| SECTION H ELECTRICITY |
| H 02 | GENERATION, CONVERSION, OR DISTRIBUTION OF ELECTRIC POWER |
| H 02 B | BOARDS, SUBSTATIONS, OR SWITCHING ARRANGEMENTS FOR THE SUPPLY OR DISTRIBUTION OF ELECTRIC POWER (basic electric elements, their assembly, including the mounting in enclosures or on bases, or the mounting of covers thereon, see the subclasses for such elements, e.g. transformers H 01 F, switches, fuses H 01 H, line connectors H 01 R; installation of electric cables or lines, or of combined optical and electric cables or lines, or other conductors for supply or distribution H 02 G) |
| Note |
| This subclass covers boards, switchyards, switchgear or their installation, or the association of switching devices with each other or with other devices, e.g. transformers, fuses, meters or distribution boards; such associations constitute substations or distribution points. |
1/ | 00 | Frameworks, boards, panels, desks, casings; Details of substations or switching arrangements [5] |
1/ | 01 | . | Frameworks [5] |
1/ | 015 | . | Boards, panels, desks; Parts thereof or accessories therefor [5] |
1/ | 03 | . | . | for energy meters [5] |
1/ | 04 | . | . | Mounting thereon of switches or of other devices in general, the switch or device having, or being without, casing |
1/ | 044 | . | . | . | Mounting through openings [5] |
1/ | 048 | . | . | . | . | Snap mounting [5] |
1/ | 052 | . | . | . | Mounting on rails [5] |
1/ | 056 | . | . | . | Mounting on plugboards [5] |
1/ | 06 | . | . | having associated enclosures, e.g. for preventing access to live parts (shutters or guards for contacts H 02 B 1/14) |
1/ | 14 | . | Shutters or guards for preventing access to contacts (shielding of isolating-contacts in withdrawable switchgear H 02 B 11/24) |
1/ | 16 | . | Earthing arrangements (earthing arrangements for substations H 02 B 5/01, for switchgear H 02 B 11/28, H 02 B 13/075; earth plates, pins, or other contacts H 01 R 4/66) [5] |
1/ | 18 | . | Disposition or arrangement of fuses (for switchgear having a withdrawable carriage H 02 B 11/26) [5] |
1/ | 20 | . | Bus-bar or other wiring layouts, e.g. in cubicles, in switchyards (installations of bus-bars H 02 G 5/00) |
1/ | 21 | . | . | Bus-bar arrangements for rack-mounted devices with withdrawable units [5] |
1/ | 22 | . | . | Layouts for duplicate bus-bar selection |
1/ | 24 | . | Circuit arrangements for boards or switchyards (devices for displaying diagrams H 02 B 15/00; service supply H 02 J 11/00) |
| Note |
| In groups H 02 B 1/26 to H 02 B 1/56, in the absence of an indication to the contrary, classification is made in the last appropriate place. [5] |
1/ | 26 | . | Casings; Parts thereof or accessories therefor (adapted for a single switch H 01 H; enclosures for cables, lines or bus-bars H 02 G; distribution, connection or junction boxes H 02 G 3/08; casings in general H 05 K) [5] |
1/ | 28 | . | . | dustproof, splashproof, drip-proof, waterproof or flameproof [5] |
1/ | 30 | . | . | Cabinet-type casings; Parts thereof or accessories therefor [5] |
1/ | 32 | . | . | . | Mounting of devices therein [5] |
1/ | 34 | . | . | . | . | Racks [5] |
1/ | 36 | . | . | . | . | . | with withdrawable units [5] |
1/ | 38 | . | . | . | Hinged covers or doors [5] |
1/ | 40 | . | . | Wall-mounted casings; Parts thereof or accessories therefor [5] |
1/ | 42 | . | . | . | Mounting of devices therein [5] |
1/ | 44 | . | . | . | Hinged covers or doors [5] |
1/ | 46 | . | . | Boxes; Parts thereof or accessories therefor [5] |
1/ | 48 | . | . | . | Mounting of devices therein [5] |
