or reception of the angular displacement of rotating parts, e.g. synchro, selsyn</text>
							</titlePart>
						</title>
					</textBody>
				</ipcEntry>
				<ipcEntry kind="m" symbol="H02K0025000000" ipcLevel="C" entryType="K" lang="EN" priorityOrder="180" nocore="yes">
					<textBody>
						<title>
							<titlePart>
								<text>Dc interrupter motors or generators</text>
							</titlePart>
						</title>
					</textBody>
				</ipcEntry>
				<ipcEntry kind="m" symbol="H02K0026000000" ipcLevel="C" entryType="K" lang="EN" priorityOrder="170" nocore="yes">
					<textBody>
						<title>
							<titlePart>
								<text>Machines adapted to function as torque motors, i.e. to exert a torque when stalled</text>
							</titlePart>
						</title>
					</textBody>
				</ipcEntry>
				<ipcEntry kind="m" symbol="H02K0027000000" ipcLevel="C" entryType="K" lang="EN" priorityOrder="200" nocore="yes">
					<textBody>
						<title>
							<titlePart>
								<text>Ac commutator motors or generators having mechanical commutator</text>
								<entryReference>universal ac/dc motors <sref ref="H02K0023640000"/></entryReference>
							</titlePart>
						</title>
					</textBody>
					<ipcEntry kind="1" symbol="H02K0027020000" ipcLevel="A" entryType="K" lang="EN" nocore="yes">
						<textBody>
							<title>
								<titlePart>
									<text>characterised by the armature winding</text>
								</titlePart>
							</title>
						</textBody>
					</ipcEntry>
					<ipcEntry kind="1" symbol="H02K0027040000" ipcLevel="A" entryType="K" lang="EN" nocore="yes">
						<textBody>
							<title>
								<titlePart>
									<text>having single-phase operation in series or shunt connection</text>
								</titlePart>
							</title>
						</textBody>
						<ipcEntry kind="2" symbol="H02K0027060000" ipcLevel="A" entryType="K" lang="EN" nocore="yes">
							<textBody>
								<title>
									<titlePart>
										<text>with a single or multiple short-circuited commutator, e.g. repulsion motor</text>
									</titlePart>
								</title>
							</textBody>
						</ipcEntry>
						<ipcEntry kind="2" symbol="H02K0027080000" ipcLevel="A" entryType="K" lang="EN" nocore="yes">
							<textBody>
								<title>
									<titlePart>
										<text>with multiple-fed armature</text>
									</titlePart>
								</title>
							</textBody>
						</ipcEntry>
						<ipcEntry kind="2" symbol="H02K0027100000" ipcLevel="A" entryType="K" lang="EN" nocore="yes">
							<textBody>
								<title>
									<titlePart>
										<text>with switching devices for different modes of operation, e.g. repulsion-induction motor</text>
									</titlePart>
								</title>
							</textBody>
						</ipcEntry>
					</ipcEntry>
					<ipcEntry kind="1" symbol="H02K0027120000" ipcLevel="A" entryType="K" lang="EN" nocore="yes">
						<textBody>
							<title>
								<titlePart>
									<text>having multi-phase operation</text>
								</titlePart>
							</title>
						</textBody>
						<ipcEntry kind="2" symbol="H02K0027140000" ipcLevel="A" entryType="K" lang="EN" nocore="yes">
							<textBody>
								<title>
									<titlePart>
										<text>in series connection</text>
									</titlePart>
								</title>
							</textBody>
						</ipcEntry>
						<ipcEntry kind="2" symbol="H02K0027160000" ipcLevel="A" entryType="K" lang="EN" nocore="yes">
							<textBody>
								<title>
									<titlePart>
										<text>in shunt connection with stator feeding</text>
									</titlePart>
								</title>
							</textBody>
						</ipcEntry>
						<ipcEntry kind="2" symbol="H02K0027180000" ipcLevel="A" entryType="K" lang="EN" nocore="yes">
							<textBody>
								<title>
									<titlePart>
										<text>in shunt connection with rotor feeding</text>
									</titlePart>
								</title>
							</textBody>
						</ipcEntry>
					</ipcEntry>
					<ipcEntry kind="1" symbol="H02K0027200000" ipcLevel="A" entryType="K" lang="EN" nocore="yes">
						<textBody>
							<title>
								<titlePart>
									<text>Structural association with a speed regulating device</text>
								</titlePart>
							</title>
						</textBody>
					</ipcEntry>
					<ipcEntry kind="1" symbol="H02K0027220000" ipcLevel="A" entryType="K" lang="EN" nocore="yes">
						<textBody>
							<title>
								<titlePart>
									<text>having means for improving commutation, e.g. auxiliary fields, double windings, double brushes</text>
								</titlePart>
							</title>
						</textBody>
					</ipcEntry>
