(0)G08B:2/2:
IPC6
SECTION G - PHYSICS
SIGNALLING OR CALLING SYSTEMS; ORDER TELEGRAPHS; ALARM SYSTEMS
G08B
3/3
<<   >>   G08B015/00 - G08B029/28  

15
/ 00 Identifying, scaring, or incapacitating burglars, thieves, or intruders, e.g. by explosives (burglar traps, or the like, on safes E 05 G 5/02)

15
/ 02 with smoke, gas, or coloured or odorous powder or liquid  
 

17
/ 00 Fire alarms; Alarms responsive to explosion (temperature-responsive elements G 01 K)

17
/ 02 Mechanical actuation of the alarm, e.g. by the breaking of a wire  

17
/ 04 Hydraulic or pneumatic actuation of the alarm, e.g. by change of fluid pressure  

17
/ 06 Electric actuation of the alarm, e.g. using a thermally-operated switch (thermally-operated electric switches per se H 01 H 37/00)  

17
/ 08 Actuation involving the use of explosive means  

17
/ 10 Actuation by presence of smoke or gases  

17
/ 103 using a light emitting and receiving device [5]  

17
/ 107 for detecting light-scattering due to smoke [5]  

17
/ 11 using an ionisation chamber for detecting smoke or gas (vacuum gauges making use of ionisation effects G 01 L 21/30; gas analysis by investigating the ionisation G 01 N 27/62 ) [5]  

17
/ 113 Constructional details (discharge tubes for measuring pressure of introduced gas, or for detecting presence of gas, in general H 01 J 41/02) [5]  

17
/ 117 by using a detection device for specific gases, e.g. combustion products, produced by the fire (G 08 B 17/103, G 08 B 17/11 take precedence; investigating or analysing gases in general G 01 N, e.g. by using electric means G 01 N 27/00) [5]  

17
/ 12 Actuation by presence of radiation or particles, e.g. of infra-red radiation, of ions  
 

19
/ 00 Alarms responsive to two or more different undesired or abnormal conditions, e.g. burglary and fire, abnormal temperature and abnormal rate of flow

19
/ 02 Alarm responsive to formation or anticipated formation of ice (indicating weather conditions G 01 W 1/00)  
 

21
/ 00 Alarms responsive to a single specified undesired or abnormal operating condition and not elsewhere provided for
 

23
/ 00 Alarms responsive to unspecified undesired or abnormal conditions
 

25
/ 00 Alarm systems in which the location of the alarm condition is signalled to a central station, e.g. fire or police telegraphic systems

25
/ 01 characterised by the transmission medium [5]  

25
/ 04 using a single signalling line, e.g. in a closed loop [5]  

25
/ 06 using power transmission lines (systems in general for transmission of information via power distribution lines H 04 B 3/54) [5]  

25
/ 08 using communication transmission lines (telephonic communication systems combined with alarm systems H 04 M 11/04) [5]  

25
/ 10 using wireless transmission systems [5]  

25
/ 12 Manually actuated calamity alarm transmitting arrangements [5]  

25
/ 14 Central alarm receiver or annunciator arrangements [5]  
 

26
/ 00 Alarm systems in which substations are interrogated in succession by a central station
 

27
/ 00 Alarm systems in which the alarm condition is signalled from a central station to a plurality of substations
 

29
/ 00 Checking or monitoring of signalling or alarm systems; Prevention or correction of operating errors, e.g. preventing unauthorised operation

29
/ 02 Monitoring continuously signalling or alarm systems [5]  

29
/ 04 Monitoring of the detection circuits [5]  

29
/ 06 Monitoring of the line circuits, e.g. signalling of line faults (testing or locating faults in cables or lines in general G 01 R 31/02, G 01 R 31/08) [5]  

29
/ 08 Signalling of tampering with the line circuit [5]  

29
/ 10 Monitoring of the annunciator circuits [5]  

29
/ 12 Checking intermittently signalling or alarm systems [5]  

29
/ 14 checking the detection circuits [5]  

29
/ 16 Security signalling or alarm systems, e.g. redundant systems [5]  

29
/ 18 Prevention or correction of operating errors (G 08 B 29/02, G 08 B 29/12 take precedence) [5]  

29
/ 20 Calibration, including self-calibrating arrangements [5]  

29
/ 22 Provisions facilitating manual calibration, e.g. input or output provisions for testing; Holding of intermittent values to permit measurement [5]  

29
/ 24 Self-calibration, e.g. compensating for environmental drift or ageing of components [5]  

29
/ 26 by updating and storing reference thresholds [5]  

29
/ 28 by changing the gain of an amplifier [5]  
 

31
/ 00 Predictive alarm systems characterised by extrapolation or other computation using updated historic data [5]

 

 

 


<< >>
1 3 3