(0)H01R:2/5:
IPC6
SECTION H - ELECTRICITY
LINE CONNECTORS; CURRENT COLLECTORS
H01R
3/6
<<   >>   H01R013/637 - H01R019/44  

13
/ 637 by fluid pressure, e.g. explosion [3]  

13
/ 639 Additional means for holding or locking coupling parts together after engagement [3]  

13
/ 64 Means for preventing incorrect coupling  

13
/ 642 by position or shape of contact members [3]  

13
/ 645 by exchangeable elements on case or base [3]  

13
/ 648 Protective earth or shield arrangements on coupling devices [3]  

13
/ 652 with earth pin, blade or socket [3]  

13
/ 655 with earth brace [3]  

13
/ 658 High frequency shielding arrangements (two-pole coaxial coupling devices specially adapted for high frequency H 01 R 17/12) [3]  

13
/ 66 Structural association with built-in electrical component  

13
/ 68 with built-in fuse  

13
/ 70 with built-in switch  

13
/ 703 operated by engagement or disengagement of coupling parts (H 01 R 13/71 takes precedence) [3]  

13
/ 707 interlocked with contact members or counterpart [3]  

13
/ 71 Contact members of coupling parts operating as switch [3]  

13
/ 713 the switch being a safety switch [3]  

13
/ 717 with built-in light bulb [3]  

13
/ 719 specially adapted for high frequency [4]  

13
/ 72 Means for accommodating flexible lead within the holder  

13
/ 73 Means for mounting coupling parts to apparatus or structures, e.g. to a wall [4]  

13
/ 74 for mounting coupling parts in openings of a panel [3]  
 

15
/ 00 Two-part coupling devices having a single pole, with or without additional protective earth connection (with a holder adapted for supporting apparatus to which its counterpart is attached H 01 R 33/02)

15
/ 08 Pin-carrying coupling parts, e.g. banana-type plug  

15
/ 10 Socket-carrying coupling parts  

15
/ 12 wherein one coupling part is secured only to a wire or cable and the other part is secured to apparatus or structure [4]  
 

17
/ 00 Two-part coupling devices having two poles, with or without additional protective earth connection; Separate parts thereof (H 01 R 19/00 takes precedence; with a holder adapted for supporting apparatus to which its counterpart is attached H 01 R 33/00)

17
/ 04 having concentrically or coaxially-arranged contacts of different diameters  

17
/ 12 specially adapted for high frequency [4]  

17
/ 18 having the contacts of each coupling part arranged in line parallel with the direction of coupling-engaging motion, e.g. telephone-jack type  
 

19
/ 00 Two-part coupling devices having two poles, with or without additional protective earth connection, and with two current-carrying pins, blades, or analogous contacts, having their axes parallel to each other and slidingly co-operating with separate sockets, clips, or analogous counter-contacts; Separate parts thereof (with a holder adapted for supporting apparatus to which its counterpart is attached H 01 R 33/05 )

19
/ 04 Coupling parts carrying two pins, blades, or analogous contacts, and secured only to wires or cables [4]  

19
/ 06 with additional earth or shield contact [4]  

19
/ 08 the additional contact being formed as pin or socket contact [4]  

19
/ 16 Coupling parts carrying two pins, blades, or analogous contacts, and secured to apparatus or structures, e.g. to a wall [4]  

19
/ 18 with additional earth or shield contact [4]  

19
/ 20 the additional contact formed as pin or socket contact [4]  

19
/ 28 Coupling parts carrying two sockets, clips, or analogous counter-contacts, and secured only to wires or cables [4]  

19
/ 30 with additional earth or shield contact [4]  

19
/ 32 the additional contact formed as pin or socket contact [4]  

19
/ 40 Coupling parts carrying two sockets, clips, or analogous counter-contacts, and secured to apparatus or structures, e.g. to a wall [4]  

19
/ 42 with additional earth or shield contact [4]  

19
/ 44 the additional contact formed as pin or socket contact [4]  

<< >>