					<ipcEntry kind="1" symbol="H02K0027240000" ipcLevel="A" entryType="K" lang="EN" nocore="yes">
						<textBody>
							<title>
								<titlePart>
									<text>having two or more commutators</text>
								</titlePart>
							</title>
						</textBody>
					</ipcEntry>
					<ipcEntry kind="1" symbol="H02K0027260000" ipcLevel="A" entryType="K" lang="EN" nocore="yes">
						<textBody>
							<title>
								<titlePart>
									<text>having disc armature</text>
								</titlePart>
							</title>
						</textBody>
					</ipcEntry>
					<ipcEntry kind="1" symbol="H02K0027280000" ipcLevel="A" entryType="K" lang="EN" nocore="yes">
						<textBody>
							<title>
								<titlePart>
									<text>Structural association with auxiliary electric devices influencing the characteristic of, or controlling, the machine</text>
									<entryReference>control arrangements external to the machine <sref ref="H02P"/></entryReference>
								</titlePart>
							</title>
						</textBody>
					</ipcEntry>
					<ipcEntry kind="1" symbol="H02K0027300000" ipcLevel="A" entryType="K" lang="EN" nocore="yes">
						<textBody>
							<title>
								<titlePart>
									<text>Structural association with auxiliary mechanical devices, e.g. clutch, brake</text>
									<entryReference>control arrangements external to the machine <sref ref="H02P"/></entryReference>
								</titlePart>
							</title>
						</textBody>
					</ipcEntry>
				</ipcEntry>
				<ipcEntry kind="m" symbol="H02K0029000000" ipcLevel="C" entryType="K" lang="EN" priorityOrder="70" nocore="yes">
					<textBody>
						<title>
							<titlePart>
								<text>Motors or generators having non-mechanical commutating devices, e.g. discharge tubes, semiconductor devices</text>
							</titlePart>
						</title>
					</textBody>
					<ipcEntry kind="1" symbol="H02K0029030000" ipcLevel="C" edition="19950101" entryType="K" lang="EN" nocore="yes">
						<textBody>
							<title>
								<titlePart>
									<text>with a magnetic circuit specially adapted for avoiding torque ripples or self-starting problems</text>
								</titlePart>
							</title>
						</textBody>
					</ipcEntry>
					<ipcEntry kind="1" symbol="H02K0029060000" ipcLevel="C" edition="19850101,19950101" entryType="K" lang="EN" nocore="yes">
						<textBody>
							<title>
								<titlePart>
									<text>with position sensing devices</text>
									<entryReference><sref ref="H02K0029030000"/> takes precedence</entryReference>
								</titlePart>
							</title>
						</textBody>
						<ipcEntry kind="2" symbol="H02K0029080000" ipcLevel="A" edition="19850101" entryType="K" lang="EN" nocore="yes">
							<textBody>
								<title>
									<titlePart>
										<text>using magnetic effect devices, e.g. Hall-plates, magneto-resistors</text>
										<entryReference><sref ref="H02K0029120000"/> takes precedence</entryReference>
									</titlePart>
								</title>
							</textBody>
						</ipcEntry>
						<ipcEntry kind="2" symbol="H02K0029100000" ipcLevel="A" edition="19850101" entryType="K" lang="EN" nocore="yes">
							<textBody>
								<title>
									<titlePart>
										<text>using light effect devices</text>
									</titlePart>
								</title>
							</textBody>
						</ipcEntry>
						<ipcEntry kind="2" symbol="H02K0029120000" ipcLevel="A" edition="19850101" entryType="K" lang="EN" nocore="yes">
							<textBody>
								<title>
									<titlePart>
										<text>using detecting coils</text>
									</titlePart>
								</title>
							</textBody>
						</ipcEntry>
					</ipcEntry>
					<ipcEntry kind="1" symbol="H02K0029140000" ipcLevel="C" edition="19850101,19950101" entryType="K" lang="EN" nocore="yes">
						<textBody>
							<title>
								<titlePart>
									<text>with speed sensing devices</text>
									<entryReference><sref ref="H02K0029030000"/> takes precedence</entryReference>
								</titlePart>
							</title>
						</textBody>
					</ipcEntry>
				</ipcEntry>
				<ipcEntry kind="m" symbol="H02K0031000000" ipcLevel="C" entryType="K" lang="EN" priorityOrder="160" nocore="yes">
					<textBody>
						<title>
							<titlePart>
								<text>Acyclic motors or generators, i.e. dc machines having a drum or disc armature with continuous current collectors</text>
							</titlePart>
						</title>
					</textBody>
					<ipcEntry kind="1" symbol="H02K0031020000" ipcLevel="A" entryType="K" lang="EN" nocore="yes">
						<textBody>
							<title>
								<titlePart>