1/ | 50 | . | . | Pedestal- or pad-mounted casings; Parts thereof or accessories therefor [5] |
1/ | 52 | . | . | Mobile units, e.g. for work sites [5] |
1/ | 54 | . | Anti-seismic devices or installations (for buildings in general E 04 B 1/98) [5] |
1/ | 56 | . | Cooling; Ventilation [5] |
3/ | 00 | Apparatus specially adapted for the manufacture, assembly, or maintenance of boards or switchgear |
5/ | 00 | Non-enclosed substations; Substations with enclosed and non-enclosed equipment |
5/ | 01 | . | Earthing arrangements, e.g. earthing rods [5] |
5/ | 02 | . | mounted on pole, e.g. pole transformer substation |
5/ | 06 | . | gas-insulated [5] |
7/ | 00 | Enclosed substations, e.g. compact substations [5] |
7/ | 01 | . | gas-insulated [5] |
7/ | 06 | . | Distribution substations, e.g. for urban network (H 02 B 7/01 takes precedence) [5] |
7/ | 08 | . | . | Underground substations |
11/ | 00 | Switchgear having carriage withdrawable for isolation |
11/ | 02 | . | Details |
11/ | 04 | . | . | Isolating-contacts, e.g. mountings, shieldings (shutters or guards for isolating contacts H 02 B 1/14, H 02 B 11/24; switch contacts H 01 H; line connectors in general H 01 R) [5] |
11/ | 06 | . | . | Means for duplicate bus-bar selection (layouts for duplicate bus-bar selection H 02 B 1/22) |
11/ | 08 | . | . | Oil-tank lowering means associated with withdrawal mechanism |
11/ | 10 | . | . | Indicating electrical condition of gear; Arrangement of test sockets |
11/ | 12 | . | with isolation by horizontal withdrawal |
11/ | 127 | . | . | Withdrawal mechanism [5] |
11/ | 133 | . | . | . | with interlock (interlock for switches in general H 01 H) [5] |
11/ | 167 | . | . | truck type (H 02 B 11/127 takes precedence) [5] |
11/ | 173 | . | . | drawer type (H 02 B 11/127 takes precedence) [5] |
11/ | 18 | . | with isolation by vertical withdrawal |
11/ | 20 | . | . | having an enclosure |
11/ | 22 | . | . | . | wherein front of enclosure moves with carriage upon horizontal withdrawal subsequent to isolation |
11/ | 24 | . | Shutters or guards [5] |
11/ | 26 | . | Arrangement of fuses, resistors, voltage arresters or the like [5] |
11/ | 28 | . | Earthing arrangements [5] |
13/ | 00 | Arrangement of switchgear in which switches are enclosed in, or structurally associated with, a casing, e.g. cubicle (in association with main transformer H 02 B 5/00, H 02 B 7/00; switchgear having carriage withdrawable for isolation H 02 B 11/00) |
13/ | 01 | . | with resin casing [5] |
13/ | 02 | . | with metal casing |
13/ | 025 | . | . | Safety arrangements, e.g. in case of excessive pressure or fire due to electrical defect (for buildings in general E 04 B 1/94; devices for opening or closing safety wings E 05 F 1/00; emergency protective circuit arrangements for distribution gear, e.g. bus-bar systems, or for switching devices H 02 H 7/22) [5] |
13/ | 035 | . | . | Gas-insulated switchgear [5] |
13/ | 045 | . | . | . | Details of casing, e.g. gas tightness (gas reservoirs for switches H 01 H 33/56) [5] |
13/ | 055 | . | . | . | Features relating to the gas (selection of fluids for switches H 01 H 33/22) [5] |
13/ | 065 | . | . | . | Means for detecting or reacting to mechanical or electrical defects (for switches H 01 H 9/50, H 01 H 33/26, H 01 H 33/53) [5] |
13/ | 075 | . | . | . | Earthing arrangements [5] |
13/ | 08 | . | with stone, brick, or concrete casing |
15/ | 00 | Supervisory desks or panels for centralised control or display (desks in general A 47 B) |
15/ | 02 | . | with mimic diagrams |
15/ | 04 | . | . | consisting of building blocks |