|
|
| SECTION H ELECTRICITY |
| H 02 | GENERATION, CONVERSION, OR DISTRIBUTION OF ELECTRIC POWER |
| H 02 K | DYNAMO-ELECTRIC MACHINES (measuring instruments G01; dynamo-electric relays H01H 53/00; conversion of dc or ac input power into surge output power H02M 9/00; loudspeakers, microphones, gramophone pick-ups or like acoustic electromechanical transducers H04R) |
33/ | 00 | Motors with reciprocating, oscillating, or vibrating magnet, armature, or coil system (arrangements for handling mechanical energy structurally associated with motors H02K 7/00, e.g. H02K 7/06) |
33/ | 02 | . | with armature moved one way by energisation of a single coil system and returned by mechanical force, e.g. by spring |
33/ | 04 | . | . | wherein the frequency of operation is determined by the frequency of uninterrupted ac energisation |
33/ | 06 | . | . | . | with polarised armature |
33/ | 08 | . | . | . | with dc energisation superimposed on ac energisation |
33/ | 10 | . | . | wherein the alternate energisation and de-energisation of the single coil system is effected or controlled by movement of the armature |
33/ | 12 | . | with armature moving in alternate directions by alternate energisation of two coil systems |
33/ | 14 | . | . | wherein the alternate energisation and de-energisation of the two coil systems are effected or controlled by movement of the armature |
33/ | 16 | . | with polarised armature moving in alternate directions by reversal or energisation of a single coil system |
33/ | 18 | . | with coil system moving upon intermittent or reversed energisation thereof by interaction with a fixed field system, e.g. permanent magnet |
35/ | 00 | Generators with reciprocating, oscillating, or vibrating coil system, magnet, armature, or other part of the magnetic circuit (arrangements for handling mechanical energy structurally associated with generators H02K 7/00, e.g. H02K 7/06) |
35/ | 02 | . | with moving magnet and stationary coil system |
35/ | 04 | . | with moving coil system and stationary magnet |
35/ | 06 | . | with moving flux distributor, and both coil system and magnet stationary |
37/ | 00 | Motors with rotor rotating step by step and without interrupter or commutator driven by the rotor, e.g. stepping motors |
37/ | 02 | . | variable reluctance type [4] |
37/ | 04 | . | . | Rotor situated within stator [4] |
37/ | 06 | . | . | Rotor situated around stator [4] |
37/ | 08 | . | . | Rotor axially facing stator [4] |
37/ | 10 | . | permanent magnet type (H02K 37/02 takes precedence) [4] |
37/ | 12 | . | . | with stationary armature and rotating magnet [4] |
37/ | 14 | . | . | . | Magnet rotating within armature [4] |
37/ | 16 | . | . | . | . | having horseshoe armature core [4] |
37/ | 18 | . | . | . | . | homopolar type [4] |
37/ | 20 | . | . | with rotating flux distributor, the armature and magnet both being stationary [4] |
37/ | 22 | . | Damping units [4] |
37/ | 24 | . | Structural association with auxiliary mechanical devices [4] |
39/ | 00 | Generators specially adapted for producing a desired non-sinusoidal waveform |
41/ | 00 | Propulsion systems in which a rigid body is moved along a path due to dynamo-electric interaction between the body and a magnetic field travelling along the path |
41/ | 02 | . | Linear motors; Sectional motors [3] |
41/ | 025 | . | . | Asynchronous motors [3] |
41/ | 03 | . | . | Synchronous motors; Motors moving step by step; Reluctance motors (H02K 41/035 takes precedence) [3] |
41/ | 035 | . | . | Dc motors; Unipolar motors [3] |
41/ | 06 | . | Rolling motors, i.e. having the rotor axis parallel to the stator axis and following a circular path as the rotor rolls around the inside or outside of the stator |
44/ | 00 | Machines in which the dynamo-electric interaction between a plasma or flow of conductive liquid or of fluid-borne conductive or magnetic particles and a coil system or magnetic field converts energy of mass flow into electrical energy or vice versa [3] |
44/ | 02 | . | Electrodynamic pumps [3] |
44/ | 04 | . | . | Conduction pumps [3] |
44/ | 06 | . | . | Induction pumps [3] |
44/ | 08 | . | Magnetohydrodynamic (MHD) generators [3] |
44/ | 10 | . | . | Constructional details of electrodes [3] |
44/ | 12 | . | . | Constructional details of fluid channel [3] |
44/ | 14 | . | . | . | Circular or screw-shaped channel [3] |
44/ | 16 | . | . | Constructional details of the magnetic circuit [3] |
44/ | 18 | . | . | for generating ac power [3] |
44/ | 20 | . | . | . | by changing the polarity of the magnetic field [3] |
44/ | 22 | . | . | . | by changing the conductivity of the fluid [3] |
44/ | 24 | . | . | . | by reversing the direction of fluid [3] |
44/ | 26 | . | . | . | by creating a travelling magnetic field [3] |
44/ | 28 | . | Association of MHD generators with conventional generators (nuclear power plants including a MHD generator G21D 7/02) [3] |
47/ | 00 | Dynamo-electric converters |
47/ | 02 | . | Ac/dc converters or vice versa |
47/ | 04 | . | . | Motor/generators |
47/ | 06 | . | . | Cascade converters |
47/ | 08 | . | . | Single-armature converters |
47/ | 10 | . | . | . | with booster machine on the ac side |
47/ | 12 | . | Dc/dc converters |
47/ | 14 | . | . | Motor/generators |
47/ | 16 | . | . | Single-armature converters, e.g. metadyne |
47/ | 18 | . | Ac/ac converters |
47/ | 20 | . | . | Motor/generators |
47/ | 22 | . | . | Single-armature frequency converters with or without phase-number conversion |
47/ | 24 | . | . | . | having windings for different numbers of poles |
47/ | 26 | . | . | . | operating as under- or over-synchronously running asynchronous induction machines, e.g. cascade arrangement of asynchronous and synchronous machines |
47/ | 28 | . | . | . | operating as commutator machines with added slip-rings |
47/ | 30 | . | . | Single-armature phase-number converters without frequency conversion |
49/ | 00 | Dynamo-electric clutches; Dynamo-electric brakes (electrically or magnetically actuated clutches or brakes F16D 27/00, F16D 29/00, F16D 65/34, F16D 65/36; magnetic-particle clutches F16D 37/02; adapted for use as dynamometers G01L) |
49/ | 02 | . | of the asynchronous induction type |
49/ | 04 | . | . | of the eddy-current hysteresis type |
49/ | 06 | . | of the synchronous type |
49/ | 08 | . | of the collector armature type |
49/ | 10 | . | of the permanent-magnet type |
49/ | 12 | . | of the acyclic type |
51/ | 00 | Dynamo-electric gears, i.e. dynamo-electric means for transmitting mechanical power from a driving shaft to a driven shaft and comprising structurally interrelated motor and generator parts |
53/ | 00 | Alleged dynamo-electric perpetua mobilia |
55/ | 00 | Dynamo-electric machines having windings operating at cryogenic temperatures [3] |
55/ | 02 | . | of the synchronous type [3] |
55/ | 04 | . | . | with rotating field windings [3] |
55/ | 06 | . | of the homopolar type [3] |
57/ | 00 | Dynamo-electric machines not provided for in groups H02K 17/00 to H02K 55/00 [3] |
| |