									<text>with solid-contact collectors</text>
								</titlePart>
							</title>
						</textBody>
					</ipcEntry>
					<ipcEntry kind="1" symbol="H02K0031040000" ipcLevel="A" entryType="K" lang="EN" nocore="yes">
						<textBody>
							<title>
								<titlePart>
									<text>with at least one liquid-contact collector</text>
								</titlePart>
							</title>
						</textBody>
					</ipcEntry>
				</ipcEntry>
				<ipcEntry kind="m" symbol="H02K0033000000" ipcLevel="C" entryType="K" lang="EN" priorityOrder="100" nocore="yes">
					<textBody>
						<title>
							<titlePart>
								<text>Motors with reciprocating, oscillating, or vibrating magnet, armature, or coil system</text>
								<entryReference>arrangements for handling mechanical energy structurally associated with motors <sref ref="H02K0007000000"/>, e.g. <sref ref="H02K0007060000"/></entryReference>
							</titlePart>
						</title>
					</textBody>
					<ipcEntry kind="1" symbol="H02K0033020000" ipcLevel="A" entryType="K" lang="EN" nocore="yes">
						<textBody>
							<title>
								<titlePart>
									<text>with armature moved one way by energisation of a single coil system and returned by mechanical force, e.g. by spring</text>
								</titlePart>
							</title>
						</textBody>
						<ipcEntry kind="2" symbol="H02K0033040000" ipcLevel="A" entryType="K" lang="EN" nocore="yes">
							<textBody>
								<title>
									<titlePart>
										<text>wherein the frequency of operation is determined by the frequency of uninterrupted ac energisation</text>
									</titlePart>
								</title>
							</textBody>
							<ipcEntry kind="3" symbol="H02K0033060000" ipcLevel="A" entryType="K" lang="EN" nocore="yes">
								<textBody>
									<title>
										<titlePart>
											<text>with polarised armature</text>
										</titlePart>
									</title>
								</textBody>
							</ipcEntry>
							<ipcEntry kind="3" symbol="H02K0033080000" ipcLevel="A" entryType="K" lang="EN" nocore="yes">
								<textBody>
									<title>
										<titlePart>
											<text>with dc energisation superimposed on ac energisation</text>
										</titlePart>
									</title>
								</textBody>
							</ipcEntry>
						</ipcEntry>
						<ipcEntry kind="2" symbol="H02K0033100000" ipcLevel="A" entryType="K" lang="EN" nocore="yes">
							<textBody>
								<title>
									<titlePart>
										<text>wherein the alternate energisation and de-energisation of the single coil system is effected or controlled by movement of the armature</text>
									</titlePart>
								</title>
							</textBody>
						</ipcEntry>
					</ipcEntry>
					<ipcEntry kind="1" symbol="H02K0033120000" ipcLevel="A" entryType="K" lang="EN" nocore="yes">
						<textBody>
							<title>
								<titlePart>
									<text>with armature moving in alternate directions by alternate energisation of two coil systems</text>
								</titlePart>
							</title>
						</textBody>
						<ipcEntry kind="2" symbol="H02K0033140000" ipcLevel="A" entryType="K" lang="EN" nocore="yes">
							<textBody>
								<title>
									<titlePart>
										<text>wherein the alternate energisation and de-energisation of the two coil systems are effected or controlled by movement of the armature</text>
									</titlePart>
								</title>
							</textBody>
						</ipcEntry>
					</ipcEntry>
					<ipcEntry kind="1" symbol="H02K0033160000" ipcLevel="A" entryType="K" lang="EN" nocore="yes">
						<textBody>
							<title>
								<titlePart>
									<text>with polarised armature moving in alternate directions by reversal or energisation of a single coil system</text>
								</titlePart>
							</title>
						</textBody>
					</ipcEntry>
					<ipcEntry kind="1" symbol="H02K0033180000" ipcLevel="C" entryType="K" lang="EN" nocore="yes">
						<textBody>
							<title>
								<titlePart>
									<text>with coil system moving upon intermittent or reversed energisation thereof by interaction with a fixed field system, e.g. permanent magnet</text>
								</titlePart>
							</title>
						</textBody>
					</ipcEntry>
				</ipcEntry>
				<ipcEntry kind="m" symbol="H02K0035000000" ipcLevel="C" entryType="K" lang="EN" priorityOrder="110" nocore="yes">
					<textBody>
						<title>
							<titlePart>
								<text>Generators with reciprocating, oscillating, or vibrating coil system, magnet, armature, or other part of the magnetic circuit</text>
								<entryReference>arrangements for handling mechanical energy structurally associated with generators <sref ref="H02K0007000000"/>, e.g. <sref ref="H02K0007060000"/></entryReference>
							</titlePart>
						</title>
					</textBody>
					<ipcEntry kind="1" symbol="H02K0035020000" ipcLevel="A" entryType="K" lang="EN" nocore="yes">
						<textBody>
							<title>
								<titlePart>
									<text>with moving magnet and stationary coil system</text>
								</titlePart>
							</title>
						</textBody>
					</ipcEntry>
					<ipcEntry kind="1" symbol="H02K0035040000" ipcLevel="A" entryType="K" lang="EN" nocore="yes">
						<textBody>
							<title>
								<titlePart>
									<text>with moving coil system and stationary magnet</text>
								</titlePart>
							</title>
						</textBody>
					</ipcEntry>
					<ipcEntry kind="1" symbol="H02K0035060000" ipcLevel="A" entryType="K" lang="EN" nocore="yes">
						<textBody>
							<title>
								<titlePart>
									<text>with moving flux distributor, and both coil system and magnet stationary</text>
								</titlePart>
							</title>
						</textBody>
					</ipcEntry>
				</ipcEntry>
				<ipcEntry kind="m" symbol="H02K0037000000" ipcLevel="C" entryType="K" lang="EN" priorityOrder="130" nocore="yes">
					<textBody>
						<title>
							<titlePart>
								<text>Motors with rotor rotating step by step and without interrupter or commutator driven by the rotor, e.g. stepping motors</text>
							</titlePart>
						</title>
					</textBody>
					<ipcEntry kind="1" symbol="H02K0037020000" ipcLevel="C" edition="19850101" entryType="K" lang="EN" nocore="yes">
						<textBody>
							<title>
								<titlePart>
									<text>variable reluctance type</text>
								</titlePart>
							</title>
						</textBody>
						<ipcEntry kind="2" symbol="H02K0037040000" ipcLevel="A" edition="19850101" entryType="K" lang="EN" nocore="yes">
							<textBody>
								<title>
									<titlePart>
										<text>Rotor situated within stator</text>
									</titlePart>
								</title>
							</textBody>
						</ipcEntry>
						<ipcEntry kind="2" symbol="H02K0037060000" ipcLevel="A" edition="19850101" entryType="K" lang="EN" nocore="yes">
							<textBody>
								<title>
									<titlePart>
										<text>Rotor situated around stator</text>
									</titlePart>
								</title>
							</textBody>
						</ipcEntry>
						<ipcEntry kind="2" symbol="H02K0037080000" ipcLevel="A" edition="19850101" entryType="K" lang="EN" nocore="yes">
							<textBody>
								<title>
									<titlePart>
										<text>Rotor axially facing stator</text>
									</titlePart>
								</title>
							</textBody>
						</ipcEntry>
					</ipcEntry>
					<ipcEntry kind="1" symbol="H02K0037100000" ipcLevel="C" edition="19850101" entryType="K" lang="EN" nocore="yes">
						<textBody>
							<title>
								<titlePart>
									<text>permanent magnet type</text>
									<entryReference><sref ref="H02K0037020000"/> takes precedence</entryReference>
								</titlePart>
							</title>
						</textBody>
						<ipcEntry kind="2" symbol="H02K0037120000" ipcLevel="C" edition="19850101" entryType="K" lang="EN" nocore="yes">
							<textBody>
								<title>
									<titlePart>
										<text>with stationary armature and rotating magnet</text>
									</titlePart>
								</title>
							</textBody>
							<ipcEntry kind="3" symbol="H02K0037140000" ipcLevel="A" edition="19850101" entryType="K" lang="EN" nocore="yes">
								<textBody>
									<title>
										<titlePart>
											<text>Magnet rotating within armature</text>
										</titlePart>
									</title>
								</textBody>
								<ipcEntry kind="4" symbol="H02K0037160000" ipcLevel="A" edition="19850101" entryType="K" lang="EN" nocore="yes">
									<textBody>
										<title>
											<titlePart>
												<text>having horseshoe armature core</text>
											</titlePart>
										</title>
									</textBody>
								</ipcEntry>
								<ipcEntry kind="4" symbol="H02K0037180000" ipcLevel="A" edition="19850101" entryType="K" lang="EN" nocore="yes">
									<textBody>
										<title>
											<titlePart>
												<text>homopolar type</text>
											</titlePart>
										</title>
									</textBody>
								</ipcEntry>
							</ipcEntry>
						</ipcEntry>
						<ipcEntry kind="2" symbol="H02K0037200000" ipcLevel="A" edition="19850101" entryType="K" lang="EN" nocore="yes">
							<textBody>
								<title>
									<titlePart>
										<text>with rotating flux distributor, the armature and magnet both being stationary</text>
									</titlePart>
								</title>
							</textBody>
						</ipcEntry>
					</ipcEntry>
					<ipcEntry kind="1" symbol="H02K0037220000" ipcLevel="A" edition="19850101" entryType="K" lang="EN" nocore="yes">
						<textBody>
							<title>
								<titlePart>
									<text>Damping units</text>
								</titlePart>
							</title>
						</textBody>
					</ipcEntry>
					<ipcEntry kind="1" symbol="H02K0037240000" ipcLevel="A" edition="19850101" entryType="K" lang="EN" nocore="yes">
						<textBody>
							<title>
								<titlePart>
									<text>Structural association with auxiliary mechanical devices</text>
								</titlePart>
							</title>
						</textBody>
					</ipcEntry>
				</ipcEntry>
				<ipcEntry kind="m" symbol="H02K0039000000" ipcLevel="C" entryType="K" lang="EN" priorityOrder="120" nocore="yes">
					<textBody>
						<title>
							<titlePart>
								<text>Generators specially adapted for producing a desired non-sinusoidal waveform</text>
							</titlePart>
						</title>
					</textBody>
				</ipcEntry>
				<ipcEntry kind="m" symbol="H02K0041000000" ipcLevel="C" entryType="K" lang="EN" priorityOrder="90" nocore="yes">
					<textBody>
						<title>
							<titlePart>
								<text>Propulsion systems in which a rigid body is moved along a path due to dynamo-electric interaction between the body and a magnetic field travelling along the path</text>
							</titlePart>
						</title>
					</textBody>
					<ipcEntry kind="1" symbol="H02K0041020000" ipcLevel="C" edition="19800101" entryType="K" lang="EN" nocore="yes">
						<textBody>
							<title>
								<titlePart>
									<text>Linear motors</text>
								</titlePart>
								<titlePart>
									<text>Sectional motors</text>
								</titlePart>
							</title>
						</textBody>
						<ipcEntry kind="2" symbol="H02K0041025000" ipcLevel="C" edition="19800101" entryType="K" lang="EN" nocore="yes">
							<textBody>
								<title>
									<titlePart>
										<text>Asynchronous motors</text>
									</titlePart>
								</title>
							</textBody>
						</ipcEntry>
						<ipcEntry kind="2" symbol="H02K0041030000" ipcLevel="C" edition="19800101" entryType="K" lang="EN" nocore="yes">
							<textBody>
								<title>
									<titlePart>
										<text>Synchronous motors</text>
									</titlePart>
									<titlePart>
										<text>Motors moving step by step</text>
									</titlePart>
									<titlePart>
										<text>Reluctance motors</text>
										<entryReference><sref ref="H02K0041035000"/> takes precedence</entryReference>
									</titlePart>
								</title>
							</textBody>
						</ipcEntry>
						<ipcEntry kind="2" symbol="H02K0041035000" ipcLevel="C" edition="19800101" entryType="K" lang="EN" nocore="yes">
							<textBody>
								<title>
									<titlePart>
										<text>Dc motors</text>
									</titlePart>
									<titlePart>
										<text>Unipolar motors</text>
									</titlePart>
								</title>
							</textBody>
						</ipcEntry>
					</ipcEntry>
					<ipcEntry kind="1" symbol="H02K0041060000" ipcLevel="A" entryType="K" lang="EN" nocore="yes">
						<textBody>
							<title>
								<titlePart>
									<text>Rolling motors, i.e. having the rotor axis parallel to the stator axis and following a circular path as the rotor rolls around the inside or outside of the stator</text>
								</titlePart>
							</title>
						</textBody>
					</ipcEntry>
				</ipcEntry>
				<ipcEntry kind="m" symbol="H02K0044000000" ipcLevel="C" edition="19800101" entryType="K" lang="EN" priorityOrder="30" nocore="yes">
					<textBody>
						<title>
							<titlePart>
								<text>Machines in which the dynamo-electric interaction between a plasma or flow of conductive liquid or of fluid-borne conductive or magnetic particles and a coil system or magnetic field converts energy of mass flow into electrical energy or <u>vice versa</u></text>
							</titlePart>
						</title>
					</textBody>
					<ipcEntry kind="1" symbol="H02K0044020000" ipcLevel="A" edition="19800101" entryType="K" lang="EN" nocore="yes">
						<textBody>
							<title>
								<titlePart>
									<text>Electrodynamic pumps</text>
								</titlePart>
							</title>
						</textBody>
						<ipcEntry kind="2" symbol="H02K0044040000" ipcLevel="A" edition="19800101" entryType="K" lang="EN" nocore="yes">
							<textBody>
								<title>
									<titlePart>
										<text>Conduction pumps</text>
									</titlePart>
								</title>
							</textBody>
						</ipcEntry>
						<ipcEntry kind="2" symbol="H02K0044060000" ipcLevel="A" edition="19800101" entryType="K" lang="EN" nocore="yes">
							<textBody>
								<title>
									<titlePart>
										<text>Induction pumps</text>
									</titlePart>
								</title>
							</textBody>
						</ipcEntry>
					</ipcEntry>
					<ipcEntry kind="1" symbol="H02K0044080000" ipcLevel="A" edition="19800101" entryType="K" lang="EN" nocore="yes">
						<textBody>
							<title>
								<titlePart>
									<text>Magnetohydrodynamic (MHD) generators</text>
								</titlePart>
							</title>
						</textBody>
						<ipcEntry kind="2" symbol="H02K0044100000" ipcLevel="A" edition="19800101" entryType="K" lang="EN" nocore="yes">
							<textBody>
								<title>
									<titlePart>
										<text>Constructional details of electrodes</text>
									</titlePart>
								</title>
							</textBody>
						</ipcEntry>
						<ipcEntry kind="2" symbol="H02K0044120000" ipcLevel="A" edition="19800101" entryType="K" lang="EN" nocore="yes">
							<textBody>
								<title>
									<titlePart>
										<text>Constructional details of fluid channel</text>
									</titlePart>
								</title>
							</textBody>
							<ipcEntry kind="3" symbol="H02K0044140000" ipcLevel="A" edition="19800101" entryType="K" lang="EN" nocore="yes">
								<textBody>
									<title>
										<titlePart>
											<text>Circular or screw-shaped channel</text>
										</titlePart>
									</title>
								</textBody>
							</ipcEntry>
						</ipcEntry>
						<ipcEntry kind="2" symbol="H02K0044160000" ipcLevel="A" edition="19800101" entryType="K" lang="EN" nocore="yes">
							<textBody>
								<title>
									<titlePart>
										<text>Constructional details of the magnetic circuit</text>
									</titlePart>
								</title>
							</textBody>
						</ipcEntry>
						<ipcEntry kind="2" symbol="H02K0044180000" ipcLevel="A" edition="19800101" entryType="K" lang="EN" nocore="yes">
							<textBody>
								<title>
									<titlePart>
										<text>for generating ac power</text>
									</titlePart>
								</title>
							</textBody>
							<ipcEntry kind="3" symbol="H02K0044200000" ipcLevel="A" edition="19800101" entryType="K" lang="EN" nocore="yes">
								<textBody>
									<title>
										<titlePart>
											<text>by changing the polarity of the magnetic field</text>
										</titlePart>
									</title>
								</textBody>
							</ipcEntry>
							<ipcEntry kind="3" symbol="H02K0044220000" ipcLevel="A" edition="19800101" entryType="K" lang="EN" nocore="yes">
								<textBody>
									<title>
										<titlePart>
											<text>by changing the conductivity of the fluid</text>
										</titlePart>
									</title>
								</textBody>
							</ipcEntry>
							<ipcEntry kind="3" symbol="H02K0044240000" ipcLevel="A" edition="19800101" entryType="K" lang="EN" nocore="yes">
								<textBody>
									<title>
										<titlePart>
											<text>by reversing the direction of fluid</text>
										</titlePart>
									</title>
								</textBody>
							</ipcEntry>
							<ipcEntry kind="3" symbol="H02K0044260000" ipcLevel="A" edition="19800101" entryType="K" lang="EN" nocore="yes">
								<textBody>
									<title>
										<titlePart>
											<text>by creating a travelling magnetic field</text>
										</titlePart>
									</title>
								</textBody>
							</ipcEntry>
						</ipcEntry>
					</ipcEntry>
					<ipcEntry kind="1" symbol="H02K0044280000" ipcLevel="A" edition="19800101" entryType="K" lang="EN" nocore="yes">
						<textBody>
							<title>
								<titlePart>
									<text>Association of MHD generators with conventional generators</text>
									<entryReference>nuclear power plants including a MHD generator <sref ref="G21D0007020000"/></entryReference>
								</titlePart>
							</title>
						</textBody>
					</ipcEntry>
				</ipcEntry>
				<ipcEntry kind="m" symbol="H02K0047000000" ipcLevel="C" entryType="K" lang="EN" priorityOrder="40" nocore="yes">
					<textBody>
						<title>
							<titlePart>
								<text>Dynamo-electric converters</text>
							</titlePart>
						</title>
					</textBody>
					<ipcEntry kind="1" symbol="H02K0047020000" ipcLevel="A" entryType="K" lang="EN" nocore="yes">
						<textBody>
							<title>
								<titlePart>
									<text>Ac/dc converters or <u>vice versa</u></text>
								</titlePart>
							</title>
						</textBody>
						<ipcEntry kind="2" symbol="H02K0047040000" ipcLevel="A" entryType="K" lang="EN" nocore="yes">
							<textBody>
								<title>
									<titlePart>
										<text>Motor/generators</text>
									</titlePart>
								</title>
							</textBody>
						</ipcEntry>
						<ipcEntry kind="2" symbol="H02K0047060000" ipcLevel="A" entryType="K" lang="EN" nocore="yes">
							<textBody>
								<title>
									<titlePart>
										<text>Cascade converters</text>
									</titlePart>
								</title>
							</textBody>
						</ipcEntry>
						<ipcEntry kind="2" symbol="H02K0047080000" ipcLevel="A" entryType="K" lang="EN" nocore="yes">
							<textBody>
								<title>
									<titlePart>
										<text>Single-armature converters</text>
									</titlePart>
								</title>
							</textBody>
							<ipcEntry kind="3" symbol="H02K0047100000" ipcLevel="A" entryType="K" lang="EN" nocore="yes">
								<textBody>
									<title>
										<titlePart>
											<text>with booster machine on the ac side</text>
										</titlePart>
									</title>
								</textBody>
							</ipcEntry>
						</ipcEntry>
					</ipcEntry>
					<ipcEntry kind="1" symbol="H02K0047120000" ipcLevel="A" entryType="K" lang="EN" nocore="yes">
						<textBody>
							<title>
								<titlePart>
									<text>Dc/dc converters</text>
								</titlePart>
							</title>
						</textBody>
						<ipcEntry kind="2" symbol="H02K0047140000" ipcLevel="A" entryType="K" lang="EN" nocore="yes">
							<textBody>
								<title>
									<titlePart>
										<text>Motor/generators</text>
									</titlePart>
								</title>
							</textBody>
						</ipcEntry>
						<ipcEntry kind="2" symbol="H02K0047160000" ipcLevel="A" entryType="K" lang="EN" nocore="yes">
							<textBody>
								<title>
									<titlePart>
										<text>Single-armature converters, e.g. metadyne</text>
									</titlePart>
								</title>
							</textBody>
						</ipcEntry>
					</ipcEntry>
					<ipcEntry kind="1" symbol="H02K0047180000" ipcLevel="A" entryType="K" lang="EN" nocore="yes">
						<textBody>
							<title>
								<titlePart>
									<text>Ac/ac converters</text>
								</titlePart>
							</title>
						</textBody>
						<ipcEntry kind="2" symbol="H02K0047200000" ipcLevel="A" entryType="K" lang="EN" nocore="yes">
							<textBody>
								<title>
									<titlePart>
										<text>Motor/generators</text>
									</titlePart>
								</title>
							</textBody>
						</ipcEntry>
						<ipcEntry kind="2" symbol="H02K0047220000" ipcLevel="A" entryType="K" lang="EN" nocore="yes">
							<textBody>
								<title>
									<titlePart>
										<text>Single-armature frequency converters with or without phase-number conversion</text>
									</titlePart>
								</title>
							</textBody>
							<ipcEntry kind="3" symbol="H02K0047240000" ipcLevel="A" entryType="K" lang="EN" nocore="yes">
								<textBody>
									<title>
										<titlePart>
											<text>having windings for different numbers of poles</text>
										</titlePart>
									</title>
								</textBody>
							</ipcEntry>
							<ipcEntry kind="3" symbol="H02K0047260000" ipcLevel="A" entryType="K" lang="EN" nocore="yes">
								<textBody>
									<title>
										<titlePart>
											<text>operating as under- or over-synchronously running asynchronous induction machines, e.g. cascade arrangement of asynchronous and synchronous machines</text>
										</titlePart>
									</title>
								</textBody>
							</ipcEntry>
							<ipcEntry kind="3" symbol="H02K0047280000" ipcLevel="A" entryType="K" lang="EN" nocore="yes">
								<textBody>
									<title>
										<titlePart>
											<text>operating as commutator machines with added slip-rings</text>
										</titlePart>
									</title>
								</textBody>
							</ipcEntry>
						</ipcEntry>
						<ipcEntry kind="2" symbol="H02K0047300000" ipcLevel="A" entryType="K" lang="EN" nocore="yes">
							<textBody>
								<title>
									<titlePart>
										<text>Single-armature phase-number converters without frequency conversion</text>
									</titlePart>
								</title>
							</textBody>
						</ipcEntry>
					</ipcEntry>
				</ipcEntry>
				<ipcEntry kind="m" symbol="H02K0049000000" ipcLevel="C" entryType="K" lang="EN" priorityOrder="60" nocore="yes">
					<textBody>
						<title>
							<titlePart>
								<text>Dynamo-electric clutches</text>
							</titlePart>
							<titlePart>
								<text>Dynamo-electric brakes</text>
								<entryReference>electrically or magnetically actuated clutches or brakes <sref ref="F16D0027000000"/>, <sref ref="F16D0029000000"/>, <sref ref="F16D0065340000"/>, <sref ref="F16D0065360000"/></entryReference>
								<entryReference>magnetic-particle clutches <sref ref="F16D0037020000"/></entryReference>
								<entryReference>adapted for use as dynamometers <sref ref="G01L"/></entryReference>
							</titlePart>
						</title>
					</textBody>
					<ipcEntry kind="1" symbol="H02K0049020000" ipcLevel="A" entryType="K" lang="EN" nocore="yes">
						<textBody>
							<title>
								<titlePart>
									<text>of the asynchronous induction type</text>
								</titlePart>
							</title>
						</textBody>
						<ipcEntry kind="2" symbol="H02K0049040000" ipcLevel="A" entryType="K" lang="EN" nocore="yes">
							<textBody>
								<title>
									<titlePart>
										<text>of the eddy-current hysteresis type</text>
									</titlePart>
								</title>
							</textBody>
						</ipcEntry>
					</ipcEntry>
					<ipcEntry kind="1" symbol="H02K0049060000" ipcLevel="A" entryType="K" lang="EN" nocore="yes">
						<textBody>
							<title>
								<titlePart>
									<text>of the synchronous type</text>
								</titlePart>
							</title>
						</textBody>
					</ipcEntry>
					<ipcEntry kind="1" symbol="H02K0049080000" ipcLevel="A" entryType="K" lang="EN" nocore="yes">
						<textBody>
							<title>
								<titlePart>
									<text>of the collector armature type</text>
								</titlePart>
							</title>
						</textBody>
					</ipcEntry>
					<ipcEntry kind="1" symbol="H02K0049100000" ipcLevel="A" entryType="K" lang="EN" nocore="yes">
						<textBody>
							<title>
								<titlePart>
									<text>of the permanent-magnet type</text>
								</titlePart>
							</title>
						</textBody>
					</ipcEntry>
					<ipcEntry kind="1" symbol="H02K0049120000" ipcLevel="A" entryType="K" lang="EN" nocore="yes">
						<textBody>
							<title>
								<titlePart>
									<text>of the acyclic type</text>
								</titlePart>
							</title>
						</textBody>
					</ipcEntry>
				</ipcEntry>
				<ipcEntry kind="m" symbol="H02K0051000000" ipcLevel="C" entryType="K" lang="EN" priorityOrder="50" nocore="yes">
					<textBody>
						<title>
							<titlePart>
								<text>Dynamo-electric gears, i.e. dynamo-electric means for transmitting mechanical power from a driving shaft to a driven shaft and comprising structurally interrelated motor and generator parts</text>
							</titlePart>
						</title>
					</textBody>
				</ipcEntry>
				<ipcEntry kind="m" symbol="H02K0053000000" ipcLevel="C" entryType="K" lang="EN" priorityOrder="220" nocore="yes">
					<textBody>
						<title>
							<titlePart>
								<text>Alleged dynamo-electric <u>perpetua mobilia</u></text>
							</titlePart>
						</title>
					</textBody>
				</ipcEntry>
				<ipcEntry kind="m" symbol="H02K0055000000" ipcLevel="C" edition="19800101" entryType="K" lang="EN" priorityOrder="10" nocore="yes">
					<textBody>
						<title>
							<titlePart>
								<text>Dynamo-electric machines having windings operating at cryogenic temperatures</text>
							</titlePart>
						</title>
					</textBody>
					<ipcEntry kind="1" symbol="H02K0055020000" ipcLevel="A" edition="19800101" entryType="K" lang="EN" nocore="yes">
						<textBody>
							<title>
								<titlePart>
									<text>of the synchronous type</text>
								</titlePart>
							</title>
						</textBody>
						<ipcEntry kind="2" symbol="H02K0055040000" ipcLevel="A" edition="19800101" entryType="K" lang="EN" nocore="yes">
							<textBody>
								<title>
									<titlePart>
										<text>with rotating field windings</text>
									</titlePart>
								</title>
							</textBody>
						</ipcEntry>
					</ipcEntry>
					<ipcEntry kind="1" symbol="H02K0055060000" ipcLevel="A" edition="19800101" entryType="K" lang="EN" nocore="yes">
						<textBody>
							<title>
								<titlePart>
									<text>of the homopolar type</text>
								</titlePart>
							</title>
						</textBody>
					</ipcEntry>
				</ipcEntry>
				<ipcEntry kind="m" symbol="H02K0057000000" ipcLevel="C" edition="19800101" entryType="K" lang="EN" priorityOrder="230" nocore="yes">
					<textBody>
						<title>
							<titlePart>
								<text>Dynamo-electric machines not provided for in groups <mref ref="H02K0017000000" endRef="H02K0055000000"/></text>
							</titlePart>
						</title>
					</textBody>
				</ipcEntry>
			</ipcEntry>
		</ipcEntry>
	</ipcEntry>
</ipcEntries>
